39
Before operation, setup of this unit is required. Setup is per-
formed from WJ-SX650 Series Administrator Console installed
on a PC. (Some settings are available from SETUP MENU of
this unit.) The following is an example of setup procedure.
Notes:
• Setup may differ depending on system composition.
(Settings of Step 1 and 4 in the following procedure
must be performed.)
• For Step 2, 3, 5 and 6 in the following setup procedure,
the factory default can be maintained.
Example: camera x 150, recorder x 10, monitor x 32, and
system controller x 2 (Terminal mode)
1. Perform the recorder settings.
Recorder Out:
Matrix Input
Input Board No.:
5 (When video input signals are sup-
plied from recorders to CAM 160 to 151)
Recorder 1 to 10:
ON
Recorder 11 to 16:
OFF
Note:
Check if recorders are properly connected to the
DATA port and CAM (CAMERA IN connectors) currently
displayed.
<To perform settings in WJ-SX650 Series Administrator
Console>
"System" – "Recorder"
<To perform settings in SETUP MENU>
RECORDER (Refer to p. 51.)
2. Perform the DATA port settings. (In this example, main-
tain the factory default.)
DATA 1, 2, 5 and 6 ports:
TMNL
DATA 3, 4, 7 and 8 ports:
HDR
Note:
Change these parameters when using PS·Data
system controllers, etc.
<To perform settings in WJ-SX650 Series Administrator
Console>
"System" – "DATA Port"
<To perform settings in SETUP MENU>
DATA PORT (Refer to p. 53.)
3. Perform the LCN (Logical Camera Number) settings.
CAM001 to 160:
If you change LCN settings, select
desired parameters.
CAM161 to 256:
Delete the LCN parameters.
Notes:
• Set LCN parameters for CAM151 to 160 surely, even
though these channels accept video input signals from
recorders. Without LCN settings, recorder selection is
unavailable.
• By deleting the LCN parameters of unused camera
input channels, operators can select only existing cam-
era numbers.
<To perform settings in WJ-SX650 Series Administrator
Console>
"System" – "Logical Camera Number"
<To perform settings in SETUP MENU>
Not available
4. Perform the camera settings.
CAM001 to 150:
Select desired parameters for these
cameras. (To use cameras of other manufacturers,
set VD2 and DATA to OFF.) For Cable (cable com-
pensation), select the parameter suited to the cable
length.
CAM151 to 160:
Set VD2 and DATA to OFF. (Video input
signals are supplied from recorders to these channels.)
<To perform settings in WJ-SX650 Series Administrator
Console>
"System" – "VD2/DATA/Cable Comp."
Setup Procedure
Содержание WJSX650 - SWITCHER
Страница 99: ...99 ...