background image

www

.eggeassociats.net

To find out how Panasonic cares for you, 

log on to: www.aircon.panasonic.co.uk

Do not add or replace refrigerant other than the specified 
type. Manufacturer is not responsible for the damage and 
deterioration in safety due to usage of the other refrigerant.

Due to the ongoing inno

vation of our pr

oducts, the specif

ications of this catalogue ar

e v

alid barring typogr

aphic err

or

s, and ma

y be subject to minor modif

ications b

y the manufactur

er

without prior w

arning in or

der to impr

ov

e the pr

oduct. The total or partial r

epr

oduction of this catalogue is pr

ohibited without the e

xpr

ess authorisation of P

anasonic UK Ltd.

Contact Details:
Telephone: 01344 853182
[email protected]

Address: Panasonic Air Conditioning
Panasonic House
Willoughby Road
Bracknell
Berkshire
RG12 8FP

UK_MANUAL_B.indd   12

29/07/15   12:18

Содержание WH-ADC Series

Страница 1: ... GUIDE FOR BI BLOC MONOBLOC ALL IN ONE WH ADC___G__ WH SDC___F__ WH SXC___F__ WH SHF___F__ WH MDC___F__ WH MHF___F__ AQUAREA USER GUIDE FOR BI BLOC MONOBLOC AND ALL IN ONE SYSTEMS UK_MANUAL_B indd 1 29 07 15 12 17 ...

Страница 2: ...ners or scouring powder Service to units should be carried out by Qualified Personnel only Control Panel Do not let the control panel get wet Do not press the buttons on the control panel with hard pointed objects Otherwise it may cause damage 1 Safety precautions 2 2 Overview of ASHP system supplied 3 3 Control panel function 5 4 Operating Instructions of System 5 5 Troubleshooting 9 6 Error Faul...

Страница 3: ...e also connected to house management system using KNX Modbus or Zig Bee interfaces 2 Aquarea Air High efficient radiators for heating and cooling Optional High efficient radiators working with water at 35 C No need for two kits if both floor heating and radiators are required As the product is efficient it opens the possibility to also provide cooling while still meeting construction requirements ...

Страница 4: ...en the fan is turning to start the process of changing this low temperature to a high temperature using a compression cycle once the compression cycle is carried out the heat is transferred to the heating or hot water depending on requirements Monobloc Panasonic supply 2 types of heat pumps firstly a Monobloc system in this system the hot water produced to feed the heating and hot water is produce...

Страница 5: ...e 3 Water inlet temperature 4 Water tank temperature Press the CANCEL button or wait 30 seconds to quit Status mode Service button Engineer use only Button for enabling the additional electric heater for the heat pump The additional electric heater can only be used if this button is pushed Note If this button is not pressed the additional electric heater for the heat pump is only used for Defrosti...

Страница 6: ...N or OFF To turn ON or OFF the heat pump cooling operation To enjoy quiet environment This operation reduces heat pump unit noise In this condition it may cause decrease in heating capacity To enable the backup heater The backup heater will only operate when the setting conditions are fulfilled To disabled the Heater operation manually press the respective button again REMOTE CONTROL PREPARATION S...

Страница 7: ...t operation to be carried out If HEAT or HEAT TANK is selected you are able to change the shift temperature with the UP or DOWN bottom Press the SET button to confirm Program 1 The selected day is identified with the symbol After 2 seconds the display will move to the next program 8 Repeat the steps 4 to 7 starting with the OFF ON button to set additional commands 2 to 6 if required 9 If no button...

Страница 8: ...value measured by precise equipment In normal operation the and buttons are not in use Holiday mode By setting the day s in holiday mode it promotes energy saving while you are on holiday and enables the system to resume at the preset temperature after your holiday Ensure that the system is OFF before setting The system will resume operation automatically at 00 00 am after the holiday The day the ...

Страница 9: ...ater in the cylinder is above 60 ºC only if controlled by A2W heat pump The operation LED blinks and error code appear on remote control display Turn the unit off and reveal the error code to authorised dealer Timer operation cancel when error code occur Force Heater Mode Button In case of a failure of the heat pump system but still power to the unit the electric heaters can be activated to provid...

Страница 10: ...uoting fault code H12 Unsuitable output between the indoor and outdoor unit Contact your local Panasonic installer quoting fault code H15 Compressor temperature sensor Contact your local Panasonic installer quoting fault code H20 Water pump abnormal Reset once if reoccurring contact your local Panasonic installer quoting fault code H23 Liquid temperature sensor Contact your local Panasonic install...

Страница 11: ...onic installer for more details 8 Technical Support Contact details Please call your installer as the first point of call indicating the fault or fault code otherwise please call Panasonic Technical Support 01344 853 393 for assistance Your warranty card details will be required 9 Recycling of Units After the end of the product s service life it must be disposed of appropriately The respective env...

Страница 12: ...products the specifications of this catalogue are valid barring typographic errors and may be subject to minor modifications by the manufacturer without prior warning in order to improve the product The total or partial reproduction of this catalogue is prohibited without the express authorisation of Panasonic UK Ltd Contact Details Telephone 01344 853182 uk aircon eu panasonic com Address Panason...

Отзывы: