Outputting All Results (Output = All)
When the Handshake Function Is Set to “No”
Inspection data are output at intervals of set “Output signal guarantee time (Tp)”. STRB signal turns on each time
outputting the data.Receive data with the external device after rising edge of STRB ON signal and before the next STRB
signal turns on.
The following is an example of outputting data dividing into two times in Serial mode.
Tf: 400µs (fixed), Tp (1-1000ms): Data output guarantee time (default: 10 ms)
1. As the inspection ends, the first data (OUT signal) is output through I/O interface and turned on
STRB signal and TACT signal.
Obtain the first result after more than 1 ms of wait time when STRB signal turns on.
The time from when STRB signal turns on till when the result output (OUT signal) is determined varies
according to the condition of the connected load or ambient temperature.
2. STRB signal turns off after the time of Tp passes.
3. As the time of Tp passed from STRB signal turns off, the second data is output and STRB
signal and REDY signal turn on(*).
Obtain the second result after more than 2 ms of wait time when STRB signal turns on.
When synchronous output is operated in addition to I/O output, including data output to COM port and Ethernet port,
and inspection image output, READY signal stays OFF until the operation is completed.
4. STRB signal and TACT signal turn off after the time of Tp passes. Setting "Parallel I/O Output
Reset Condition" to "Reset" resets OUT signal at this timing.
5. I/O result output is complete after the time of "Tp+Tf" passes from TACT signal turns off.
You cannot output the next result while the time of "Tp+Tf" is passing in Parallel mode, and the device is in the
status of waiting for output.