background image

T

imers

S1DXM-A/M

 S1DXM-M multi-range timer

With MODE switch, Operation mode (switchable): Power ON-delay, Power Flicker OFF start, Power Flicker ON start, Power One-shot

Note: 48 V DC, 100 to 110 V DC, 24 V AC and 220 to 240 V AC types are made to order. Please inquire for details.

A socket line holding clip (ADX28005) is not included with the product. Please purchase separately.

Operating voltage

Time range

Timed-out 2 Form C

Timed-out 4 Form C

Part No.

Part No.

12V DC

0.05 s to 10 min

                 S1DXM-M2C10M-DC12V

                 S1DXM-M4C10M-DC12V

0.2 s to 30 min

                 S1DXM-M2C30M-DC12V

                 S1DXM-M4C30M-DC12V

0.5 s to 60 min

                 S1DXM-M2C60M-DC12V

                 S1DXM-M4C60M-DC12V

0.05 min to 10 hr

                 S1DXM-M2C10H-DC12V

                 S1DXM-M4C10H-DC12V

24V DC

0.05 s to 10 min

                 S1DXM-M2C10M-DC24V

                 S1DXM-M4C10M-DC24V

0.2 s to 30 min

                 S1DXM-M2C30M-DC24V

                 S1DXM-M4C30M-DC24V

0.5 s to 60 min

                 S1DXM-M2C60M-DC24V

                 S1DXM-M4C60M-DC24V

0.05 min to 10 hr

                 S1DXM-M2C10H-DC24V

                 S1DXM-M4C10H-DC24V

           24V AC  *Note

0.05 s to 10 min

                 S1DXM-M2C10M-AC24V

                 S1DXM-M4C10M-AC24V

0.2 s to 30 min

                 S1DXM-M2C30M-AC24V

                 S1DXM-M4C30M-AC24V

0.5 s to 60 min

                 S1DXM-M2C60M-AC24V

                 S1DXM-M4C60M-AC24V

0.05 min to 10 hr

                 S1DXM-M2C10H-AC24V

                 S1DXM-M4C10H-AC24V

100 to 120V AC

0.05 s to 10 min

                 S1DXM-M2C10M-AC120V

                 S1DXM-M4C10M-AC120V

0.2 s to 30 min

                 S1DXM-M2C30M-AC120V

                 S1DXM-M4C30M-AC120V

0.5 s to 60 min

                 S1DXM-M2C60M-AC120V

                 S1DXM-M4C60M-AC120V

0.05 min to 10 hr

                 S1DXM-M2C10H-AC120V

                 S1DXM-M4C10H-AC120V

200 to 220V AC

0.05 s to 10 min

                 S1DXM-M2C10M-AC220V

                 S1DXM-M4C10M-AC220V

0.2 s to 30 min

                 S1DXM-M2C30M-AC220V

                 S1DXM-M4C30M-AC220V

0.5 s to 60 min

                 S1DXM-M2C60M-AC220V

                 S1DXM-M4C60M-AC220V

0.05 min to 10 hr

                 S1DXM-M2C10H-AC220V

                 S1DXM-M4C10H-AC220V

           220 to 240V AC  *Note

0.05 s to 10 min

                 S1DXM-M2C10M-AC240V

                 S1DXM-M4C10M-AC240V

0.2 s to 30 min

                 S1DXM-M2C30M-AC240V

                 S1DXM-M4C30M-AC240V

0.5 s to 60 min

                 S1DXM-M2C60M-AC240V

                 S1DXM-M4C60M-AC240V

0.05 min to 10 hr

                 S1DXM-M2C10H-AC240V

                 S1DXM-M4C10H-AC240V

All Rights Reserved © C

OPYRIGHT

 Panasonic Electric Works Co., Ltd.

Содержание S1DXM-M

Страница 1: ...s to 60 min S1DXM A2C60M AC24V S1DXM A4C60M AC24V 0 05 min to 10 hr S1DXM A2C10H AC24V S1DXM A4C10H AC24V 100 to 120V AC 0 05 s to 10 min S1DXM A2C10M AC120V S1DXM A4C10M AC120V 0 2 s to 30 min S1DXM A2C30M AC120V S1DXM A4C30M AC120V 0 5 s to 60 min S1DXM A2C60M AC120V S1DXM A4C60M AC120V 0 05 min to 10 hr S1DXM A2C10H AC120V S1DXM A4C10H AC120V 200 to 220V AC 0 05 s to 10 min S1DXM A2C10M AC220V ...

Страница 2: ...r S1DXM M2C10H DC24V S1DXM M4C10H DC24V 24V AC Note 0 05 s to 10 min S1DXM M2C10M AC24V S1DXM M4C10M AC24V 0 2 s to 30 min S1DXM M2C30M AC24V S1DXM M4C30M AC24V 0 5 s to 60 min S1DXM M2C60M AC24V S1DXM M4C60M AC24V 0 05 min to 10 hr S1DXM M2C10H AC24V S1DXM M4C10H AC24V 100 to 120V AC 0 05 s to 10 min S1DXM M2C10M AC120V S1DXM M4C10M AC120V 0 2 s to 30 min S1DXM M2C30M AC120V S1DXM M4C30M AC120V 0...

Страница 3: ...nt Timed out 2 Form C Timed out 4 Form C Contact resistance Initial value Max 100mΩ at 1A 6V DC Contact material Timed out 2 Form C type Silver alloy Au plating Timed out 4 Form C type Silver alloy Au plating Life Mechanical constant Min 107 Electrical constant 2 105 at rated control capacity Mechanical Vibration resistance Functional 10 to 55Hz 1 cycle min single amplitude of 0 25mm 10min on 3 ax...

Страница 4: ... UP operation LED ON power LED orange OFF green ON OFF ON Power ON delay operation MODE switch 1 OFF switch 2 OFF When power is turned on the output contact operates after the set time The output contact remains on until the power is turned off Power Flicker OFF start operation MODE switch 1 OFF switch 2 ON When the power is turned on the output contacts repeatedly operate at the set time The outp...

Страница 5: ...iring diagram Timed out 2 Form C type Timed out 4 Form C type For the DC operating type terminal 14 is and terminal 13 is ON UP s m RANGE X1 X10 0 S1DXM Time range switch ON Power LED green Nameplate For 4 Form C type 28 5 1 122 16 6 654 Control time scale UP Operation LED orange 22 1 870 6 4 252 57 9 2 280 52 7 2 075 1 5 9 13 4 8 12 14 Operating voltage 13 35 526 1 5 9 2 6 10 3 7 11 13 4 8 12 14 ...

Страница 6: ...3 248 82 5 86 5 3 406 3 248 82 5 86 5 3 406 10 394 58 1 2 287 86 0 3 386 88 0 3 465 86 0 3 386 88 0 3 465 Notes The triangles indicate that removal will be slightly difficult when installed laterally in succession 1 The socket line holding clip ADX18005 is enclosed in the S1DX timer Available Not available 2 The socket line holding clip ADX28005 is not included with the S1DXM A M timer 3 For use w...

Страница 7: ...D K Available Not available 30 6 236 0 6 1 181 024 4 1 0 2 161 008 6 4 0 2 252 008 6 3 0 2 248 008 2 0 15 079 006 13 35 0 2 526 008 26 0 6 1 024 024 0 3 4 2 012 165 67 1 2 638 039 Terminal screw M3 21 0 6 827 024 4 1 14 12 8 13 9 5 4 157 26 30 26 1 024 1 024 30 1 181 1 181 33 5 1 319 67 2 638 10 394 Screw hole 2 M3 5 or 4 2 0 1 hole φ or 165 004 hole φ DIN high terminal socket HC4 HC4 SFD K Availa...

Страница 8: ... holes 59 1 2 323 039 72 1 2 835 039 30 1 181 16 5 650 3 4 0 3 134 012 35 4 1 394 4 157 6 0 3 236 012 22 866 4 1 8 5 9 12 13 14 HJ4 terminal socket HJ4 SFD Available Available 8 7 3 9 1 5 6 2 11 12 14 4 10 13 Lot No 30 1 181 16 5 650 3 4 0 3 134 012 35 4 0 5 1 394 020 6 0 3 236 012 M3 118 terminal screw 2 M4 2 5 165 5 mounting holes 59 1 2 323 039 72 1 2 835 039 29 1 142 1 2 3 7 6 5 8 12 11 10 9 1...

Страница 9: ...2 14 11 1 2 4 3 7 06 278 4 06 160 16 55 652 6 35 250 6 35 250 2 3 091 25 2 992 7 65 301 25 5 1 004 1 27 050 175 175 4 45 175 4 45 4 45 parallel installed 25 8 1 016 21 6 850 5 9 232 The interval size between the sockets which are The difference between the HC2 and HC4 sockets is only the number of the pins Their appearances and sizes are the same General tolerance 0 5 Dimensional tolerance of mach...

Страница 10: ...lding clip to secure terminal sockets and sockets to the timer unit The conditions of use for dedicated socket leaf holding clip will differ depending on the terminal socket or socket you will be using Therefore please test under actual conditions before putting into operation 3 If terminals are to be soldered directly please hand solder with a 30 to 60 W solder iron with a tip temperature of 300 ...

Страница 11: ... example when performing contact protection if set up like that of fig A leaking current will pass through C and R enter the timer and cause incorrect operation The fig B shows the correct setup When a contact switch having an operation indicating lamp lamp equipped limit switch etc is used to apply power to the timer a resistor having a value equal to or greater than the value below shall be conn...

Отзывы: