23
U S E R M A N U A L
Pandora
RMD-5M Relay Module
** Total current of relays R3+R4+R5
should not exceed 40А
*** For DXL 1920L/1930L systems
* For remote start implementation
with Start/Stop button
3 6
5
2
1 4
+ 12V
Starter
CH10***
Bypass
CH9***
NO blocking
/NC blocking
CH6***
ACC/
Brake pedal*
CH7***
Ignition
/Start/Stop button*
CH8***
R4
R5
R3
R2
R1
R1
R2
R3
R4
R5
20A
**
20A
**
20A
**
20A
20A
Relay
module
Brown
Yellow
Orange
Green/Red
Blue/Red
40А
Blue
Blue/Black
Green
Green/Black
Red
Brown
(–)
Yellow
(–)
Orange
(–)
Green
(–)
Blue
(–)
Red
(+)
• Wire «4» (Green) (CH9)
Factory setting is “Bypass“. Output activates during remote or automatic
engine start. A negative output of additional channel with maximum load current 200mA. This output
is multipurpose, it can operate as input or output in accordance with selected logic
• Wire «5» (Yellow) (CH10)
Factory setting is “Starter“. This output is used to switch on starter of
the car. A negative output of additional channel with maximum load capacity 200mA. This output is
multipurpose, it can operate as input or output in accordance with selected logic.
• Wire «6» (Red)
— relay module power supply 12V.
Х7 Socket (Multifunction channels)
Use this socket when implementing bypass of original immobilizer using IMMO-KEY1 and IMMO-KEY2
multifunctional channels. Make connections in accordance with installation scheme. The settings of the
socket are available in AlarmStudio. Disconnect the system from power supply after changing the settings.
PROGRAMMING THE SYSTEM
Entering programming menu
To change the system settings or program the system using a computer or
VALET
button, the
system should be in programming mode. Enter programming mode by entering “Service PIN-code“
(factory preset is 1-1-1-1). PIN-code should be entered using external or located on the base unit
VALET
button. The input is indicated by flashes of external or located on the base unit
LED
indicator. You can
enter the code only if the base unit is powered form USB socket or from external power supply, the
ignition is switched off, the system is disarmed and maintenance mode is switched off.
If there is no “Service PIN-code“, you can enter programming mode using the “Secret PIN-code“
written on the owner’s card.
Entering PIN-code:
• Enter the first digit of the code using
VALET
button. Press the button a number of times, equals
to the first digit. Pauses between presses should not exceed 1 second. Each pressing will be
confirmed with an orange
LED
indicator flash. A Pause for more than 1 second and a red
LED
indicator flash confirm the input of the first digit. Then you can enter the next digit.
• Enter the second digit of the code using
VALET
button. Press the button a number of times,
equals to the second digit. Pauses between presses should not exceed 1 second. Each pressing
will be confirmed with an orange
LED
indicator flash. A Pause for more than 1 second and a red