Press the button by piercing the
section (section covered with a seal)
using a flathead screwdriver or similar
A
Abnormal
case "off"
switch
The abnormal case "off" switch is
under the setting cover.
As a primary measure for the abnormal condition
of the base unit or the call sub-base unit with
monitor, such as the alarm sound does not stop
with the STOP ALARM button, press the abnormal
case "off" switch, and then contact the
administrating company or the company that
installed the system. (All the function are stopped.)
Groove
■
Removing the setting cover
Open by hooking the finger to
the groove
A
221
220
Troubleshooting
Expire Date of the Gas Alarm
●
Voltage contact 2-stage output type
(Normal condition: DC6 V, During gas leak alarm: DC12 V, During equipment or wiring abnormality: 0 V)
●
Voltage contact 3-stage output type (with imperfect combustion (CO) alarm)
●
An expiration date is defined to maintain the function of the gas alarm connected to the base unit.
●
Make sure to replace with a new gas alarm before the expiration date.
Always perform the operation check after replacement.
●
The gas alarm must conform to the city gas alarm voltage output uniform standard by the Gas Alarm
Industries Association of Japan.
Normal condition: DC6 V, During gas leak alarm: DC12 V,
During incomplete combustion: DC18 V, During equipment or wiring abnormality: 0 V
Stop the alarm sound with the STOP ALARM button when the alarm of the base unit or the call sub-base
unit with monitor does not stop.
Perform following measure if the alarm still does not stop.
How to install
How to remove
2
1
Remove the cover fixing screw (1 location)
Disconnect connectors (2 locations)
There is a danger of exposed power supply when the cover is removed. Do not remove the cover except
when there is an abnormality.
1
Insert the connectors (2 locations) into
the connector ports on the base
3
Fix with the cover fixing screw (1 location)
2
Hook the tab at the top of the cover to
the base
●
There are cases that the function may not stop even the abnormal case "off" switch is pressed.
In such case, remove the base unit cover and disconnect the connectors connected to the base.
Only for the base unit for the condominium building (VGDT item number)
Base
Connector
Connector
port
Connector
Cover fixing screw
Setting cover
INTRODUCTION
USUAL USAGE
SETTING ACCORDING TO
YOUR PREFERENCES
OPERATIONS AND MEASURES
WHEN ALARM GOES OFF
SECURITY ALARM SETTING
AND DISARMING
RECORD
MANAGEMENT
OTHER
解錠
通話
UNLOCK
TALK
復旧/警報音停止
非常
RESET/
STOP ALARM
EMERG.
FIRE CONFIRM
MENU
OFF
火災
確認
終了
メニュー
電源
POWER
■設定時、
この保護
シートを
はずして
設定して
ください
。
■設定完了後、
保護シー
トを
もとに
戻してくだ
さい。
施工店様
へ
Note
Note
Cover
●
For VGDT item number base unit
●
The illustration indicates
the VGDT item number
(AC100 V type).