39
Configure the settings relating to the camera action at an alarm occurrence
Click the [Alarm] tab on the "Alarm setup" page. (
☞
pages 4 and 5: How to display/operate the setup menu)
■
Camera motion on alarm
The settings relating to the camera action at an alarm occurrence can be configured in this section. Refer to pages
38, 41 and 42 for further information about the settings relating to the alarm, the alarm image and the alarm output
terminal.
[Command alarm]
Select "ON" or "OFF" to determine whether or not to use
the command alarm.
The command alarm is the function that provides notifi-
cation of a Panasonic protocol alarm from the other
cameras. When "ON" is selected, alarm actions will be
performed between multiple cameras.
Default:
OFF
[Originating port number]
Select a port number to be used to receive the com-
mand alarm.
Available port number:
1 - 65535
Default:
8181
[Terminal alarm 1]
Select an action to be taken when a terminal alarm 1 is
detected from the following.
OFF:
Does not take any action even when a terminal
alarm 1 is detected.
1-256:
When the registered preset position is selected,
the camera will move to the selected preset position
when a terminal alarm 1 is detected.
Auto track:
When a terminal alarm 1 is detected, the
camera will start the auto tracking.
When the home position is set, the camera will start
auto tracking after moving to the home position
once.
Patrol 1:
When a terminal alarm 1 is detected, the cam-
era will start the patrol 1 operation.*
Default:
OFF
[Terminal alarm 2]
Select an action to be taken when a terminal alarm 2 is
detected from the following.
OFF:
Does not take any action even when a terminal
alarm 2 is detected.
1-256:
When the registered preset position is selected,
the camera will move to the selected preset position
when a terminal alarm 2 is detected.
Auto track:
When a terminal alarm 2 is detected, the
camera will start the auto tracking.
When the home position is set, the camera will start
auto tracking after moving to the home position
once.
Patrol 2:
When a terminal alarm 2 is detected, the cam-
era will start the patrol 2 action.*
Default:
OFF
[Terminal alarm 3]
Select an action to be taken when a terminal alarm 3 is
detected from the following.
OFF:
Does not take any action even when a terminal
alarm 3 is detected.
1-256:
When the registered preset position is selected,
the camera will move to the selected preset position
when a terminal alarm 3 is detected.
Auto track:
When a terminal alarm 3 is detected, the
camera will start the auto tracking.
When the home position is set, the camera will start
auto tracking after moving to the home position
once.