SF4C Safety light curtain
4.5 Using the Safety Input Function
95
4.5 Using the Safety Input Function
!
As safety sensor, use a sensor which incorporates a
crossover short-circuit function in the control output
and connect both the safety input 1 wire (gray) and
the safety input 2 wire (gray/black). If only one wire
is connected, the device may not operate normally.
The safety light curtain incorporates the safety input function. This function controls the control
output (OSSD1/2) of this device by receiving the detection signal of a safety contacting point
which is connected to the safety input 1 or 2.
Indicator symbol
Explanation
Lights up red
Lights up orange
Lights up green
Turns off
Indicators
Setting
procedure
Emitter
Receiver
Control
output
(OSSD 1,
OSSD 2)
Safety input ON
(Note 1)
RECEPTION
RECEPTION
ON
Safety input OFF
(Note 2)
RECEPTION
RECEPTION
OFF
Safety input error
Safety input 1:
Connected
Safety input 2: Not
connected
RECEPTION
RECEPTION
OFF
Safety input error
Safety input 1: Not
connected
Safety input 2:
Connected
RECEPTION
RECEPTION
OFF