background image

2

z

z

Safety Precautions

 ........................................................... 2

z

z

Precautions for Use

 ......................................................... 4

z

z

Names of Parts

 ................................................................. 5

z

z

Initial Settings

 .................................................................. 7

z

z

Operation

 .......................................................................... 8

• Operation Mechanism

 ................................................... 9

z

z

Function of Air-to-Water Unit

 ........................................ 10

z

z

Maintenance

 ................................................................... 12

• Before Requesting Services

 ....................................... 12

z

z

Troubleshooting

 ............................................................. 13

z

z

Specifications

 ............................................................... 122

• Indoor unit

 .................................................................. 122

• Corresponding language table

 ................................. 123

Contents

Safety Precautions

Product Information

If you have problems or questions concerning your Air-to-

Water, you will need the following information. Model and 

serial numbers are on the nameplate on the lid of the electrical 

component box.

Model No. 

Serial No. 

Date of purchase

Dealer’s address

Phone number

Confirm to authorized dealer 

or specialist on usage of 

specified refrigerant type. Using 

of refrigerant other than the 

specified type may cause product 

damage, burst and injury etc.
This Air-to-Water has no ventilator 

for intaking fresh air from 

outdoors. You must open doors or 

windows frequently when you use 

gas or oil heating appliances in 

the same room, which consume a 

lot of oxygen from the air. 

Otherwise there is a risk of 

suffocation in an extreme case.
Never use or store gasoline or 

other flammable vapor or liquid 

near the Air-to-Water — it is very 

dangerous.
Do not use this appliance in a 

potentially explosive atmosphere.
Never touch the unit with wet hands.
Do not insert your fingers or 

other objects into the Air-to-

Water indoor or outdoor 

unit, rotating parts may cause 

injury.

If the refrigerant comes in contact 

with a flame, it produces a toxic 

gas.
For safety, be sure to turn the 

Air-to-Water off and also to 

disconnect the power before 

cleaning or servicing.
Pull off the power plug from  

a receptacle, or switch off  

the breaker, or switch off the 

power disconnecting mean to 

isolate the Air-to-Water from the 

main power supply in case of 

emergency.
Do not clean inside the indoor and 

outdoor units by users. Engage 

authorized dealer or specialist for 

cleaning.
In case of malfunction of this 

appliance, do not repair by yourself. 

Contact to the sales dealer or 

service dealer for a repair.

The following symbols used in this manual, alert you to 

potentially dangerous conditions to users, service personnel or 

the appliance:

WARNING

This symbol refers to a hazard or 

unsafe practice which can result in 

severe personal injury or death.

CAUTION

This symbol refers to a hazard or 

unsafe practice which can result 

in personal injury or product or 

property damage.

Prohibited matters

Matters to be  

observed

Thank you for purchasing this Panasonic product.

This product is a commercial Air-to-Water unit.

Installation Instructions attached.

Be sure to read the operating instructions relevant to the 

VRF system connected to this Air-to-Water and all appliances 

connected to the VRF system. 

• Read these Operating Instructions carefully before using 

this Air-to-Water. If you still have any difficulties or problems, 

consult your dealer for help.

• This Air-to-Water is designed to give you comfortable 

room conditions. Use this only for its intended purpose as 

described in these Operating Instructions.

WARNING

OI_00_271368_Eng.indb   2

2015-7-2   9:14:17

Содержание S-80MW1E5

Страница 1: ...la unidad lea atentamente estas instrucciones de funcionamiento y gu rdelas para futuras consultas DEUTSCH 38 49 Bevor Sie das Ger t in Betrieb nehmen lesen Sie bitte diese Bedienungsanleitung aufmer...

Страница 2: ...omes in contact with a flame it produces a toxic gas For safety be sure to turn the Air to Water off and also to disconnect the power before cleaning or servicing Pull off the power plug from a recept...

Страница 3: ...n accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded Do not use modified cord joint cord extension cord or unspecified cord to prevent overh...

Страница 4: ...C operate only Air to Water unit Tips for Energy Saving Avoid z z Do not block the air intake and outlet or water intake and outlet of the unit If either is obstructed the unit will not function well...

Страница 5: ...lected content Press centre No glove No pen Start Stop button Starts Stops operation Operation indicator Illuminates during operation Blinks during alarm Cross key buttons Selects an item Note Menu bu...

Страница 6: ...t Temperature Icon Description Internal heater is active Internal heater is abnormal Internal heater is manually in process Internal heater is not in process Control to prevent water freezing is activ...

Страница 7: ...epeat Press 2 times to finish Clock type 4 Select the type to display Press 2 times to finish Operation lock 4 Select the type of lock and set to Press 2 times to finish To cancel lock Select in step...

Страница 8: ...off Operation indicator SET TEMP 7 20 30 THU AIR CONDITIONING MODE HEAT MODE HEAT SET TEMP 7 20 30 THU AIR CONDITIONING SET TEMP 7 20 30 THU AIR CONDITIONING MODE COOL Under Heating Curve Control To...

Страница 9: ...heating capacity will be limited z z When operation started Indoor unit fan stops for maximum 6 minutes z z When Thermostat activated z z When defrosting When Heating Operation Started Only 3WAY VRF...

Страница 10: ...than temperature for sterilization the set temperature is displayed Under Sterilization Stop sterilization Under unavoidable circumstances this function is enabled when the Air to Water unit must be s...

Страница 11: ...arget water out temperature It is only displayed information It is not able to change the target water out temperature by the centralized controller Int heater forced ON The internal heater of Air to...

Страница 12: ...s for Energy Saving P 4 The room is exposed to direct sunlight in cooling mode Doors or windows are open Too many heat sources in cooling mode Use minimum heat sources and in a short time Too many peo...

Страница 13: ...Steam comes out during heating operation The fan continues to rotate even after the operation is stopped using the remote controller This is for smooth operation Error code Code How to Release E03 Rem...

Страница 14: ...230 240 V 50Hz Cooling capacity kW 8 0 12 5 BTU h 27 000 42 700 Heating capacity kW 9 0 14 0 BTU h 30 000 47 800 Sound Pressure level dB A 37 40 Sound Power level dB A 50 53 Unit Dimensions H W D mm 8...

Страница 15: ...3WAY tipo MF2 3WAY Typ MF2 English Italiano Nederlands Portugu s Air to Water Heatpump Type W1 Sottile a condotto a bassa pressione statica tipo W1 Slim lage statische druk kanaal type W1 Est tica ba...

Страница 16: ...del Name Modello Modelnaam Nome do modelo Power Source Fonte di alimentazione Voeding Fonte de alimenta o Cooling Capacity Capacit di raffreddamento Koelingscapaciteit Capacidade de arrefecimento Heat...

Страница 17: ...125 MEMO OI_00_271368_Eng indb 125 2015 7 2 9 14 30...

Страница 18: ...126 MEMO OI_00_271368_Eng indb 126 2015 7 2 9 14 30...

Страница 19: ...127 MEMO OI_00_271368_Eng indb 127 2015 7 2 9 14 30...

Страница 20: ...sonic com Printed in Malaysia Panasonic Corporation 2015 F570002 BE0715 0 Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany...

Отзывы: