Operation manual of solar controller SR658
Page 82 of 105
Menu structure
Main menu
Submenu
Default set
Adjust
range
Description
MAN
Manual mode
R1
OFF
ON/OFF
R1 On and OFF
R2
OFF
ON/OFF
R2 On and OFF
R3
OFF
ON/OFF
R3 On and OFF
R4
OFF
ON/OFF
R4 On and OFF
R5
OFF
ON/OFF
R5 On and OFF
HR
OFF
ON/OFF
HR On and OFF
Function set:
►Press “SET” button to select menu “MAX”,
►Press “SET” button, “R1 OFF” displays on the screen
►Press “SET” button, “OFF” blinks on the scr1en
►Press “↑”, “↓” button, to activate this function, “R1 ON” displays on the screen
►Press “SET” or “ESC” button, to confirm the setting
►Press “↑” button, “R2” displays, doing like above steps, to activate manual mode of relay
R2, R3, R4, R5, HR
(
19
)
BLPR Block protection function
Function description
:
for protect the pumps against blocking after standstill, the controller is equipped with a
blocking protection function. This function switches on the relays one after another every day
at 12:00 a.m. and runs every relay for 10 s at 100 % speed.