Basic operation
13
•
External output terminals
Name
Function
Switch means
•
Hold end signal
• An output that is turned on for 150 msec. (0.15 s)
after the end of the hold time.
• This signal does not output when the trouble output
is on.
• Normally open contact
Load at resistance load: 24 VDC, 30 mA or less.
-
•
Trouble output
• An output that is turned on when a major trouble
occurs.
• Input the “Trouble reset input” to reset.
• It is factory set to “normally open” at shipment.
Load at resistance load: 24 VDC, 30 mA or less.
JP1
(To select a contact type.)
•
Welding counter completion
output
• An output that is turned on when the counter
reaches the preset welding count.
• Input the “Welding counter reset input” to reset the
counter to zero.
• Normally open contact
Load at resistance load: 24 VDC, 30 mA or less.
-
•
Production counter completion
output
or
•
Step-up completion output or
Signal-up completion output
<When is set to “Production counter completion
output” mode>
the signal is turned on when the counter reaches
the preset number of products.
• Input the “Production counter reset input” to reset to
zero.
<When it is set to “Step-up completion output” mode>
the signal is turned on when “step-up” or “Signal-
up” (depending on the current incremental method
setting) is completed
• Input the “Step-up reset input” to reset the counter
to zero.
JP2
(To select a counter
completion output type.)
DIPswitch: DPSW1-10
(To select a current
incremental method.)
•
Pressure control output
• Connect the power amplifier when the proportional
control valve (optional) is applied.
DIP switch 2-1
(To use this function)
•
Welding current interlock output
• An output to interlock welding current with another
unit.
• An output that is turned on while welding current is
flowing (from the start of the upslope to the end of
the down-slope.)
• The signal does not output when the “Current off” is
selected.
• Normally open contact
Load at resistance load: 24 VDC, 30 mA or less.
-
•
SOL
I (
Solenoid valve 1
)
Connect the solenoid valve for pressing (100 VAC)
• As they are SSR output, 100 VAC is output even in
ready state.
-
•
SOL
II
(Solenoid valve 2)
-
•
24 VDC output
An auxiliary power for an external device.
Make sure to use it at 100 mA or less.
Do not use it to any device that generates noise.
Polarity: 44 (positive), 14 (negative)
-
•
100 VAC output
An auxiliary power for an external device.
Make sure to use it at 0.2 A or less.
Do not use it to any device that generates noise.
-
* As for “Switch means”, see section “Applied function: Selecting functions” for details.