1-4
1.2 Restrictions
1.2.1 Installation Position of S-LINK Units
The maximum of 4 S-LINK units can be installed as expansion units in the position to the left
of and adjacent to the FP
Σ
control unit.
No. of control I/O points
Types of control unit
No. of I/O points
for control unit
No. of I/O points when
FP
Σ
S-LINK unit is installed.
FPG-C32T2/FPG-C32T2TM
Note1)
32 points
Max. 640 points
Note2)
FPG-C28P2/FPG-C28P2TM
28 points
Max. 636 points
Note2)
FPG-C24R2/FPG-C24R2TM
24 points
Max. 632 points
Note1) The FP
Σ
expansion unit cannot be fitted to the FPG-C32T or FPG-C32TTM.
Note2) It is the No. of points when 4 FP
Σ
S-LINK units have been installed.
Key Point:
If the FP0 expansion unit and the FP
Σ
expansion unit are used together, the I/O points can be extended
up to 640 points for the FPG-C32T2/FPG-C32T2TM.