Functions
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
110
<Timing chart>
ON
OFF
ON
OFF
ON
OFF
0.03 to under 3 sec. (Note)
ON
OFF
ON
OFF
ON
ON
OFF
OFF
0.08 sec. or less
0.14 sec. or less
0.16 sec. or less
0.1 sec. or less
Muting sensor
C
Control output
(OSSD 1 / 2)
Light received
Light blocked
Light received
state
Muting sensor
A
Muting sensor
B
Muting sensor
D
Muting state
Muting auxiliary
output
Note: Using the communication module
SF4D-TM1
(option), you can change the allowed response time within
the range 0.1 to 4 sec.
<Reference>
The communication module
SF4D-TM1
(option) and Configurator Light Curtain software can be
used to invalid the muting function on a particular beam axis, and to specify the order of input of
muting inputs A and B for enabling of the muting function.