User Manual For Cyclone LC Programmers
19
Figure 3-2: Cyclone LC Right Side View
3.5
Cyclone System Power
The
Cyclone LC
programmer requires a regulated 6V DC Center Positive power supply with 2.5/
5.5mm female plug. Cyclones derive power from the Power Jack located on the right end of the
unit. The location of Cyclone System Power is shown in
.
3.6
RS232 Communication (Serial Port)
The
Cyclone LC
provides a DB9 Female connector to communicate with a host computer through
the RS232 communication (115200 Baud, 8 Data bits, No parity, 1 Stop bit). The location of the
Serial Port is shown in
.
3.7
Ethernet Communication
The
Cyclone LC
provides a standard RJ45 socket to communicate with a host computer through
the Ethernet Port (10/100 BaseT). The location of the Ethernet Port is shown in
.
3.8
USB Communications
The
Cyclone LC
provides a USB connector for Universal Serial Bus communications between the
Cyclone and the host computer. The
Cyclone LC
is a USB 2.0
Full-Speed
compliant device. The
location of the USB Port is shown in
3.9
Electromechanical Relays
Inside the
Cyclone LC
programmer, two electromechanical relays are used to cycle target power.
The specifications of the relays are as following:
Maximum switched power:
30W or 125 VA
Maximum switched current:
1A
Maximum switched voltage:
150VDC or 300VAC
UL Rating:
1A at 30 VDC
1A at 125 VAC
PEmicro only recommends switching DC voltages up to 24 Volts.
Содержание Cyclone LC Series
Страница 1: ...Cyclone LC Programmers User Manual...
Страница 8: ...17 6 Debug Ports CYCLONE LC UNIV 149 17 7 International Shipping 149 17 8 Compliances Standards 149...
Страница 41: ...User Manual For Cyclone LC Programmers 41 Figure 5 2 Main Menu Structure...
Страница 134: ...User Manual For Cyclone LC Programmers 134 4 Click the Add New License button Figure 13 2 Add New License Button...