46
■
SERIAL PORT SETUP
On the
ADMINISTRATOR SETUP PAGE
, click the
SERIAL PORT
button to display the
SERIAL PORT SETUP
window.
Specify whether to use the RS-232C or RS-485 interface, and set the communication parameters.
q
TYPE (RS-232C)
Set up the RS-232C port usage. Select NONE,
MODEM/TA, WJ-SX550A, WJ-FS616, WJ-DR200 or
Serial Through.
The factory default setting is
NONE
.
w
BAUD RATE (RS-232C)
Set the baud rate for RS-232C to 300, 1200, 2400,
4800, 9600, 14400, 19200, 38400, 57600, or 115200
bps can be selected.
The factory default setting is
4800 bps
.
It is recommended that 38400 bps be selected for a 56
kbps modem, and 57600 bps when for a TA.
e
DATA BIT (RS-232C)
Set the data bits for RS-232C.
The factory default setting is
8 bits
.
r
STOP BIT (RS-232C)
Set the stop bit for RS-232C.
The factory default setting is
1 bit
.
t
PARITY (RS-232C)
Set the parity bit for RS-232C.
The factory default setting is
NONE
.
y
USE FLOW CONTROL (RS-232C)
Set flow control for RS-232C.
The factory default setting is
NONE
.
u
TYPE (RS-485)
Set up the RS-485 port usage. Select NONE or CAM-
ERA + WJ-SX550A.
The factory default setting is
NONE
.
i
BAUD RATE (RS-485)
Set the baud rate for RS-485 to 1200, 2400, 4800,
9600, 19200, or 38400 bps can be selected.
The factory default setting is
4800 bps
.
o
DATA BIT (RS-485)
Set the data bits for RS-485.
The factory default setting is
8 bits
.
!0
STOP BIT (RS-485)
Set the stop bit for RS-485.
The factory default setting is
1 bit
.
!1
PARITY(RS-485)
Set the parity bit for RS-485.
The factory default setting is
NONE
.
!2
X ON/X OFF (RS-485)
Set flow control for RS-485 (X ON/X OFF).
The factory default setting is
OFF
.
!3
DUPLEX MODE
Set the communication mode for RS-485.
The factory default setting is
FULL DUPLEX
.