AC Input 

Slip the cord bracket around each cord (

PANDUIT

 part # CORD-****), as shown in 

Figure 7: Cord 

Bracket

.  Plug the cord into the proper receptacle on the back of the chassis (See 

 

Figure 8: Chassis (Rear View) - AC 

Connections), then secure the cord bracket to the chassis using the 

provided screws (See 

Figure 9: Securing Cord Bracket to Chassis

).

 

 

 

Cord 
Bracket 

Securing 
Screw 

 

Figure 7: Cord Bracket 

 

 

 

Figure 8: Chassis (Rear View) - AC Connections 

 

 

#4-40 Screws 

 

Figure 9: Securing Cord Bracket to Chassis 

 
DC Output 

DC connections are accomplished via the rear terminal blocks and bulk output connection as shown in 

Figure 12: Chassis (Rear View) - DC Connections

. GMT-fused connections are accomplished via the 

rear compression screw terminal block that will accept wires sizes up to 12 AWG. If a fuse is not in 
corresponding slot, then place wire in output and corresponding return, and compress the screws to 4 in-
lbs. Place a fuse into the corresponding position into the fuse holder as shown in 

Figure 10: Chassis 

(Front View) - GMT fuse holder

.   

 

 

 

 

 

9

 

 

Содержание DPOE PN380C

Страница 1: ...ding or otherwise without written permission from PANDUIT No patent liability is assumed with respect to the use of the information contained herein Although every precaution has been taken in the pre...

Страница 2: ...ndesired operation WARNING Changes or modifications to this unit not expressly approved by the party responsible for the compliance could void the user s authority to operate this equipment WARRANTY U...

Страница 3: ...direct indirect special incidental or consequential damages whether based on contract tort or other legal theory Unless otherwise specified by PANDUIT Corp opening this product by unauthorized personn...

Страница 4: ...cuit and Current Limit 11 TROUBLESHOOTING 12 Figures Figure 1 Top View of Power Chassis with Power Rectifiers Installed 1 Figure 2 Individual AC Feed Wiring Architecture 4 Figure 3 DC Wire Diagram 5 F...

Страница 5: ...0C v Table 4 Recommended AC Circuit Breaker and Wire Sizes 4 Table 5 Minimum Recommended DC AWG for 90 C Cabling for Unprotected Outputs 6 Table 6 Recommended Torque Settings 7 Table 7 PANDUIT Corp Co...

Страница 6: ...an However 120 watts may not be enough power to support all the Powered Devices PD connected to the panel or powered midspan In these cases or in cases of multiple DPOE Power over Ethernet Systems a l...

Страница 7: ...its are shown in Table 5 Minimum Recommended DC AWG for 90 C Cabling for Unprotected Outputs respectively In practice loop voltage drop considerations will usually dictate larger than minimum safe wir...

Страница 8: ...m and typical British Thermal Units per hour BTU hr of heat dissipated from each rectifier The maximum is calculated at 90 VAC and typical is calculated at 230 VAC Table 3 Heat Dissipation Part Number...

Страница 9: ...utput Wiring Sizing There are two main considerations for sizing DC wire ampacity and voltage drop Ampacity refers to the safe current carrying level as specified by U S based organizations such as Un...

Страница 10: ...tion may be used as a battery input or as an unfused bulk output The connections require a terminal lug 1 4 single hole lug with a max tongue width of 0 63 or less such as PANDUIT part LCA4 14 L Size...

Страница 11: ...e not attached to the power harness Contact PANDUIT Technical Support for more information about connecting the redundant B Feed power PANDUIT part DPOEPWRDUAL should be used for redundant powering op...

Страница 12: ...System note any physical package damage that could indicate potential damage to the contents After removing the DPOE Power System from the boxes and packing material inspect for shipping and or other...

Страница 13: ...the DPOE Power System chassis with mounting screws in the front an optional rack mount shelf may be installed underneath the chassis on the backside of the rack to alleviate potential sagging of the...

Страница 14: ...Figure 8 Chassis Rear View AC Connections 4 40 Screws Figure 9 Securing Cord Bracket to Chassis DC Output DC connections are accomplished via the rear terminal blocks and bulk output connection as sh...

Страница 15: ...re available from PANDUIT Corp The bulk output terminals feature a break off plastic piece to prevent inadvertent contact with the terminals If using the bulk DC output feature carefully break off eac...

Страница 16: ...the backplane While pressing the latch button down use the latch handle to gently ease the rectifier into the rear connector When the rectifier is properly seated releasing the latch button will hold...

Страница 17: ...rs are properly mated Table 8 Troubleshooting Alarm Problem Possible Solution DC OK LED is extinguished This rectifier has stopped outputting power Rectifier failed Replace this unit AC OK and all LED...