39
■
ALARM NOTICE
The WJ-NT104 can notify the user of an alarm event.
The notice is sent either by Panasonic original protocol,
e-mail (SMTP client) or a combination of both.
●
E-Mail Notice
Mail is sent to the mail server using SMTP (Simple Mail
Transfer Protocol).
16 mail addresses can be specified.
• Mail contents include the URL to access the alarm
image, date and time (hours, minutes, seconds) of
the alarm, camera channel, and connection port
ID.
• If mail is not sent to the mail server before the set
timeout, the mail is automatically deleted.
• In case of continuous recording [after/before], mail
contents are as follows:
[Explanation]
NT104:
Host name set by network setup (8 characters
maximum). Default setting is WJ-NT104.
Date and time of alarm activation:
Based on the time of the internal clock of the
WJ-NT104.
Generating port:
Port number of the alarm input/output terminal
where an alarm is generated
Link to alarm image:
Alarm image URL. In continuous recording
mode, the URL of the first image. In the follow-
ing cases, accessing the URL may not display
the alarm image.
q
Alarm image is overwritten.
(For the number of alarm images recorded see
page 38.)
w
Alarm log is overwritten.
(Up to 100 alarm logs can be recorded.)
e
NT104 is restarted due to a change in settings.
r
Power is switched back on or the reset button
is pressed.
Number of frames recorded:
Number of alarm images to be recorded.
None in case Single Frame Recording
mode.
[Example]
If the PC on the alarm receiving end does not respond
after a specified number of connection retries because it
is not powered up or for some other reason, the WJ-
NT104 sends the alarm notice to another PC registered
as an alarm notice recipient.
Note
●
Panasonic Original Protocol Notice
(option)
This is a special protocol based on the TCP/IP protocol
used to notify the users of an alarm.
If an alarm is activated, an alarm notice is sent to the
PC IP addresses set for the WJ-NT104 as alarm notice
recipients.
• To receive alarms, you need to install the special
alarm receiving software for the WJ-NT104 (option)
on your PC. Your PC must be kept powered up
and connected to the WJ-NT104 via a LAN.
• Up to 16 alarm notice destinations can be speci-
fied for the WJ-NT104.
■
Alarm Image Readout
Recorded alarm images can be read out by accessing
the alarm list (almindex.html) of the WJ-NT104.
!!! ALARM NOTICE !!!
Source
: 133. 185. 10. 47 (NT104)
Port
: PI0 5ch
Date
: Jul/04/99
Link
: http://133. 185. 10. 47/ALM0001_00.JPG
<NUMBER OF FRAMES RECORDED>
Total
: 14
Before
: 4
After
: 10