Camera No.: 

C0 – C1 (2 digits) Number of the camera which captured the image. (Automatically added) 

Scan Count:   

Scan count: 7 digits (Automatically added) 

 

Scan Count is reset to “0” by turning on the power, switching type, and resetting statistics data. If 
the file name of the image to be output after reset is the same as the file name that has been output 
before reset, it will be overwritten. Adding time or type number to the additional information 
prevents the file names to be the same.) 

1.

  Select "Set" in "Image file setting", and enter "File Header" with the software keyboard. 

Default: “Image_” 

2.

  Select an item from four types for “Additional Information 0” to “Additional Information 4”. 

Select "None" when no additional information is needed. 

 

Maximum number of digits for a file name is 50. 

Selecting Compression Rate of Output Image 

1.

  Select from "None", "1/2", "1/4" and "1/8" in "Compression". 

Compression rate 

Captured image size 

Output image size 

Output time 

None 

640 x 480 pixels 

640 x 480 pixels 

 

1/2 

320 x 240 pixels 

Approx. 1/2 of the case 
of "None" 

1/4 

160 x 120 pixels 

Approx. 1/4 of the case 
of "None" 

1/8 

80 x 60 pixels 

Approx. 1/8 of the case 
of "None" 

 

Compressed images can be automatically decompressed and retrieved with PV-T30 and PVWIN-T30. 
However, note that the resolution deteriorates. 
When the used camera is 0.3-Meaga Compact Color Camera (ANPVC6030), the image size is 640 x 478 
pixels, however, the inspection is performed with an image of 640 x 480 pixels. The missing vertical two 
pixels are filled with black pixels (Gray level 0). It is the same state as when partial imaging is set with 
another camera.   

Selecting a Format to Output Color Images 

1.

  Select "Bayer Img.    (.byr)" or "RGB Img. (.bmp)" in "Color Image Format". 

 

Bayer image is an image saved in the same array as an image sensor of a color camera. 
As the file size is small and the time for saving is shortened, you should use Bayer Image to save 
many images. 
Files saved in this format (.byr) cannot be confirmed with general applications such as a PC. 
Bayer images can be confirmed on PV-T30, PVWIN-T30 or PVImageConverter. Its files size is smaller 
than that of RGB image (.bmp). 

 

Содержание PV-T30

Страница 1: ...PVWIN T30 PV T30 instructions manual Support documentation Nov 24 2015 ...

Страница 2: ...urned on after the period of Tf When executing synchronous output data output to COM port and Ethernet port or image output as well as I O output REDY signal stays OFF until these outputs complete After REDY signal turns ON the device can receive the next STRT signal Obtain a result after more than 1 ms of wait time when TACT signal turns on The time from when TACT signal turns on till when the re...

Страница 3: ... on after the period of Tf Obtain a result after more than 1 ms of wait time when TACT signal turns on The time from when TACT signal turns on till when the result output OUT signal is determined varies according to the condition of the connected load or ambient temperature 5 TACT signal turns on for the time of Tp and then turns off for the time of Tp Tf You cannot output the next result while th...

Страница 4: ... and allows capturing the third image after the second image capturing or the first synchronous result output general output through I O and synchronously whichever completed later before outputting the general result and the image of the first inspection is completed ...

Страница 5: ...utput OUT signal is determined varies according to the condition of the connected load or ambient temperature 2 STRB signal turns off after the time of Tp passes 3 As the time of Tp passed from STRB signal turns off the second data is output and STRB signal and REDY signal turn on Obtain the second result after more than 2 ms of wait time when STRB signal turns on When synchronous output is operat...

Страница 6: ...signal in the time of To 5 PV T30 outputs the second last data in 100μsec Td after turning off ACK signal 6 As the time of Tf passed from data output turn on STRB signal and REDY signal When synchronous output is operated in addition to I O output including data output to COM port and Ethernet port and inspection image output REDY signal stays OFF until the operation is completed 7 As for an exter...

Страница 7: ...lt In addition the reversed value of judgment of JDC001 is automatically referred to JDC001 Creating a Calculation 1 Select INSPECTION Judgement from the menu bar Judgement window is displayed 2 Select a type of Judgement to set by Type Judgement has two types as below Select them in accordance with your purpose JDC External The judgement result can be output to the external device JRC Internal Th...

Страница 8: ...esults totally 5 Enter an operation expression Up to 16 items and 560 characters can be set If you selected a wrong item delete it with the F2 key and reregister the expression Moving the cursor onto an item displays the information of the item in the expression explanation field 6 Enter a comment with the software keyboard as necessary 7 After inputting is completed press the CANCEL key 8 Press t...

Страница 9: ...his condition expression is common to all cameras When judgement is NG all images of the cameras which is set to Output will be output Selecting a Condition Expression of Inspection Image Output 1 Select Condition in judgement output setting window Condition setting window is displayed 2 Select Condition column of Image Output Select a judgement type to register No Images are not output No Conditi...

Страница 10: ...of available value is 1 to 1000 3 Set Overwrite No Default Terminates image saving Yes Deletes the oldest folder and all images stored in the folder and creates a new folder to continue saving when the number of folders reaches the limit or the space of a SD memory card is used up Outputting through Ethernet interface 1 Select Ethernet from the selectmenu Environment Setting Input Output Image Out...

Страница 11: ...ted Because the time of outputting images is included its inspection time is longer than the other two options Asynchronous image output first An inspection is complete before outputting images and then PV T30 outputs images when it can When the interval of START signal input the period between inspection start and the next inspection start is short and Image Output is not completed after several ...

Страница 12: ...ixels 640 x 480 pixels 1 2 320 x 240 pixels Approx 1 2 of the case of None 1 4 160 x 120 pixels Approx 1 4 of the case of None 1 8 80 x 60 pixels Approx 1 8 of the case of None Compressed images can be automatically decompressed and retrieved with PV T30 and PVWIN T30 However note that the resolution deteriorates When the used camera is 0 3 Meaga Compact Color Camera ANPVC6030 the image size is 64...

Отзывы: