9 Self-Diagnostic Function
9.1. Self-diagnostic display
This unit is equipped with a self-diagnostic display function which, if a problem occurs, will display an error code corresponding to
the problem.
Use this function when performing maintenance on the unit.
9.2. How to enter the Self-Diagnostic Function
9.3. Cassette Mechanism Test (For error code H01, H02, H03, F01, F02)
1. Press “TAPE, DECK 1/2” to select Deck 2.
2. Load a cassette tape with the erasure prevention tab, remove from left side only and close the cassette holder.
3. Press “FAST FORWARD MEMORY” (Tape will be stop after 2 seconds)
4. Load a cassette tape with the erasure prevention tab, remove from right side only and close the cassette holder.
5. Press “REVERSE FM MODE/BP” (Tape will be stop after 2 seconds)
6. Load a pre-recorded tape with both side record tabs intact and close the cassette holder.
7. Press “PLAY/TUNE/TIME ADJ UP” (After TPS function, tape will stop automatically)
8. Press “REC/STOP” (Tape will not move)
9. Press “STOP/TUNE MODE” to indicate Error code.
•
If several problem exist, error code will change each time when “
■
/STOP” is pressed.
(e.g. H01
→
H03
→
F01 .....etc.)
10. Press “TAPE, DECK 1/2” to select Deck 1.
11. Repeat step 2 to 9 to test Deck 1. (Tape Deck 1 will not check H02 because of no recording function)
35
SA-AK110P /
Содержание SA-AK110P
Страница 7: ...7 Operation Procedures 7 SA AK110P ...
Страница 76: ...19 Troubleshooting Guide 76 SA AK110P ...
Страница 78: ...20 1 Deck Mechanism RAA4502 S 20 1 1 Deck Mechanism Parts Location 78 SA AK110P ...
Страница 79: ...79 SA AK110P ...
Страница 81: ...20 2 CD Loading Mechanism RD DAC026 S 20 2 1 CD Loading Mechanism Parts Location 81 SA AK110P ...
Страница 82: ...82 SA AK110P ...
Страница 84: ...20 3 1 Cabinet Parts Location 20 3 Cabinet 84 SA AK110P ...
Страница 85: ...85 SA AK110P ...
Страница 86: ...86 SA AK110P ...