(This “Safety Precaution” is applied only in U.S.A.)
1. Unplug the power cord and short the two prongs of the plug
with a jumper wire.
2. Turn on the power switch.
3. Measure the resistance value with ohmmeter between the
jumper AC plug and each exposed metal cabinet part, such
as screwheads, antenna, control shafts, handle brackets,
etc.
Equipment with antenna terminals should read between
2.7M
Ω
and 3.9M
Ω
to all exposed parts*. (Fig.1)
Equipment
without
antenna
terminals
should
read
approximately infinity to all exposed parts. (Fig.2)
*Note : Some exposed parts may be isolated from the
chassis by design. These will read infinity.
4. If the measurement is outside the specified limits, there is a
possibility of a shock hazard. The equipment should be
repaired and rechecked before it is returned to the
customer.
Fig.1
Fig.2
1 Safety Precaution
1. Before servicing, unplug the power cord to prevent an electric shock.
2. When replacing parts, use only manufacturer’s recommended components for safety.
3. Check the condition of the power cord. Replace if wear or damage is evident.
4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
5. Before returning the serviced equipment to the customer, be sure to make the following insulation resistance test to prevent the
customer from being exposed to a shock hazard.
1.1. Insulation Resistance Test
2 Before Repair and Adjustment
Disconnect AC power, discharge Power Supply Capacitors C520 and C540 through a 10
Ω
, 5W resistor to ground.
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
Current consumption at AC 120V, 60 Hz in NO SIGNAL mode should be ~600mA.
3
SA-AK110P /
Содержание SA-AK110P
Страница 7: ...7 Operation Procedures 7 SA AK110P ...
Страница 76: ...19 Troubleshooting Guide 76 SA AK110P ...
Страница 78: ...20 1 Deck Mechanism RAA4502 S 20 1 1 Deck Mechanism Parts Location 78 SA AK110P ...
Страница 79: ...79 SA AK110P ...
Страница 81: ...20 2 CD Loading Mechanism RD DAC026 S 20 2 1 CD Loading Mechanism Parts Location 81 SA AK110P ...
Страница 82: ...82 SA AK110P ...
Страница 84: ...20 3 1 Cabinet Parts Location 20 3 Cabinet 84 SA AK110P ...
Страница 85: ...85 SA AK110P ...
Страница 86: ...86 SA AK110P ...