20
Wave mode
The wave mode is used to generate waves in the aquarium. After
changing into the wave mode you can change the parameters in the
settings menu or the quick change menu from the info screen. If the
pump is stopped (STOP button in the info or menu screen is blinking)
your settings will take effect when the pump is restarted after you push
the STOP button again. Otherwise they will take effect immediately.
The hydro wizard® will generate waves by changing between two or
three different flows. These flows can be varied from 1% to 100% with
the parameters "flow A" and "flow B".
The Parameters "time A" and "time B" are used to select the duration
of each action.
The parameter "time A-B" defines the duration of the interval when the
current changes from "flow A" to "flow B".
The parameter "phase delay" is used when several power supplies and
pumps are working in sync. It defines the delay in which the units wave
is started later than the MASTER unit.
More information on connection several units can be found
under the chapter: network
figure 11: information screen in wave mode
Flow B
Flow A
Current flow
Time B-A
Time A-B
Time A
Time B
phase