19
Troubleshooting
When a problem occurs, please refer to this page. The "Reference Manual" also contains detailed information. If a problem
appears to be related to a software application, read the software related manual. If you still cannot troubleshoot the problem,
contact Panasonic Technical Support.
Starting Up
The red battery indicator
lights.
Repeated beeping sound
while the computer is in use.
The red indicator blinks
After the AC adapter is con-
nected, the orange indicator
blinks five times
The battery level is low. Save your data and power off your computer.
After connecting the AC adapter or replacing the battery pack with a fully charged one, turn
your computer on.
The battery pack or recharging function may be defective. Quickly remove the battery
pack and disconnect the AC adapter, then connect them again.
If the problem persists, contact Panasonic Technical Support.
Unable to charge because of an improper temperature range. (
page 6)
Battery Indicator
The power indicator or bat-
tery indicator is not lit
or
is displayed
[POST Startup Error(s)] is
displayed
Windows startup, or an op-
eration is extremely slow
The date and time are
incorrect
Others
Check the cable connection for the AC adapter.
Check to see if a fully charged battery is properly installed.
Remove the battery pack and disconnect the AC adapter, then connect them again.
Input your password. If you have forgotten it, contact Panasonic Technical Support.
page 17
Press
F9
in the Setup Utility (
"Setup Utility"). This will restore the Setup
Utility's settings to their default values (except the password settings). Then, the Setup Utility
must be run once again for you to input the appropriate operating environment settings. (The
processing speed depends on the application software used, so this operation may not cause the
processing speed to increase.)
You can set the date and time through [Date/Time] in [Start] - [Settings] - [Control Panel].
When the computer is connected to a Local Area Network (LAN), confirm the date and
time of the server.
If you continue to experience problems, the internal battery maintaining the clock may
need to be replaced. Contact Panasonic Technical Support.
Press
F9
in the Setup Utility (
"Setup Utility"). This will restore the Setup
Utility's settings to their default values (except the password settings).
Try removing all peripheral devices.
In the MS-DOS mode, run SCANDISK to check the hard disk.
At start-up, press
F8
(
Ctrl
) to operate the computer in the Safe mode.
Windows 98
Press
Ctrl
+
Alt
+
Del
to reboot the computer.
After cutting the power by pressing the sleep switch for more than four seconds, slide the
power switch to power on and open the application again.
If the program no longer works normally, go to [Start] - [Settings] - [Control Panel] -
[Add/Remove Programs] to delete the program. Then try installing the program once
again.
Computer hangs
Application Software
Unable to shut down Win-
dows
Shutting down
Do not shut down Windows during music playback.
If a USB device is connected, try removing it.
Windows 95
Dealing With Problems
(Summary)
Содержание Toughbook CF-47 Series
Страница 30: ...30 Appendix...
Страница 31: ...31 Appendix...