Panta Rhei Hydro Wizard ECM 63 Скачать руководство пользователя страница 19

 

19 

Operation 

Initial start up 

After the hydro wizard is plugged in for the first time you must set the 
language, time and date.  
  

 

These settings can be changed later in the info menu 

 

Selecting the mode 

Select the desired mode in the main menu, in the change mode 
screen.  

 

Changing  the  mode  on  the  screen  will  change  it  without 
confirmation.  The  mode  will  operate  with  the  currently  active 
settings 

 

In case of a power failure the pump will not restart on its own. The 
settings  are  saved  and  will  be  available  after  a  power  failure. 
When power is re-established the hydro wizard will be stopped. 

 

Flow mode 

The  flow  mode  is  used  to  make  a  steady  flow  in  the  tank.  After  
selecting  the  flow  mode  select  the  strength  of  the  flow  (in  %)  in  
the  settings  menu,  or  the  quick  change  field  in  the  info  menu.  If  the 
pump  is  stopped    (blinking    “STOP”    field    in    the    info    menu)    the  
settings    will   take effect after  the  Stop  button  is  pressed  again.  If  not 
they  will take  effect  RIGHT  AWAY.  It is  best  to  change  the flow  while 
the  pump  is  running,  and  it  is  easier  to  observe  the  changes  in  the 
aquarium.  You  can  stop  the   pump    by    selecting    a    flow    of    0%   or  
pushing  the  STOP  field  in  the menu or info screen.   

 
 

Always increase the flow slowly and carefully observe the changes 
for some time

 

 

 

 
The  flow mode  is  selected  as  a default  for  the  first  time  you 
are using the pump, or in case of a reset. At 1% the motor is 
already running at 500 revolutions a minute, a lower value is 
not possible. 

 

 

 

Содержание Hydro Wizard ECM 63

Страница 1: ...hydro wizard ECM63 User Manual...

Страница 2: ...2 Panta Rhei GmbH Pappelweg 4 30179 Hannover Telefon 49 0 5130 60 957 27 Fax 49 0 5130 60 957 26 MAIL info panta rhei aquatics de WEB http www panta rhei aquatics de Version 429789b Stand 12 12 13...

Страница 3: ...o wizard 13 The Information Screen 13 The Menu Screen 15 The make changes screen 16 Menu structure 17 Operation 19 Flow mode 19 Wave mode 20 Connecting to the Panta Rhei BUS 22 Cleaning function 27 Th...

Страница 4: ...4 For your safety please read this document before using this product for the first time Keep these operation instructions so you can have access to this information at all times...

Страница 5: ...with limited physical sensory or mental capacities or insufficient experience and or insufficient knowledge Unless they are supervised by a person responsible for their safety and are instructed how t...

Страница 6: ...ariants with magnet mount The magnets included in this box are many times more powerful that conventional household magnets Do not bring these magnets close to devices that are sensitive to magnetic f...

Страница 7: ...ater is a basic function This eliminates dead zones in the water With the controller it is possible to generate wave simulations in which both wave height and length can be adjusted The pump can simul...

Страница 8: ...supply Function The movement of the impeller generates an area of low pressure which pulls the water from the back through the basket and pushes it out the front over the fins of the stator 1 2 3 4 5...

Страница 9: ...mp is unplugged before placing it in the aquarium Please attach the pump only by the attachment points designed for this purpose Either use the included magnet foot bracket or the three M5 threaded ho...

Страница 10: ...ly submerged in water The pump must be installed deep enough to ensure it will not draw air from the surface Remember that in wave mode the water level will change The pump can be installed directly a...

Страница 11: ...r flow in your aquarium are plants sucked in decoration knocked over If needed reposition the pump or reduce the output power Choosing the wrong wave length resonance in any aquarium can cause severe...

Страница 12: ...plug The stator is attached to the front of the housing with a bayonet lock To remove it spin it clockwise and pull it forward To change the impeller use an Allan key metric 4mm Hold the impeller wit...

Страница 13: ...explain the most important fields of the touch screen Warning for maintenance ALWAYS disconnect the hydro wizard from the power grid Do not use any of the following stop functions to perform maintena...

