29
Cleaning and Maintenance
The hydro wizard operates largely maintenance free. Should it increase
its energy consumption the cause is usually calcium deposits on the
bearings. Depending on the water chemistry this effect can vary
greatly.
To clean the bearings they must be submerged in a vinegar solution.
Mix 500ml of white vinegar with 10 l of water in a bucket.
Set the pump in flow mode at 2% power.
Fully submerge the pump in the solution.
Leave the pump running for one hour.
Now discard the solution and run the pump one more hour in
clean fresh water.
This protocol should be performed once a year as a precaution.
Frequently check the condition of the cable to make sure that
movement or animals have not damaged it.
General Cleaning
Remove plants or other objects that have been sucked onto the intake
at least once a week (or if needed more often). Sediment that has
settled on the housing can be removed with a soft brush.
Do not clean the pump, or parts in the dish washer. The
plastics are not dish washer safe.