background image

1

SIMPLEXA 601 top

6010140

307561 01

Time switch

EN

1.  Basic safety information

Danger of death through electric shock or fire!

 

¾

Installation should only be carried out by a 

qualified electrician!

WARNING

 

The device is designed for installation on DIN top hat 
rails (in accordance with EN 60715)

 

The device corresponds to type 1 STU in accordance with 
IEC/EN 60730-2-7

2.  Proper use

 

The time switch is used for lighting, ventilation and 

flushing applications etc.

 

Only for use in closed, dry rooms

 

!

Do not use on safety devices, e.g. escape route doors, fire 
safety equipment etc.

Disposal

 

†

Dispose of device in environmentally sound manner

3.  Installation and connection

Mounting the time switch

clic

 

†

Mount on DIN top hat rails (as defined in EN 60715)

 

†

Switched voltage-free

 

†

Ensure device cannot be switched on

 

†

Check absence of voltage

 

†

Earth and bypass

 

†

Cover or shield any adjacent live components

Connecting the time switch

C1

1 2 N

N

L

L

L

 

!

Correct connection (see wiring diagram) required for 

smooth function of the zero-cross switching.

4.  Device description

Display & buttons

0

6

12

18

24

MENU

OK

OK

MENU

Programmed  

switching times

Date display

Channel status  

On

Off

Time display
Days of the week 

from 1 to 7

Display of the active buttons 

with the relevant function

– Activate display

– Open menu

– Cancel menu

– ESC  

  (leave menu)

– Save  

 selection 

– Confirm  

 selection

¾

 

  

Options 

are displayed

Содержание 6010140

Страница 1: ...spose of device in environmentally sound manner 3 Installation and connection Mounting the time switch clic Mount on DIN top hat rails as defined in EN 60715 Switched voltage free Ensure device cannot...

Страница 2: ...MODIFY DELETE END MEM FREE 42 ON HOUR MINUTE MONDAY SAVE COPY ADD TUESDAY u u SAVE u u LA switching time always consists of a start time and an end time LThere are 42 memory cells available Example S...

Страница 3: ...or programmed switching Permanent switching As long as a permanent switching on or off is activated the programmed switching times are ineffective ok Activating manual control Briefly press both butt...

Страница 4: ...4 7 Contact Theben AG Hohenbergstr 32 72401 Haigerloch GERMANY Tel 49 7474 692 0 Fax 49 7474 692 150 Hotline Tel 49 7474 692 369 hotline theben de Addresses telephone numbers etc www theben de...

Страница 5: ...sic safety information 4 2 Proper use 4 Disposal 4 3 Installation and connection 5 Mounting the time switch 5 Connecting the cable 7 Disconnecting the cable 7 4 Device description 8 Display buttons 8...

Страница 6: ...itching times 14 Delete switching program 15 Setting holiday function 16 Activating PIN code 17 Setting manual or permanent switching 17 Hour counter 18 Using Bluetooth OBELISK top3 18 Connect time sw...

Страница 7: ...3 6 Technical data 23 7 Contact 24...

Страница 8: ...ion on DIN top hat rails in accordance with EN 60715 The device corresponds to type 1 STU in accordance with IEC EN 60730 2 7 2 Proper use The time switch is used for lighting ventilation and flushing...

Страница 9: ...ion Mounting the time switch clic Mount on DIN top hat rails as defined in EN 60715 Switched voltage free Ensure device cannot be switched on Check absence of voltage Earth and bypass Cover or shield...

Страница 10: ...6 Connecting the time switch C1 1 2 N N L L L Correct connection see wiring diagram required for smooth function of the zero cross switching...

Страница 11: ...witching times Date display Channel status On Off Time display Days of the week from 1 to 7 Display of the active buttons with the relevant function Activate display Open menu Cancel menu ESC leave me...

Страница 12: ...8 YES Confirmation Press OK NO Modify Change Press t u 1 Read text line text symbol represents query 2 Make a decision...

Страница 13: ...OPTIONS END TIME SET DATE SU WI WEEK DAY FORM DATE FORM TIME END LANGUAGE PIN FACTORY SETTINGS INFO END MENU u u u NEW CHECK MODIFY DELETE END Initial operation LThe device must be connected to the po...

Страница 14: ...SK SUOMI SVENSKA HEBREW u DEUTSCH FORM DATE YEAR MONTH DAY FORM TIME HOUR MINUTE SU WI EUROPE 24 02 20 off 9 4046 Set language date time as well as summer winter time SU WI Press any button and displa...

Страница 15: ...time for one day PROGRAM MENU NEW CHECK MODIFY DELETE END MEM FREE 42 ON HOUR MINUTE MONDAY SAVE COPY ADD TUESDAY u u SAVE u u LA switching time always consists of a start time and an end time LThere...

Страница 16: ...firm with OK ADD TUESDAY is displayed confirm by pressing OK and also confirm the days We Th Fr by pressing OK Continue with until SAVE is displayed Confirm by pressing OK Repeat all steps for the tur...

Страница 17: ...elect PROGRAM and press OK to confirm Select MODIFY confirm by pressing OK Select day confirm with OK MODIFY HOUR use the or buttons to change hour and minute and confirm with OK To change several swi...

Страница 18: ...yed with DELETE ALL confirm with OK MONDAY is displayed confirm with OK Select DELETE BLOCK confirm with OK With DELETE MONDAY etc individual days can also be cleared Activating PIN code The PIN code...

Страница 19: ...hing As long as a permanent switching on or off is activated the programmed switching times are ineffective ok Activating manual control Briefly press both buttons simultaneously Activating permanent...

Страница 20: ...phase is permitted Shortest switching time 1 min Switching accuracy accurate to the second Protection rating IP 20 in accordance with EN 60529 Protection class II in accordance with EN 60730 1 subject...

Страница 21: ...es EVG 600 W LED lamps 2 W 30 W LED lamps 2 W 300 W LThe time switch display is only fully functional at tempera tures from 5 C 55 C 7 Contact Theben AG Hohenbergstr 32 72401 Haigerloch GERMANY Tel 49...

Страница 22: ...18...

Страница 23: ...19...

Страница 24: ...20...

Страница 25: ...21...

Страница 26: ...22...

Страница 27: ...23...

Страница 28: ...24...

Отзывы: