9.7. Power Amplifier Failure (F61)
10 Description of Error Code
9.4. CD Mechanism Test (F15, F26, F16, F17, F27, F28, F29, H15)
1. Press “CD”.
2. Press “OPEN/CLOSE (1)” and place a CD.
3. Press “OPEN/CLOSE (1)” to close the tray.
4. Press “OPEN/CLOSE (5)” and wait until the tray is open.
5. Press “OPEN/CLOSE (1)” and remove the CD.
6. Press “OPEN/CLOSE (1)” to close the tray.
7. Press “
■
/STOP” to indicate Error Code.
•
If several problem exist, error code will change each time when “
■
/STOP” is pressed. (e.g. F15
→
F26
→
F16 ....etc).
9.5. To clear all Error code
1. Press “STOP/TUNE MODE” button for 5 seconds.
2. FL indicator shows “CLEAR” for 1 second and change to “T”.
9.6. How to get out from Self-Diagnostic function
1. Press “Power” button OFF.
1. When power amplifier fail, F61 will indicate automatically.
10.1. Error detection for Cassette Mechanism block
NO.
Error
Error
Display
Problem condition
1
MODE SW
detection error
H01
Faulty operation of cassette mechanism.
Faulty contact or short-circuit of mechanism mode switch (S951, S971).
2
REC INH SW
detection error
H02
Recording not possible.
Faulty contact or short-circuit of REC INH switch (S974, S975).
3
HALF SW
detection error
H03
Playback cannot perform.
Faulty contact or short-circuit of HALF siwtch (S952, S972).
4
Reel Pulse
detection error
H04
The tape advances slightly and then stops.
Faulty reel pulse, faulty hole detect IC (IC951, IC971).
5
TPS abnormal
F02
Cassette deck will not perform TPS function.
Faulty playback EQ/recording amplifier IC (IC101).
10.2. Error detection for CD/Changer block
NO.
Error
Error
Display
Problem condition
1
REST SW detection error
F15
CD does not function.
This error occurs when the Optical Pick Up REST SW (S701) is not
detected within the specified time (about 8 seconds)
2
CD tray opens automatically
F16
CLAMP switch (S4) NG (Check & Replace)
3
Does not startup when [PLAY]
button is pressed
F17
BOTTOM switch (S5) NG (Check & Replace)
4
Transmission error between CD
servo LSI and micon
F26
CD does not function.
This error occurs when the POWER is ON for the CD block and an error
is
detected after the transmission has started.
5
Startup fails even when you
insert CD or the selected disc tray
does not open
F27
Tray 1 detech switch or Tray 2 detech NG (Check & Rplace)
6
Cannot insert CD
F28
Tray 1 detech switch NG (Check & Replace)
7
Cannot eject CD
F29
Check if disc is stuck. Tray 2 detech switch NG (Confirm & Replace)
8
The CD tray closes
H15
CD disc tray detech switch NG (S3) (check & Replace)
10.3. Power Supply related error detection
NO
Error
Error
Display
Problem condition
1
POWER AMP
output abnormal
F16
When POWER is switched on, power become off automatically.
During normal operation, if DC DET become L, PCNT shall become
L and the error display on the left shall be displayed. (IC501)
36
SA-AK110P /
Содержание SA-AK110P
Страница 7: ...7 Operation Procedures 7 SA AK110P ...
Страница 76: ...19 Troubleshooting Guide 76 SA AK110P ...
Страница 78: ...20 1 Deck Mechanism RAA4502 S 20 1 1 Deck Mechanism Parts Location 78 SA AK110P ...
Страница 79: ...79 SA AK110P ...
Страница 81: ...20 2 CD Loading Mechanism RD DAC026 S 20 2 1 CD Loading Mechanism Parts Location 81 SA AK110P ...
Страница 82: ...82 SA AK110P ...
Страница 84: ...20 3 1 Cabinet Parts Location 20 3 Cabinet 84 SA AK110P ...
Страница 85: ...85 SA AK110P ...
Страница 86: ...86 SA AK110P ...