Adjustment
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
96
●
Receiver indicator operation 1 when error occurs
<Conditions: Line synchronization, Test input function invalid, Interlock function invalid>
Example: Series connection error (“2” blinks yellow)
Receiver
Light blocked state
Light received state
(all beam channels)
Top end beam channel
Light blocked
Light received
Light blocked
Light received
Bottom end beam
Light blocked
Light blocked
Light received
Light received
Other beam channels
Light received /
Light blocked
Light blocked
Light blocked
Light blocked
Control output
(OSSD 1 / 2)
OFF
OFF
OFF
OFF
OFF
Upper application
indicator (Note 1)
Turns OFF
Turns OFF
Turns OFF
Turns OFF
Turns OFF
Lower application
indicator (Note 1)
Turns OFF
Turns OFF
Turns OFF
Turns OFF
Turns OFF
Stable light
reception indi-
cator (Note 2)
Turns OFF
Turns OFF
Turns OFF
Turns OFF
Turns OFF
Digital indicator
Yellow number
blinks or lights
Yellow number
blinks or lights
Yellow number
blinks or lights
Yellow number
blinks or lights
Yellow number
blinks or lights
Frequency
indicator
Turns OFF
Turns OFF
Turns OFF
Turns OFF
Turns OFF
Function setting
indicator (Note 3)
Turns OFF
Turns OFF
Turns OFF
Turns OFF
Turns OFF
Interlock
indicator
Turns OFF
Turns OFF
Turns OFF
Turns OFF
Turns OFF
OSSD indicator
Lights red
Lights red
Lights red
Lights red
Lights red
Notes: 1) The states of the upper application indicator and lower application indicator can also be checked from
the side of the device.
2) The stable light reception indicator (green) does not light in the lockout state.
3) The function setting indicator (yellow / orange) lights yellow when the blanking function or parallel con-
nection is used, and blinks orange when the communication module
SF4D-TM1
(option) is connected.
4) For details on yellow blinking or lit numbers in the digital indicator, refer to
.
After removing the cause of the error, you must turn the power OFF and then ON (the device
will not recover automatically).
Cause of error: Control output (OSSD) short, scattered light detected, sensor failure, etc.
Refer to
to remove the cause of the problem.
Содержание WUME-SF4D-4
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2017 2 MEMO ...
Страница 126: ...Functions Panasonic Industrial Devices SUNX Co Ltd 2017 126 MEMO ...
Страница 130: ...Maintenance Panasonic Industrial Devices SUNX Co Ltd 2017 130 MEMO ...
Страница 140: ...Troubleshooting Panasonic Industrial Devices SUNX Co Ltd 2017 140 MEMO ...
Страница 174: ... Panasonic Industrial Devices SUNX Co Ltd 2017 174 MEMO ...