T6
Optional sensor,
undefined(optional)
T7
Temperature for thermal energy
measurement (optional)
HR
Back-up heating
System 14: Solar system with 1 collector field, swimming pool heating
Description:
The controller calculates the temperature difference between collector sensor T1 and
swimming pool sensor T2. If the difference is larger than or identical to the adjusted
switch-on temperature difference, then solar circulation pump (R1) will be switched on, and
swimming pool will be loaded until the switch-off temperature difference or the maximum
swimming pool temperature is reached.
Sensor Description
Relay Description
T0
Optional sensor, undefined
R1
Solar circulation pump
T1
Temperature of collector
R2
OPARR
(
Parallel relay
)
T2
Temperature of swimming pool
R3
SFB
(
Solid fuel boiler
)
T3
Optional sensor, undefined
R4
1.TIMER (Timer heating)
2.Thermal energy transferring
T4
Temperature of thermostat
(optional)
R5
1. Thermostat function
T5
Optional sensor, undefined
T6
Optional sensor, undefined
T7
Temperature for thermal energy
measurement (optional)
HR
Back-up heating