background image

Page 12 of  13

Model
Name

Model
No.

Switch-M8eGi

PN28080i-ID

Product Specification

401-28080i-ID-SP01

Panasonic Life Solutions Networks Co., Ltd.

Date revised

Date issued

May. 26, 2020

Denotes that “Minor injuries might be sustained, or property damage might occur”.
The manufacturer assumes no responsibility for any problems occurring when the following conditions are not satisfied.
Observe the following items when using the product.

(1) Use the bundled power cord (AC 100 – 240 V specifications).

Deviation could lead to electric shock, malfunction, and/or equipment failure.

(2) Unplug the power cord in case of equipment failure.

Deviation, such as keeping connected for a long time, could lead to fire.

(3) Be sure to connect the ground cable.

Otherwise this might cause electrical shocks, misoperations and malfunctions.
Connect the Switching Hub via the supplied power cord to the outlet which is connected to the ground.
If the outlet is not connected to a ground, connect the ground cable (AWG18:green/yellow) to the ground terminal screw.

(4) Connect the power cord firmly to the power port.

Deviation could lead to electric fire, shock, and/or malfunction.

(5) If the STATUS (Status) LED blinks orange, unplug the power cord since this is a malfunction.

Deviation, such as keeping connected for a long time, could lead to fire.

(6) Handle the Switching Hub carefully so that fingers or hands may not be damaged by twisted pair port, SFP extension slot, 

console port, or power cord hook block.

(7) Up to two Switching Hubs can be connected by using the connection brackets and connection bracket screws. 

Attach the connection brackets to the connection bracket screw holes on the front and back panels to securely fix the 
Switching Hubs before installation.

If the Switching Hubs are not fixed securely, they may fall, leading to injury and/or equipment failure.

(8) Check whether the optical fiber cable connectors are contaminated with dust, etc.

This might cause the optical signal to not be transmitted normally, and cause misoperations and malfunctions.
If they are contaminated, make sure to clean them off, then connect them to the optical fiber ports.

(9) This Switching Hub is to be periodically serviced in order to maintain its performance.

Please choose a product administrator, and have them be sure to implement periodic maintenance. When doing maintenance, 
check the inspection chart that is posted on our website which has the requisite items listed on it.

(10) When using this Switching Hub to design systems, use it after applying appropriate measures such as setting up redundant 

configurations.
Communications failures might be generated due to causes such as malfunctions or misoperations while the Switching Hub is 
being used.

(11) When using this Switching Hub for applications which require extremely high reliability, be careful to expend all possible means 

to ensure safety and reliability.
This Switching Hub was not designed nor manufactured with the intention that it be used for applications (in use with railways, 
aviation, and medical care, etc. whereas the influence rate due to communications failures is extremely high in regard to 
systems that directly affect systems and human lives) which require extremely high reliability.

(12) Be aware of glitches which are caused in the usage environments such as age-related degradation, etc.

This may vary depending upon conditions such as utilisation rates and usage environments, but performance might decrease
due to the age-related degradation, etc. of components. It is recommended that this Switching Hub be replaced about 
five years after it has been installed.

(13) Be careful in regards to environmental restrictions whereby the Switching Hub can be used.

Please isolate the business power lines and communications lines. Isolate distribution lines and other distribution lines,
and low current power lines, optical fiber cables, metallic water conduits, and gas conduits, etc. Noise may be generated 
in the communications lines which might cause communications glitches.

13. Cautions when Using the Product to Guarantee Safety

Содержание Switch-M8eGi Series

Страница 1: ...a loop detection history function which notifies when a loop occurs with the corresponding LED and enables a network administrator to identify the looped port after the loop is removed 6 Fanless desi...

Страница 2: ...e plate label Black 04 3 1 Power supply AC100 240V 50 60Hz 0 5A with a built in power supply 3 2 Power consumption 3 3 Operating environment Temperature 0 60 Humidity 20 80 RH no condensation 3 4 Stor...

Страница 3: ...EEE802 3az LPI When there is no data transmission at link up the energy saving state automatically starts so that power consumption can be reduced on each port Factory default Disable SFP extension sl...

Страница 4: ...lay for the connection with a connected terminal Status mode Display for the 1000 Mbps transmission rate GIGA mode Display for the 100Mbps or 10 Mbps transmission rate Speed mode Display for the full...

Страница 5: ...nk Off Green Light Off Port LED Left Right Port LED Left Port LED Right 5 Hardware Specifications Link is established Transmitting and receiving data No device connected Link is established at 1000Mbp...

Страница 6: ...on status can be checked using the following functions 1 Function to display the CPU 2 SFP module status checking function DDM Digital Diagnostic Monitoring 6 3 Rebooting 6 2 Switching Hub Control 6 4...

Страница 7: ...the power is turned OFF Loop shutoff time 60 to 86 400 sec Factory default setting 60 sec The set time Port LED lights up orange and the port shuts off Loop history retention time 3 days The LOOP HIS...

Страница 8: ...n EAP MD5 TLS PEAP Authentication method Web based authentication Mac based authentication using IEEE 802 1X Web based authentication Dynamic VLAN function using IEEE 802 1X Guest VLAN using IEEE 802...

Страница 9: ...mount brackets to the Switching Hub 8 8 Screw for fixing the connection bracket 8 9 Power cord CEE7 7 1 The attached power cord is dedicated for AC 100 240 V use 10 2 Accessories 8 2 2 Time setting SN...

Страница 10: ...125 m Multi Mode Fiber 62 5 125 m Multi Mode Fiber Maximum transmission distance 550 m at 50 125 m 220 m at 62 5 125 m 11 1 1000BASE SX SFP Module i Model No PN54022 ID 11 2 1000BASE LX SFP Module i...

Страница 11: ...orrosive and combustible gases Deviation could lead to fire electrical shock and or equipment failure 8 Do not place this Switching Hub under direct sunlight and or high temperature Deviation could le...

Страница 12: ...use the optical signal to not be transmitted normally and cause misoperations and malfunctions If they are contaminated make sure to clean them off then connect them to the optical fiber ports 9 This...

Страница 13: ...r use this Switching Hub in the environment in accordance with the specification High humidity Possible spilled liquid water Dusty Possible static charge such as carpet Under direct sunlight Possible...