NO
YES
NO
YES
NO
YES
NO
YES
1.3V
Traverse Operation
Traverse operation
Remains at inner track.
Remains at outer track.
Is IC10 pin 12
approx. 3.3 V?
Faulty traverse
detection switch S8
Is IC10 pin 12
approx. 0 V?
Faulty (shorted) traverse
detection switch S8
or
Is output of
IC3 pin 20 OK?
Is voltage
output between IC2
pins 15 and 16?
Faulty IC2
Faulty IC3
Faulty traverse motor