background image

T

imers

S1DXM-A/M

Part names

Dimensions 

(mm 

inch

)

Time range 
switch

Time range 
switch

Setting dial

Operation LED 
(orange)

Power LED

(green)

Setting

 hand

Control time

scale

S1DXM-M

S1DXM-A

Operation

mode switch

• [RANGE] Time range switch
  (4 different time ranges can be switched.)

• [MODE] Operation mode switch 
  (4 different operation modes can be switched.)

Power ON-delay
Power Flicker OFF start
Power Flicker ON start
Power One-shot

10M type:
30M type:
60M type:
10H type:

1 s/10 s/1 min/10 min
3 s/30 s/3 min/30 min
6 s/60 s/6 min/60 min
1 min/10 min/1 hr/10 hr

The CAD data of the products with a    

CAD Data

    mark can be downloaded from: http://panasonic-electric-works.net/ac

 S1DXM-A

Terminal layouts and Wiring diagram

                         Timed-out 2 Form C type

                         Timed-out 4 Form C type

       * For the DC operating type, terminal 14 is “+” and terminal 13 is “–”.

ON

UP

s

m

RANGE

X1

X10

0

S1DXM

Time range switch

ON (Power) LED (green)

Nameplate

For 4 Form C type

28.5

1.122

16.6

.654

Control time scale

UP (Operation) LED (orange)

22.1

.870

6.4

.252

57.9

2.280

52.7

2.075

1

5

9

13

4

8

12

14

Operating

voltage

13.35

.526

1

5

9

2

6

10

3

7

11

13

4

8

12

14

Operating

voltage

5.1

.201

4.1

.161

6.4

.252

6.4

.252

13.35

.526

.175

4.45

Note: Please also refer to “PRECAUTIONS IN USING S1DXM-A/M AND S1DX” on page 68.

 S1DXM-M

ON

UP

MODE

ON

s

m

RANGE

X1

X10

2

1

0

S1DXM

Time range switch

Operation mode switch

ON (Power) LED (green)

Nameplate

For 4 Form C type

Control time scale

UP (Operation) LED (orange)

22.1

.870

28.5

1.122

6.4

.252

57.9

2.280

52.7

2.075

16.6

.654

CAD Data

Tolerance: 

±

0.5 

±

.020

CAD Data

All Rights Reserved © C

OPYRIGHT

 Panasonic Electric Works Co., Ltd.

Содержание S1DXM-M

Страница 1: ...s to 60 min S1DXM A2C60M AC24V S1DXM A4C60M AC24V 0 05 min to 10 hr S1DXM A2C10H AC24V S1DXM A4C10H AC24V 100 to 120V AC 0 05 s to 10 min S1DXM A2C10M AC120V S1DXM A4C10M AC120V 0 2 s to 30 min S1DXM A2C30M AC120V S1DXM A4C30M AC120V 0 5 s to 60 min S1DXM A2C60M AC120V S1DXM A4C60M AC120V 0 05 min to 10 hr S1DXM A2C10H AC120V S1DXM A4C10H AC120V 200 to 220V AC 0 05 s to 10 min S1DXM A2C10M AC220V ...

Страница 2: ...r S1DXM M2C10H DC24V S1DXM M4C10H DC24V 24V AC Note 0 05 s to 10 min S1DXM M2C10M AC24V S1DXM M4C10M AC24V 0 2 s to 30 min S1DXM M2C30M AC24V S1DXM M4C30M AC24V 0 5 s to 60 min S1DXM M2C60M AC24V S1DXM M4C60M AC24V 0 05 min to 10 hr S1DXM M2C10H AC24V S1DXM M4C10H AC24V 100 to 120V AC 0 05 s to 10 min S1DXM M2C10M AC120V S1DXM M4C10M AC120V 0 2 s to 30 min S1DXM M2C30M AC120V S1DXM M4C30M AC120V 0...

Страница 3: ...nt Timed out 2 Form C Timed out 4 Form C Contact resistance Initial value Max 100mΩ at 1A 6V DC Contact material Timed out 2 Form C type Silver alloy Au plating Timed out 4 Form C type Silver alloy Au plating Life Mechanical constant Min 107 Electrical constant 2 105 at rated control capacity Mechanical Vibration resistance Functional 10 to 55Hz 1 cycle min single amplitude of 0 25mm 10min on 3 ax...

Страница 4: ... UP operation LED ON power LED orange OFF green ON OFF ON Power ON delay operation MODE switch 1 OFF switch 2 OFF When power is turned on the output contact operates after the set time The output contact remains on until the power is turned off Power Flicker OFF start operation MODE switch 1 OFF switch 2 ON When the power is turned on the output contacts repeatedly operate at the set time The outp...

Страница 5: ...iring diagram Timed out 2 Form C type Timed out 4 Form C type For the DC operating type terminal 14 is and terminal 13 is ON UP s m RANGE X1 X10 0 S1DXM Time range switch ON Power LED green Nameplate For 4 Form C type 28 5 1 122 16 6 654 Control time scale UP Operation LED orange 22 1 870 6 4 252 57 9 2 280 52 7 2 075 1 5 9 13 4 8 12 14 Operating voltage 13 35 526 1 5 9 2 6 10 3 7 11 13 4 8 12 14 ...

Страница 6: ...3 248 82 5 86 5 3 406 3 248 82 5 86 5 3 406 10 394 58 1 2 287 86 0 3 386 88 0 3 465 86 0 3 386 88 0 3 465 Notes The triangles indicate that removal will be slightly difficult when installed laterally in succession 1 The socket line holding clip ADX18005 is enclosed in the S1DX timer Available Not available 2 The socket line holding clip ADX28005 is not included with the S1DXM A M timer 3 For use w...

Страница 7: ...D K Available Not available 30 6 236 0 6 1 181 024 4 1 0 2 161 008 6 4 0 2 252 008 6 3 0 2 248 008 2 0 15 079 006 13 35 0 2 526 008 26 0 6 1 024 024 0 3 4 2 012 165 67 1 2 638 039 Terminal screw M3 21 0 6 827 024 4 1 14 12 8 13 9 5 4 157 26 30 26 1 024 1 024 30 1 181 1 181 33 5 1 319 67 2 638 10 394 Screw hole 2 M3 5 or 4 2 0 1 hole φ or 165 004 hole φ DIN high terminal socket HC4 HC4 SFD K Availa...

Страница 8: ... holes 59 1 2 323 039 72 1 2 835 039 30 1 181 16 5 650 3 4 0 3 134 012 35 4 1 394 4 157 6 0 3 236 012 22 866 4 1 8 5 9 12 13 14 HJ4 terminal socket HJ4 SFD Available Available 8 7 3 9 1 5 6 2 11 12 14 4 10 13 Lot No 30 1 181 16 5 650 3 4 0 3 134 012 35 4 0 5 1 394 020 6 0 3 236 012 M3 118 terminal screw 2 M4 2 5 165 5 mounting holes 59 1 2 323 039 72 1 2 835 039 29 1 142 1 2 3 7 6 5 8 12 11 10 9 1...

Страница 9: ...2 14 11 1 2 4 3 7 06 278 4 06 160 16 55 652 6 35 250 6 35 250 2 3 091 25 2 992 7 65 301 25 5 1 004 1 27 050 175 175 4 45 175 4 45 4 45 parallel installed 25 8 1 016 21 6 850 5 9 232 The interval size between the sockets which are The difference between the HC2 and HC4 sockets is only the number of the pins Their appearances and sizes are the same General tolerance 0 5 Dimensional tolerance of mach...

Страница 10: ...lding clip to secure terminal sockets and sockets to the timer unit The conditions of use for dedicated socket leaf holding clip will differ depending on the terminal socket or socket you will be using Therefore please test under actual conditions before putting into operation 3 If terminals are to be soldered directly please hand solder with a 30 to 60 W solder iron with a tip temperature of 300 ...

Страница 11: ... example when performing contact protection if set up like that of fig A leaking current will pass through C and R enter the timer and cause incorrect operation The fig B shows the correct setup When a contact switch having an operation indicating lamp lamp equipped limit switch etc is used to apply power to the timer a resistor having a value equal to or greater than the value below shall be conn...

Отзывы: