AT-OME-MS52W
93
Configuration and Management Interfaces
Click these button to test CEC functionality over HDMI and HDBaseT. Click the
On
button to send the power-on
command to the display device. Click the
Off
button to send the power-off command to the display device.
CEC Commands
Relay
Trigger I/O
Enable Momentary Relay
When enabled, the relay is set to momentary. The default setting is disabled (latch). Use a 48 V DC relay with no
more than 1 A current draw. This feature is disabled, by default. Refer to
for wiring information.
Relay Pulse Duration
Click this drop-down list to select the desired pulse duration for the relay. Some devices may require different time
intervals, to recognize a state change. Range: 1 to 10 seconds.
This section defines how the
TRIGGER
port will respond to varying voltage levels when, for example, used with an
occupancy sensor. Either or both of the following conditions can be enabled or disabled.
Enable Trigger On
Check this box to power-on the system when the occupancy sensor detects a presence in the room. If the
Enable
Trigger Off
is not checked (enabled), hen the system power will remain on when the room is unoccupied.
Enable Trigger Off
Check this box to power-off the system when the occupancy sensor detects no presence in the room.