User Manual For Cyclone LC Programmers
106
1 : Divide by 4 (usually and if applicable)
9.2.2.11.4 :BAUD n
Sets the baud rate to n. Serial port connection only If :BAUD is specified, include :FORCEPASS
followed by :SECURITYCODE.
9.2.2.11.5 :FORCEPASS
Specifies that security should be passed on startup of the software instead of waiting for an EM
(Erase Module) command. The :SECURITY code command must also be provided.
9.2.2.11.6 :SECURITYCODE hh hh hh hh hh hh hh hh
Specifies the 8 bytes of security code to use at startup which correspond to the addresses $FFF6-
$FFFD of the target HC08 device. The parameter for this is a string containing 8 bytes of data in
HEX separated by white spaces.
9.2.2.11.7 :DEVICETYPE string
Specifies the target device family. As an example, the device type for a 68HC908KX8 would be
KX. The allowed device type values are:
AB,AP,AS,AT,AZ,BD,EY,GP,GR,GR4/8,GT,GZ,JB12,JB16, JB1/8,JG,JK,JL,JR,JW,KX,LB,LD,
LJ,LK,LT,LV,MR4/8,MR16/32,QB,QC,QL,QT,QY,RF,RK,SR
9.2.2.12 Connection Related - STMicroelectronics’ STM8 Processors
9.2.2.12.1 :ARCHTYPE n
Processors: STM8
Specifies the STM8 family via the numeral n, where n indicates the following:
161 = STM8S/STM8A
162 = STM8L101X
163 = STM8L15X
164 = STM8L16X
9.2.2.12.2 :COMMSMODE 0
Processors: STM8
Indicates that communications speed should be controlled automatically.
9.2.2.12.3 :FORCEPASS
Processors: STM8
If this command is present, read-out protection will be ignored, i.e. the target will be unsecured and
the programming process will continue.
If this command is missing, read-out protection will NOT be ignored. If the device is protected the
programming process will not proceed.
9.2.2.12.4 :RSTLOWPOSTSAP
Processors: All
Drives the RESET signal LOW before and after SAP operations.
9.2.3
Programming Commands
Programming Commands are the commands that will be executed during the programming
process. These are the main commands that will manipulate and verify data on your device. A list
of programming commands and their formats is included below.
See
Содержание Cyclone LC Series
Страница 1: ...Cyclone LC Programmers User Manual...
Страница 8: ...17 6 Debug Ports CYCLONE LC UNIV 149 17 7 International Shipping 149 17 8 Compliances Standards 149...
Страница 41: ...User Manual For Cyclone LC Programmers 41 Figure 5 2 Main Menu Structure...
Страница 134: ...User Manual For Cyclone LC Programmers 134 4 Click the Add New License button Figure 13 2 Add New License Button...