42
5. Route the remote controller cable (2) inside the lower
case in accordance with the intended feeding-out
direction. (Refer to the illustration at below)
6. Insert firmly the connector of remote controller cable (2)
to connector (CON1) in the upper case circuit board.
(Refer to the illustration at below)
7. Secure the remote controller upper case to the lower
case with the tabs provided.
11.4.3.3. Connecting The Remote Controller’s Cable To Mono bloc Unit
1. Remove the cabinet front plate.
2. Connect the remote controller’s cable with the provided
connector as shown in below illustration. (Refer wiring
diagram for detail.)
3. Guide the remote controller cable through the clamper
and Bushing .
(Refer illustration “How to connect Remote Controller to
Provided Connector” for detail.)
4. Reinstall the cabinet front plate after connection
complete.
11.4.3.4. Disposal of Mono bloc Unit Drain Water
• When a Drain elbow is used, please ensure to follow below:
- The unit should be placed on a stand which is taller than 50mm.
- Cover the 8 holes (ø20mm) with Rubber cap (refer to illustration below)
• If the unit is used in an area where temperature falls below 0°C for 2 or 3 consecutive days, it is recommended not to use the
Drain elbow and Rubber cap , for the drain water freezes and the fan will not rotate.
Be sure to turn off the main power before installing and connecting the
remote controller. Otherwise, it will cause the electrical shock.
Содержание WH-MXF09D3E5
Страница 10: ...10 4 Location of Controls and Components 4 1 Monobloc Unit ...
Страница 11: ...11 4 1 1 Main Components ...
Страница 13: ...13 ...
Страница 15: ...15 4 1 4 Basic Operation 4 1 5 Advance Operation ...
Страница 16: ...16 4 1 6 Weekly Timer Setting ...
Страница 17: ...17 5 Dimensions 5 1 Monobloc Unit ...
Страница 18: ...18 6 Refrigeration And Water Cycle Diagram ...
Страница 19: ...19 ...
Страница 20: ...20 7 Block Diagram 7 1 WH MXF09D3E5 ...
Страница 21: ...21 7 2 WH MXF12D6E5 ...
Страница 22: ...22 8 Wiring Connection Diagram 8 1 WH MXF09D3E5 ...
Страница 23: ...23 ...
Страница 24: ...24 8 2 WH MXF12D6E5 ...
Страница 25: ...25 ...
Страница 26: ...26 9 Electronic Circuit Diagram 9 1 WH MXF09D3E5 ...
Страница 27: ...27 ...
Страница 28: ...28 9 2 WH MXF12D6E5 ...
Страница 29: ...29 ...
Страница 30: ...30 10 Printed Circuit Board 10 1 Water System 10 1 1 Main Printed Circuit Board ...
Страница 31: ...31 10 1 2 Solar Printed Circuit Board Optional ...
Страница 32: ...32 10 2 Refrigerant System 10 2 1 Main Printed Circuit Board ...
Страница 33: ...33 10 2 1 1 Capacitor Printed Circuit Board 10 2 1 2 Noise Filter Printed Circuit Board ...
Страница 34: ...34 11 Installation Instruction Monobloc Unit Dimension Diagram ...
Страница 55: ...55 ...
Страница 56: ...56 ...
Страница 103: ...103 17 3 To Remove The Cabinet Rear Plate 17 4 To Remove Pressure Gauge 17 5 To Remove RCCB ...
Страница 109: ...109 19 Exploded View and Replacement Parts List 19 1 Refrigerant System ...
Страница 110: ...110 ...
Страница 114: ...114 19 2 Water System ...