background image

DP

O

E™

 Power System User Manual 

 

Part Number: PN380C 

 

 

  

ii

 

 

SAFETY WARNING 

The 

DP

O

E™

 

Power Patch Panel Power System is for use in restricted access locations only. It is suitable 

for mounting on concrete or other non-combustible surfaces. 
  
Always observe standard safety precautions during installation, operation and maintenance of this 
product. Read the installation instructions before performing any work. Only a competent technician who 
is aware of the hazards involved should carry out adjustment, maintenance or repairs. Do not work on the 
system or connect or disconnect cables during periods of lightning activity. Ultimate disposal of this 
product should be handled according to all national laws and regulations. 
 

WARNING: 

HAZARDOUS VOLTAGE AND ENERGY LEVELS ARE PRESENT THAT CAN 
PRODUCE SERIOUS SHOCKS AND BURNS

. Only authorized, qualified, and 

trained personnel should attempt to work on this equipment.   

 

CAUTION: 

The plug end of the cords used to connect to the Alternating Current (AC) source 
are considered to be the primary disconnect means, and reasonable access must 
be given to the plug and receptacle area. The receptacle must be fed with a 
breaker or fuse according to the instructions in this guide. 

 

CAUTION: 

ALL RECTIFIERS EMPLOY INTERNAL DOUBLE POLE/NEUTRAL FUSING. 

 

FCC Compliance Statement 

This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: 
 
1.  This device may not cause harmful interference, and 
2.  This device must accept any interference received, including interference that may cause undesired 

operation. 

 

WARNING: 

Changes or modifications to this unit not expressly approved by the party 
responsible for the compliance could void the user's authority to operate this 
equipment. 

 
WARRANTY 

Unless otherwise specified, all products presented in this user's guide are warranted against defects in 
material and workmanship for a period of one year from the date of invoice by 

PANDUIT

® Corp. to the 

initial purchaser. During the warranty period 

PANDUIT

 Corp. will, at its discretion, either repair or replace 

products that prove to be defective. For warranty service or repair, the product claimed to be defective 
must be returned to a service facility designated by 

PANDUIT

 Corp. Buyer shall prepay all the shipping 

charges to 

PANDUIT

 Corp. and if, in the opinion of 

PANDUIT

 Corp., the product is defective, 

PANDUIT 

Corp. shall pay shipping charges to return the product to Buyer. However, Buyer shall pay all shipping 
charges, duties and taxes for products returned to 

PANDUIT

 Corp. from another country. 

PANDUIT

 Corp. 

warrants that its firmware designed by 

PANDUIT

 Corp. for use with an instrument will execute its 

functions when properly installed on that instrument. 

PANDUIT

 Corp. does not warrant that the operation 

of the instrument or the firmware will be uninterrupted or error-free. 
 
The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by 
Buyer (buyer-supplied firmware or interfacing unauthorized modification or misuse, operation outside of 
the environmental specifications for the product, or improper site preparation or maintenance).  No other 
warranty is expressed or implied. 

PANDUIT 

Corp. specifically disclaims the implied warranties of 

merchantability and fitness for a particular purpose.   
 
 

Содержание DPOE PN380C

Страница 1: ...ding or otherwise without written permission from PANDUIT No patent liability is assumed with respect to the use of the information contained herein Although every precaution has been taken in the pre...

Страница 2: ...ndesired operation WARNING Changes or modifications to this unit not expressly approved by the party responsible for the compliance could void the user s authority to operate this equipment WARRANTY U...

Страница 3: ...direct indirect special incidental or consequential damages whether based on contract tort or other legal theory Unless otherwise specified by PANDUIT Corp opening this product by unauthorized personn...

Страница 4: ...cuit and Current Limit 11 TROUBLESHOOTING 12 Figures Figure 1 Top View of Power Chassis with Power Rectifiers Installed 1 Figure 2 Individual AC Feed Wiring Architecture 4 Figure 3 DC Wire Diagram 5 F...

Страница 5: ...0C v Table 4 Recommended AC Circuit Breaker and Wire Sizes 4 Table 5 Minimum Recommended DC AWG for 90 C Cabling for Unprotected Outputs 6 Table 6 Recommended Torque Settings 7 Table 7 PANDUIT Corp Co...

Страница 6: ...an However 120 watts may not be enough power to support all the Powered Devices PD connected to the panel or powered midspan In these cases or in cases of multiple DPOE Power over Ethernet Systems a l...

Страница 7: ...its are shown in Table 5 Minimum Recommended DC AWG for 90 C Cabling for Unprotected Outputs respectively In practice loop voltage drop considerations will usually dictate larger than minimum safe wir...

Страница 8: ...m and typical British Thermal Units per hour BTU hr of heat dissipated from each rectifier The maximum is calculated at 90 VAC and typical is calculated at 230 VAC Table 3 Heat Dissipation Part Number...

Страница 9: ...utput Wiring Sizing There are two main considerations for sizing DC wire ampacity and voltage drop Ampacity refers to the safe current carrying level as specified by U S based organizations such as Un...

Страница 10: ...tion may be used as a battery input or as an unfused bulk output The connections require a terminal lug 1 4 single hole lug with a max tongue width of 0 63 or less such as PANDUIT part LCA4 14 L Size...

Страница 11: ...e not attached to the power harness Contact PANDUIT Technical Support for more information about connecting the redundant B Feed power PANDUIT part DPOEPWRDUAL should be used for redundant powering op...

Страница 12: ...System note any physical package damage that could indicate potential damage to the contents After removing the DPOE Power System from the boxes and packing material inspect for shipping and or other...

Страница 13: ...the DPOE Power System chassis with mounting screws in the front an optional rack mount shelf may be installed underneath the chassis on the backside of the rack to alleviate potential sagging of the...

Страница 14: ...Figure 8 Chassis Rear View AC Connections 4 40 Screws Figure 9 Securing Cord Bracket to Chassis DC Output DC connections are accomplished via the rear terminal blocks and bulk output connection as sh...

Страница 15: ...re available from PANDUIT Corp The bulk output terminals feature a break off plastic piece to prevent inadvertent contact with the terminals If using the bulk DC output feature carefully break off eac...

Страница 16: ...the backplane While pressing the latch button down use the latch handle to gently ease the rectifier into the rear connector When the rectifier is properly seated releasing the latch button will hold...

Страница 17: ...rs are properly mated Table 8 Troubleshooting Alarm Problem Possible Solution DC OK LED is extinguished This rectifier has stopped outputting power Rectifier failed Replace this unit AC OK and all LED...

Отзывы: