background image

Options

S1DXM-A/M/S1DX COMMON OPTIONS

 HC relay terminal sockets

Name/Model No.

• Terminal socket, HC

2-pin

HC2-SF-K

Available

Not

available

Dimensions

Terminal layout

Mounting hole dimensions

Applicable timers

S1DX(2c)

S1DXM(2c)

S1DX(4c)

S1DXM(4c)

6.2

.244

30

1.181

Oval hole: 2-4.2

×

5

.165

×

.197

12

.472

15

.591

40

1.575

5

.197

17.5

.689

Terminal screw M3

4

1

8

12 14

5

9

13

• High terminal socket,

HC 1-, 2- and 4-pin

HC4-HSF-K

Available

Available

For general rails

67

2.638

53.5

2.106

30

1.181

6.2

.244

9

.354

Oval hole: 2-4.2

×

9

.165

×

.354

22.5

.886

Screw
hole 
size

27.8

1.094

16

.630

8

.315

28.6

1.126

Terminal screw M3

3

7

4

8

1

11

12

14

5

9

13

6

2

10

• Slim DIN terminal

socket, HC2

HC2-SFD-S

Available

Not

available

Terminal screw M3

0.3

57

6.4

±

0.2

.252

±

.008

8

±

0.2

.315

±

.008

22

±

0.6

.866

±

.024

4.2

±

2

0.15

±

.079

.006

±

0.3

.165

±

.012

6.2

±

.012

.244

±

4.1

±

6.3

±

0.2

.161

±

.008

0.2

±

.248

.008

15

13.5

±

0.6

.591

±

.024

±

0.2

.531

±

.008

67

±

1

2.638

±

.039

6

0.6

28.5

±

.024

1.122

±

±

0.3

.236

±

.012

35.4

±

1

2.244

±

.039

0.6

20

±

.024

.787

±

±

0.5

1.394

±

.020

8

12

14

13

9

5

1

4

.079

22

.866

22

.866

0.2

15

±

.008

.591

±

0.2

15

±

.008

.591

±

.354

67

2.638

0.5

57

±

.020

2.244

±

Screw hole: 2-M3.5
(or    4.2

±

0.1 hole)

φ

(or    .165

±

.004 hole)

φ

• DIN high terminal

socket, HC2

HC2-SFD-K

Available

Not

available

30

6

.236

±

0.6

1.181

±

.024

4.1

±

0.2

.161

±

.008

6.4

±

0.2

.252

±

.008

6.3

±

0.2

.248

±

.008

2

±

0.15

.079

±

.006

13.35

±

0.2

.526

±

.008

26

±

0.6

1.024

±

.024

0.3

4.2

±

.012

.165

±

67

±

1

2.638

±

.039

Terminal screw M3

21

±

0.6

.827

±

.024

4

1

14

12

8

13

9

5

.157

26

30

26

1.024

1.024

30

1.181

1.181

33.5

1.319

67

2.638

10 

.394

Screw hole: 2-M3.5
(or    4.2

±

0.1 hole)

φ

(or    .165

±

.004 hole)

φ

• DIN high terminal

socket, HC4

HC4-SFD-K

Available

Available

For DIN rails

30

±

0.6

1.181

±

.024

6

.236

6.4

±

0.2

.252

±

.008

2

±

0.15

.079

±

.006

4.1

±

0.2

.161

±

.008

6.3

±

0.2

.248

±

.008

26

13.35

4.45

±

0.6

1.024

±

.024

±

0.2

.526

±

.008

±

0.2

.175

±

.008

0.3

4.2

±

.012

.165

±

67

±

1

2.638

±

.039

Terminal screw M3

21

±

0.6

.827

±

.024

12

14

8

11

10

9

13

7

6

5

4

3

2

1

Drilling size of panel holes for installing
the terminal sockets parallel

Note) Only socket line holding clips can be used.

(Socket leaf holding clip cannot be used.)

Note) Only socket line holding clips can be used.

(Socket leaf holding clip cannot be used.)

.472

.472

.906

12

12

23

40

1.575

30

30

1.181

1.181

5

.197

2-M.138 screw hole
(or .165

±

.004 dia. hole)

2-M3.5 screw hole
(or 4.2

±

0.1 dia. hole)

Panel hole dimensions for 
side-by-side mounting

22.5

22.5

.886

.886

53.5

2.106

2.638

67

30

30

1.181

1.181

5

.197

12.5

.492

2-M.138 screw hole
(or .165

±

.004 dia. hole)

2-M3.5 screw hole
(or 4.2

±

0.1 dia. hole)

Panel hole dimensions for 
side-by-side mounting

All Rights Reserved © C

OPYRIGHT

 Panasonic Electric Works Co., Ltd.

Содержание S1DXM-M

Страница 1: ...s to 60 min S1DXM A2C60M AC24V S1DXM A4C60M AC24V 0 05 min to 10 hr S1DXM A2C10H AC24V S1DXM A4C10H AC24V 100 to 120V AC 0 05 s to 10 min S1DXM A2C10M AC120V S1DXM A4C10M AC120V 0 2 s to 30 min S1DXM A2C30M AC120V S1DXM A4C30M AC120V 0 5 s to 60 min S1DXM A2C60M AC120V S1DXM A4C60M AC120V 0 05 min to 10 hr S1DXM A2C10H AC120V S1DXM A4C10H AC120V 200 to 220V AC 0 05 s to 10 min S1DXM A2C10M AC220V ...

Страница 2: ...r S1DXM M2C10H DC24V S1DXM M4C10H DC24V 24V AC Note 0 05 s to 10 min S1DXM M2C10M AC24V S1DXM M4C10M AC24V 0 2 s to 30 min S1DXM M2C30M AC24V S1DXM M4C30M AC24V 0 5 s to 60 min S1DXM M2C60M AC24V S1DXM M4C60M AC24V 0 05 min to 10 hr S1DXM M2C10H AC24V S1DXM M4C10H AC24V 100 to 120V AC 0 05 s to 10 min S1DXM M2C10M AC120V S1DXM M4C10M AC120V 0 2 s to 30 min S1DXM M2C30M AC120V S1DXM M4C30M AC120V 0...

Страница 3: ...nt Timed out 2 Form C Timed out 4 Form C Contact resistance Initial value Max 100mΩ at 1A 6V DC Contact material Timed out 2 Form C type Silver alloy Au plating Timed out 4 Form C type Silver alloy Au plating Life Mechanical constant Min 107 Electrical constant 2 105 at rated control capacity Mechanical Vibration resistance Functional 10 to 55Hz 1 cycle min single amplitude of 0 25mm 10min on 3 ax...

Страница 4: ... UP operation LED ON power LED orange OFF green ON OFF ON Power ON delay operation MODE switch 1 OFF switch 2 OFF When power is turned on the output contact operates after the set time The output contact remains on until the power is turned off Power Flicker OFF start operation MODE switch 1 OFF switch 2 ON When the power is turned on the output contacts repeatedly operate at the set time The outp...

Страница 5: ...iring diagram Timed out 2 Form C type Timed out 4 Form C type For the DC operating type terminal 14 is and terminal 13 is ON UP s m RANGE X1 X10 0 S1DXM Time range switch ON Power LED green Nameplate For 4 Form C type 28 5 1 122 16 6 654 Control time scale UP Operation LED orange 22 1 870 6 4 252 57 9 2 280 52 7 2 075 1 5 9 13 4 8 12 14 Operating voltage 13 35 526 1 5 9 2 6 10 3 7 11 13 4 8 12 14 ...

Страница 6: ...3 248 82 5 86 5 3 406 3 248 82 5 86 5 3 406 10 394 58 1 2 287 86 0 3 386 88 0 3 465 86 0 3 386 88 0 3 465 Notes The triangles indicate that removal will be slightly difficult when installed laterally in succession 1 The socket line holding clip ADX18005 is enclosed in the S1DX timer Available Not available 2 The socket line holding clip ADX28005 is not included with the S1DXM A M timer 3 For use w...

Страница 7: ...D K Available Not available 30 6 236 0 6 1 181 024 4 1 0 2 161 008 6 4 0 2 252 008 6 3 0 2 248 008 2 0 15 079 006 13 35 0 2 526 008 26 0 6 1 024 024 0 3 4 2 012 165 67 1 2 638 039 Terminal screw M3 21 0 6 827 024 4 1 14 12 8 13 9 5 4 157 26 30 26 1 024 1 024 30 1 181 1 181 33 5 1 319 67 2 638 10 394 Screw hole 2 M3 5 or 4 2 0 1 hole φ or 165 004 hole φ DIN high terminal socket HC4 HC4 SFD K Availa...

Страница 8: ... holes 59 1 2 323 039 72 1 2 835 039 30 1 181 16 5 650 3 4 0 3 134 012 35 4 1 394 4 157 6 0 3 236 012 22 866 4 1 8 5 9 12 13 14 HJ4 terminal socket HJ4 SFD Available Available 8 7 3 9 1 5 6 2 11 12 14 4 10 13 Lot No 30 1 181 16 5 650 3 4 0 3 134 012 35 4 0 5 1 394 020 6 0 3 236 012 M3 118 terminal screw 2 M4 2 5 165 5 mounting holes 59 1 2 323 039 72 1 2 835 039 29 1 142 1 2 3 7 6 5 8 12 11 10 9 1...

Страница 9: ...2 14 11 1 2 4 3 7 06 278 4 06 160 16 55 652 6 35 250 6 35 250 2 3 091 25 2 992 7 65 301 25 5 1 004 1 27 050 175 175 4 45 175 4 45 4 45 parallel installed 25 8 1 016 21 6 850 5 9 232 The interval size between the sockets which are The difference between the HC2 and HC4 sockets is only the number of the pins Their appearances and sizes are the same General tolerance 0 5 Dimensional tolerance of mach...

Страница 10: ...lding clip to secure terminal sockets and sockets to the timer unit The conditions of use for dedicated socket leaf holding clip will differ depending on the terminal socket or socket you will be using Therefore please test under actual conditions before putting into operation 3 If terminals are to be soldered directly please hand solder with a 30 to 60 W solder iron with a tip temperature of 300 ...

Страница 11: ... example when performing contact protection if set up like that of fig A leaking current will pass through C and R enter the timer and cause incorrect operation The fig B shows the correct setup When a contact switch having an operation indicating lamp lamp equipped limit switch etc is used to apply power to the timer a resistor having a value equal to or greater than the value below shall be conn...

Отзывы: