SF4C Safety light curtain
2.6 Wiring
41
•
When this device is used in conformity with the Korean S-mark, the power
wire to be connected to this device should be less than 10m long.
Pin arrangement for emitter and receiver
Extension cable with connector on one end
Extension cable with connectors on both ends
Pin arrangement for emitter and receiver
Side A
Side B
Side A
Side A
Side B
Side A
Pin assignment on the A and B side connectors
Cable/connector
color
Pin No.
Lead wire color
Description
1
Pale purple
Interlock setting input
2 Brown
+V
3 Pink
Test
input/Reset
input
4
G
reen/Black
Auxiliary
output
5 Orange
Synchronization
+
6 Orange/Black Synchronization
-
7 Blue
0V
8
(Shield)
Output polarity setting wire
9
Gray
Safety input 1
10
Gray / Black
Safety input 2
11 Yellow
Override
input
Emitter
Gray/Gray
12
Red
Muting lamp output
1
White
Control output 2 (OSSD 2)
2 Brown
+V
3
Black
Control output 1 (OSSD 1)
4
G
reen
External device monitor input
5 Orange
Synchronization
+
6 Orange/Black Synchronization
-
7 Blue
0V
8
(Shield)
Output polarity setting wire
9
Gray
Large multi-purpose indicator
input 1
10
Gray / Black
Large multi-purpose indicator
input 2
11
Sky-blue / White
Muting input 1
Receiver
Gray (with black
stripe)/Black
12
Sky-blue / Black
Muting input 2
Rugghölzli 2