Страница 14: ...l restart the hydro wizard When shipped the hydro wizard will arrive in Stop mode after it has been plugged in The MENU field will call up the main Menu The center of the screen will allow you to quic...

Страница 15: ...arrow at the right enters that submenu the arrow button on the left returns to the menu above To confirm this selection this item will get bigger to make them more visible Figure 5 confirmed return bu...

Страница 16: ...below are buttons to increase or decrease the number by the smallest step possible On the right side is a field that can be used like wheel it is used to increase or decrease the value smoothly with...

Страница 17: ...e 7 menu structur Mode Info Quick access Duration Start Manuel Automatic Language Date Time Turn Tool Tip Active Password Main menu Settings Pause Cleaning Unit Password Depens on mode Restart Reset N...

Страница 18: ...9 settings in wave mode enter time Figure 10 settings in profil mode Flow Settings Current A Settings Current B Time A Time B Time B A Find frequency Time A B Phase delay New interval Settings Interva...

Страница 19: ...make a steady flow in the tank After selecting the flow mode select the strength of the flow in in the settings menu or the quick change field in the info menu If the pump is stopped blinking STOP fi...

Страница 20: ...ween two or three different flows These flows can be varied from 1 to 100 with the parameters flow A and flow B The Parameters time A and time B are used to select the duration of each action The para...

Страница 21: ...r stop the wave or flow mode automatically This allows waves or flow to be controlled individually for different time intervals To best understand the function of the wave and flow modes please read t...

Страница 22: ...Remove the protective caps fro the CAN sockets 2 Connect one power supply to the next as shown in the figure below Each socket can be used for in or out so the order in which they are connected is not...

Страница 23: ...ve it will take the settings of the Master automatically The information screen will display Slave and the settings transmitted by the Master If the connection is interrupted the unit will continue to...

Страница 24: ...wizard In this example the parallel usage of two hydro wizard are used to generate a stronger current or wave The Slave setting is used to achieve this pattern Requiered settings hydro wizard A Connec...

Страница 25: ...Settings hydro wizard A Connection Master Mode Welle Settings Current A 100 Settings Current B 1 Settings Time A 2s Settings Time B 2s hydro wizard B Vernetzung Sync Modus Wave Settings Current A 100...

Страница 26: ...while hydro wizard B will run from noon until midnight To achieve this the time must be synchronized in the SYNC mode Required Settings hydro wizard A Connection Master Mode Profile Settings New inte...

Страница 27: ...The Pause Feed timer The pause feed timer stops the hydro wizard and automatically resumes the programmed settings after an elapsed time i e during feeding The feed timer function can be reached from...

Страница 28: ...on is used to turn the orientation of the display by 180 degrees The menu selection reset returns all settings to the factory default The menu item restart is used to determine the action after power...

Страница 29: ...submerge the pump in the solution Leave the pump running for one hour Now discard the solution and run the pump one more hour in clean fresh water This protocol should be performed once a year as a p...

Страница 30: ...entered in the controller pump suddenly stops the impeller is blocked unplug the pump remove blockage power failure check GFI house fuse the controller is in a change settings mode read the manual for...

Страница 31: ...31 Disposal and Enviroment The pump should not be discarded with the regular trash it should be disposed of according to local regulations please check with your local authority RICHTLINIE 2002 96 EG...

Страница 32: ...nt Warranty exclusions The following are not covered by this warranty use for other than the intended purpose accidents or changes to the hardware or software unauthorized modifications an unsuitable...

Страница 33: ...Plug AUS ARG 429751 no pic Plug JAP 429752 Titanium screw 4x M5x16 429822 Titanium screw M4x10 428201 Impeller 428200 Adapter ring 429262 Quick change mount requires adatper ring or adjustable breake...

Страница 34: ...0 60Hz max energy consumption 120 Watt min revolutions 500 R min max revolutions 1800 R min max output 51 000 L h max liquid velocity 3 3 m s axial force 25 N max depth 2 5 m limited by cable weight m...

Страница 35: ...35 Dimensions all dimensions in mm Mount dimensions Do not cover the holes in the back of the hydro wizard Use adapter ring 429262 or the adjustable breaket 429786 from accessories page 33...

Страница 36: ...Enjoy your new hydro wizard...

Отзывы: