37
English
Setting the security alert
[Security Alert]
[Device Control]
Set whether to control external control outputs.
OFF:
External control outputs are not controlled.
ON:
External control outputs are controlled.
Default setting: OFF
[TALK & PAGE Recording]
Communications ([TALK] and [PAGE]) in the lane in
which a security alert occurs are recorded on the SD
card.
OFF:
Communications are not recorded.
ON:
Communications are recorded.
Default setting: OFF
w
p
You can record communications for up to 5 minutes.
w
p
You can record up to 100 communications. When
more than 100 communications are recorded, the
oldest recorded file is recorded over.
w
p
The recordable time depends on the capacity of the
SD card. If the free space on the SD card is less
than 5 minutes, the oldest recorded file is deleted to
increase the free space, even if the number of records
is less than 100. Then recording continues as long as
there is free space.
w
p
The recorded communications are saved under the
filename “YYYYMMDD_hhmmss_“LANE”_nn(_D).
wav” on the SD card. (YYYYMMDD_hhmmss has the
following meaning; YYYY: Year, MM: Month, DD: Day,
hh: Hour, mm: Minute, and ss: second. “LANE” refers
to the lane in which the security alert occurred.)
During Daylight Saving time, “_D” will be added to the
filename when TALK & PAGE Recording is used.
w
p
For the destination to which to save the voice file,
refer to “Composition of folders on SD card” (p.40).
Note
When the [Alert 1 to 4] (alert input terminal) is
selected
[Message]
Touch the [Select] button to select the alert message to
be played back when a security alert occurs.
OFF:
Alert message is not played back.
Message number:
Alert message is played back.
Default setting: OFF
[Camera Monitoring]
Touch the [Select] button to select a Network Camera to
be displayed on the LCD display when a security alert
occurs.
OFF:
The image of the Network Camera is not
displayed on the LCD display.
Camera No.:
The image of the selected Network
Camera is displayed on the LCD display.
Default setting: OFF
[Device Control]
Set whether to control external control outputs.
OFF:
Not controlled
ON:
Controlled
Default setting: OFF
[Alert Input Delay Time]
Touch the [Edit] button and set the delay time after the
alert input terminal is controlled until the security alert
is turned on. When the alert input is canceled within the
delay time, the alert is not turned on.
You can set the delay time from 0 seconds to 29
minutes 59 seconds in increments of 1 second.
Default setting: 00:00 (00 minute 00 second)