Fig. 17-4.
4. Confirm that the reading of the laser power meter is within the specified range. If it is not within the specified range,
adjust by turning
VR1
. Refer to
Fig. 17-5.
Fig. 17-5.
Specified range (read power): 600
µµµµ
W or lower
Caution:
Proceeding on to the subsequent adjustment procedure with the read power exceeding 600
µµµµ
W will result in
damage to the optical pickup.
5. Press “2” on the remote control transmitter.
“WRITE LASER” will be displayed to indicate the write power adjustment mode.
6. Confirm that the reading of the laser power meter is within the specified range. If it is not within the specified range,
adjust by turning
VR1
. Refer to
Fig. 17-5.
Specified range (write power): 4.8 mW±0.1 mW
Caution:
Do not allow the write power to even momentarily reach or exceed 5.5 mW. Doing so will result in damage to
43