background image

3

E

NGLISH

This appliance is intended to be used 

by expert or trained users in shops, 

in light industry and on farms, or for 

commercial use by lay persons.
This appliance can be used by 

children aged from 8 years and 

above and persons with reduced 

physical, sensory or mental 

capabilities or lack of experience and 

knowledge if they have been given 

supervision or instruction concerning 

use of the appliance in a safe 

way and understand the hazards 

involved.
Keep the fire alarm and the air outlet 

at least 1.5m away from the unit.
Do not cool or heat the room too 

much if babies or invalids are 

present.
Do not turn the Air-to-Water on and 

off from the power mains switch. Use 

the ON/OFF operation button.
Do not stick anything into the air 

outlet of the outdoor unit. This 

is dangerous because the fan 

is rotating at high speed.
Do not touch the air inlet or the 

sharp aluminum fins of the 

outdoor unit. You may get 

injured.
Do not sit or step on the unit. 

You may fall down accidentally.
Do not stick any object 

into the FAN CASE. You 

may be injured and the 

unit may be damaged.

Provide a power outlet to be used 

exclusively for each unit, and a 

power supply disconnect, Earth 

Leakage Circuit Breaker (ELCB) 

or Residual Current Device (RCD) 

for overcurrent protection should 

be provided in the exclusive line.
Provide a power outlet 

exclusively for each unit, and full 

disconnection means having a 

contact separation in all poles 

must be incorporated in the fixed 

wiring in accordance with the 

wiring rules.
To prevent possible hazards 

from insulation failure, the 

unit must be grounded.
Do not use modified 

cord, joint cord, 

extension cord or 

unspecified cord to prevent 

overheating and fire. 

Stop using the product when any 

abnormality/failure occurs and 

disconnect the power plug or turn 

off the power switch and breaker.

(Risk of smoke/fire/electric shock)

Examples of abnormality/failure:

• The ELCB trips frequently.

• The product sometimes does not 

start when turned on.

• The power is sometimes 

disconnected when the cord is 

moved.

• Burnt odor or abnormal noise is 

detected during operation.

• The body is deformed or 

abnormally hot.

• Water leaks from the indoor unit.

• Power cord or plug becomes 

abnormally hot.

• Fan speed cannot be controlled.

• The unit stops running 

immediately even if it is switched 

on for operation.

• The fan does not stop even if the 

operation is stopped.

Contact immediately your local 

dealer for maintenance/repair.

WARNING

CAUTION

• The compressor may occasionally stop during thunderstorms.

This is not a mechanical failure. The unit automatically 

recovers after a few minutes.

• The English text is the original instructions. Other languages 

are translation of the original instructions.

Important Information Regarding

The Refrigerant Used

This product contains fluorinated greenhouse gases covered 

by the Kyoto Protocol. Do not vent gases into the atmosphere.
Refrigerant type: R410A
GWP

(1)

 value: 1975

(1)

 GWP = global warming potential

Periodical inspections for refrigerant leaks may be required 

depending on European or local legislation. Please contact 

your local dealer for more information.

NOTICE

OI_00_271368_Eng.indb   3

2015-7-2   9:14:18

Содержание S-80MW1E5

Страница 1: ...la unidad lea atentamente estas instrucciones de funcionamiento y gu rdelas para futuras consultas DEUTSCH 38 49 Bevor Sie das Ger t in Betrieb nehmen lesen Sie bitte diese Bedienungsanleitung aufmer...

Страница 2: ...omes in contact with a flame it produces a toxic gas For safety be sure to turn the Air to Water off and also to disconnect the power before cleaning or servicing Pull off the power plug from a recept...

Страница 3: ...n accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded Do not use modified cord joint cord extension cord or unspecified cord to prevent overh...

Страница 4: ...C operate only Air to Water unit Tips for Energy Saving Avoid z z Do not block the air intake and outlet or water intake and outlet of the unit If either is obstructed the unit will not function well...

Страница 5: ...lected content Press centre No glove No pen Start Stop button Starts Stops operation Operation indicator Illuminates during operation Blinks during alarm Cross key buttons Selects an item Note Menu bu...

Страница 6: ...t Temperature Icon Description Internal heater is active Internal heater is abnormal Internal heater is manually in process Internal heater is not in process Control to prevent water freezing is activ...

Страница 7: ...epeat Press 2 times to finish Clock type 4 Select the type to display Press 2 times to finish Operation lock 4 Select the type of lock and set to Press 2 times to finish To cancel lock Select in step...

Страница 8: ...off Operation indicator SET TEMP 7 20 30 THU AIR CONDITIONING MODE HEAT MODE HEAT SET TEMP 7 20 30 THU AIR CONDITIONING SET TEMP 7 20 30 THU AIR CONDITIONING MODE COOL Under Heating Curve Control To...

Страница 9: ...heating capacity will be limited z z When operation started Indoor unit fan stops for maximum 6 minutes z z When Thermostat activated z z When defrosting When Heating Operation Started Only 3WAY VRF...

Страница 10: ...than temperature for sterilization the set temperature is displayed Under Sterilization Stop sterilization Under unavoidable circumstances this function is enabled when the Air to Water unit must be s...

Страница 11: ...arget water out temperature It is only displayed information It is not able to change the target water out temperature by the centralized controller Int heater forced ON The internal heater of Air to...

Страница 12: ...s for Energy Saving P 4 The room is exposed to direct sunlight in cooling mode Doors or windows are open Too many heat sources in cooling mode Use minimum heat sources and in a short time Too many peo...

Страница 13: ...Steam comes out during heating operation The fan continues to rotate even after the operation is stopped using the remote controller This is for smooth operation Error code Code How to Release E03 Rem...

Страница 14: ...230 240 V 50Hz Cooling capacity kW 8 0 12 5 BTU h 27 000 42 700 Heating capacity kW 9 0 14 0 BTU h 30 000 47 800 Sound Pressure level dB A 37 40 Sound Power level dB A 50 53 Unit Dimensions H W D mm 8...

Страница 15: ...3WAY tipo MF2 3WAY Typ MF2 English Italiano Nederlands Portugu s Air to Water Heatpump Type W1 Sottile a condotto a bassa pressione statica tipo W1 Slim lage statische druk kanaal type W1 Est tica ba...

Страница 16: ...del Name Modello Modelnaam Nome do modelo Power Source Fonte di alimentazione Voeding Fonte de alimenta o Cooling Capacity Capacit di raffreddamento Koelingscapaciteit Capacidade de arrefecimento Heat...

Страница 17: ...125 MEMO OI_00_271368_Eng indb 125 2015 7 2 9 14 30...

Страница 18: ...126 MEMO OI_00_271368_Eng indb 126 2015 7 2 9 14 30...

Страница 19: ...127 MEMO OI_00_271368_Eng indb 127 2015 7 2 9 14 30...

Страница 20: ...sonic com Printed in Malaysia Panasonic Corporation 2015 F570002 BE0715 0 Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany...

Отзывы: