Check item and remedy
Reference
Problem
Auto tracking ended before
the end time of camera event
setting.
Alarm event does not occur.
The image of camera associ-
ated with the alarm event was
not recorded.
The status before the alarm
occurrence is not recovered,
even though the alarm event
is reset.
Alarm modes of connected
devices are not reset even
after the unit is powered off.
Cannot open SETUP MENU
of the unit.
• Check if another camera event is not set for the camera.
• Check if the alarm input signal setting is ON in ALARM of
SETUP MENU.
• Check if the alarm event has been set.
• Check the active period setting of alarm schedule.
72
50
67
68
• Check if the alarm is not suspended and SETUP MENU is
not open on the associated monitor.
• Check the connection and settings between the recorder and
the unit.
49, 70
30
• Recording follows the recorder settings. Check the command
alarm setting and event recording setting of recorder.
• If an operator has activated a group sequence before the
alarm occurrence, and another operator reset the alarm or
performed operations on the monitor associated with the
group sequence, the status before the alarm occurrence is
not recovered.
• When you power off the unit, the alarm mode activated for
the unit is reset, but the alarm modes for the connected
devices are not reset. Power on the unit again, and perform
the Alarm All Reset operation.
• You cannot open SETUP MENU when another operator is
opening it.
• SETUP MENU cannot be displayed on a monitor associated
with an active alarm.
–