Simple Power On Sequence 1
Power SW on / Remote on
< Display start >
( Plug in )
46
Power Off
Standby
Power On
16V / 64V(*) output / PFC circuit start working
TV_SUB_ON signal
STB5V output
Stop 16V / 64V(*)
PNL12V output
PANEL_VCC_ON signal
Power LED Green
Stop 16V / 64V(*)
Power LED off
TV_SUB_OFF
TV_SUB_OFF
AC Plug in
STB5V (form P to A)
16V (from P to A)
PNL12V (from A to Panel(T-CON) )
SUB_ON (from A to P)
Power LED
Panel_Vcc_ON (from A to Panel(TCON))
VLED (from P to Panel(Backlight) )
BL_ON/EVDD_ON (from A to P)
(Standby)
Power on
(Standby)
Power on
Power on
Standby / Power on
5V
16V
12V
ex.64V(*)
VLED,
ex. 110V
64V(*) up to VLED
BL_ON_ON signal
Power LED Red
(*) The DC level is different by the LCD panel.
TH- ##JX800*, 900W (Android TV)