69
Alarm Control
■
Alarm Acknowledgement (ACK)
By acknowledging an alarm occurrence on an associated
monitor, you can control alarm pictures.
●
WV-CU950/650
While a monitor in the alarm mode status is selected, press
the ACK button. (During the alarm mode status, "Alarm"
sign is blinking on the LCD.)
The alarm event will be acknowledged. ("Alarm" sign will
change to steady light.)
●
WV-CU360C/CJ
While a monitor in the alarm mode status is selected, press
the ACK button. (During the alarm mode status, the alarm
number is blinking on the LED display.
The alarm will be acknowledged. (The alarm number will
change to steady light.)
In the ACK status, the following operations are available.
■
Camera Control
You can control panning/tilting of cameras, or move cam-
eras to preset positions, etc.
■
Alarm Picture Change
When two or more alarms are occurring, you can change
alarm pictures displayed on the monitor in order or reverse
order.
●
WV-CU950/650
To change alarm pictures on the monitor, press the + or –
button. The alarm pictures will be displayed in order or
reverse order.
●
WV-CU360C/CJ
To change alarm pictures on the monitor, press the NEXT
or PREV button. The alarm pictures will be displayed in
order or reverse order.
■
Alarm Individual Reset
You can reset each acknowledged alarm separately, and
return to the status before alarm occurrence. While two or
more alarms are occurring, the system will remain in the
alarm mode even after an alarm reset.
To reset an acknowledged alarm, press the ACK button.
The alarm will be reset.
Notes:
• An alarm whose Display Mode setting is OFF will not be
the ACK status. The alarm will be reset by every press-
ing the ACK button.
• If AUTO RESET has been set to ON, alarms will be reset
automatically after the specified time. AUTO RESET set-
ting is performed in "Alarm" – "Alarm Mode" of WJ-
SX650 Series Administrator Console or the ALARM
menu of SETUP MENU. Refer to p. 50 ALARM of SETUP
MENU.
■
Alarm Monitor Reset
You can reset all the alarms occurred to the selected moni-
tor.
While the selected monitor is in the alarm mode status,
press the ALM RESET*
1
(or RESET*
2
) button. All the alarms
occurred to the monitor will be reset, and the monitor dis-
play will return to the status before the alarm occurrence.
*
1
WV-CU950/650
*
2
WV-CU360C/CJ
Note:
Alarm monitor reset is also available by supplying
Alarm Recover Input signals to the unit. (Refer to p. 37.)
■
Alarm All Reset
You can reset all the alarms occurred to the system.
Press the ALM ALL RESET*
1
(or ALL RESET*
2
) button while
holding down the SHIFT button. All the alarms occurred to
the system will be reset.
Содержание WJSX650 - SWITCHER
Страница 99: ...99 ...