Problem
Check point
W
ater leakage
Faucet and connection parts
of bypass selector, water
supply hose, and outlet pipe
See P. EN20
~
EN21.
Bypass selector
(location other than the
water outlet selected with
the bypass selector)
Though the bypass selector is
adjusted to
, water drips
from the source water opening.
The cause seems to be calcium, etc. depositing inside the bypass
selector.
→ Dissolve approx. 50 of citric acid in 1 liter of water. Remove the
bypass selector (P. EN28) and hose, soak them in the citric acid
water for approx. 12 hours, and wash them with water.
(Buy citric acid at a pharmacy.)
Bottom of the unit
Has the cartridge been installed securely? (P. EN30)
Depending on the temperature and
humidity conditions, water formed from
condensation may collect inside the unit.
(This is not a malfunction)
Condensation
water outlet
Bottom of the unit
Main spout
Water drips or trickles
out of the main spout
even when the water is cut off
This is not a malfunction. (The water fl ows out is the water
residing in the piping.)
No water or very little
is discharged from
the Alkaline Ionizer
Is the faucet fully open?
Is the fi lter of the bypass selector clogged?
→ Perform maintenance. (P. EN28)
Has the water supply been cut off ? (P. EN33)
Is the water supply hose bent or fl attened?
If the problem is still not solved after all of the above are checked,
the cartridge may be clogged. Replace the cartridge. (P. EN30)
is
displayed
Not much water comes
out of the Alkaline Ionizer
after the cartridge has
been replaced
Did you run water for approx. 3 to 4 minutes after replacement?
(P. EN30)
(It is necessary to remove the air inside the cartridge)
Much water comes out
The water amount from the main spout varies depending on the
kind of water and/or selection of the water quality even though the
amount of source water stays constant.
Maximum fl ow varies depending on the kind of water and/or
selection of the water quality.
has become
more likely to be displayed
The water comes out from
the main spout is warm
At an early stage of running of water, the water warmed by the
room temperature or heat inside the Alkaline Ionizer while water
fl ow is stopped may come out.
(This is not a malfunction. Allow the water to fl owing before uses.)