background image

Page 6 of  13

Model
Name

Model
No.

Switch-M8eGi

PN28080i-ID

Product Specification

401-28080i-ID-SP01

Panasonic Life Solutions Networks Co., Ltd.

Date revised

Date issued

May. 26, 2020

Control parameters can be set by the following procedures:
(1) Configuration from an asynchronous terminal connected to the console port.
(2) Configuration from a remote terminal connected via TELNET and SSH
(3) It can be set from a remote terminal according to the Web screen.

Management protocol

:SNMP v1/v2c/v3 (RFC1157,RFC1901,

RFC1908)

TELNET             (RFC854)

SSH v2

(RFC4251,RFC4252,

RFC4253,RFC4254)

SNTP v3              (RFC1769)

Data transfer protocol

:TFTP  

(RFC783,RFC1350)

It is possible to check the control and operation of the Switching Hub by ZEQUO 
assist Plus. 
Switching Hub can be controlled by the following procedures:

(1) Control from an asynchronous terminal connected to the console port.
(2) Control from a remote terminal using SSH/TELNET and TCP/IP network      

connection

(3) Control using SNMP Manager

The switching Hub operation status can be checked using the following functions.

(1) Function to display the CPU
(2) SFP module status checking function (DDM: Digital Diagnostic Monitoring)

6-3. Rebooting

6-2. Switching Hub  Control

6-4. Supported Agent

The system can be reset from the software in the following three modes:

(1) Warm start
(2) Reset to factory default
(3) Reset items other than the IP address to factory default

The reboot timer function can also be used in each mode. 

6-1. Configuration

6. Software Specifications

RFC1213-MIB(MIBⅡ)

(RFC 1213) (*1)

BRIDGE-MIB

(RFC 4188) (*2)

SNMPv2-MIB

(RFC 1907)

RMON-MIB

(RFC 2819) Only etherStatsTable

SNMP-FRAMEWORK-MIB

(RFC 2571)

SNMP-MPD-MIB

(RFC 2572)

SNMP-NOTIFICATION-MIB

(RFC 2573N)

SNMP-TARGET-MIB

(RFC 2573T)

SNMP-USER-BASED-SM-MIB

(RFC 2574)

SNMP-VIEW-BASED-ACM-MIB

(RFC 2575)

SNMP-COMMUNITY-MIB

(RFC 2576)

IP-MIB

(RFC 4293) (*3)

IF-MIB

(RFC 2233) Excluding IfMIB

IEEE8021-PAE-MIB

(IEEE802.1X) Excluding dot1xPaeSupplicant

*1 Excluding following item 

At , ipRouteTable, icmp, egp

*2 Excluding following item

dot1dStp, dot1dSr, dot1dStatic

*3 Excluding following item

ipDefaultRouterTable, ipv6RouterAdvertTable

6-5. Supported MIB

6-6. System log

Maximum number to be kept: 256
System log transfer (IPv4/IPv6)

Содержание Switch-M8eGi Series

Страница 1: ...a loop detection history function which notifies when a loop occurs with the corresponding LED and enables a network administrator to identify the looped port after the loop is removed 6 Fanless desi...

Страница 2: ...e plate label Black 04 3 1 Power supply AC100 240V 50 60Hz 0 5A with a built in power supply 3 2 Power consumption 3 3 Operating environment Temperature 0 60 Humidity 20 80 RH no condensation 3 4 Stor...

Страница 3: ...EEE802 3az LPI When there is no data transmission at link up the energy saving state automatically starts so that power consumption can be reduced on each port Factory default Disable SFP extension sl...

Страница 4: ...lay for the connection with a connected terminal Status mode Display for the 1000 Mbps transmission rate GIGA mode Display for the 100Mbps or 10 Mbps transmission rate Speed mode Display for the full...

Страница 5: ...nk Off Green Light Off Port LED Left Right Port LED Left Port LED Right 5 Hardware Specifications Link is established Transmitting and receiving data No device connected Link is established at 1000Mbp...

Страница 6: ...on status can be checked using the following functions 1 Function to display the CPU 2 SFP module status checking function DDM Digital Diagnostic Monitoring 6 3 Rebooting 6 2 Switching Hub Control 6 4...

Страница 7: ...the power is turned OFF Loop shutoff time 60 to 86 400 sec Factory default setting 60 sec The set time Port LED lights up orange and the port shuts off Loop history retention time 3 days The LOOP HIS...

Страница 8: ...n EAP MD5 TLS PEAP Authentication method Web based authentication Mac based authentication using IEEE 802 1X Web based authentication Dynamic VLAN function using IEEE 802 1X Guest VLAN using IEEE 802...

Страница 9: ...mount brackets to the Switching Hub 8 8 Screw for fixing the connection bracket 8 9 Power cord CEE7 7 1 The attached power cord is dedicated for AC 100 240 V use 10 2 Accessories 8 2 2 Time setting SN...

Страница 10: ...125 m Multi Mode Fiber 62 5 125 m Multi Mode Fiber Maximum transmission distance 550 m at 50 125 m 220 m at 62 5 125 m 11 1 1000BASE SX SFP Module i Model No PN54022 ID 11 2 1000BASE LX SFP Module i...

Страница 11: ...orrosive and combustible gases Deviation could lead to fire electrical shock and or equipment failure 8 Do not place this Switching Hub under direct sunlight and or high temperature Deviation could le...

Страница 12: ...use the optical signal to not be transmitted normally and cause misoperations and malfunctions If they are contaminated make sure to clean them off then connect them to the optical fiber ports 9 This...

Страница 13: ...r use this Switching Hub in the environment in accordance with the specification High humidity Possible spilled liquid water Dusty Possible static charge such as carpet Under direct sunlight Possible...

Отзывы: