120 - ENGLISH
Chapter 6 Appendix — Technical information
r
r
Error response
Error message
Termination symbol
“ERR1”
Undefined control command
(CR)
0x0d
“ERR2”
Out of parameter range
“ERR3”
Busy state or no-acceptable period
“ERR4”
Timeout or no-acceptable period
“ERR5”
Wrong data length
“ERRA”
Password mismatch
4 bytes
1 byte
When WEB control administrator rights password is not set (Non-protect mode)
Connection method
1)
Obtain the IP address and port number (Initial
set value = 1024) of the projector and request
for a connection to the projector.
r
f
You can obtain both the IP address and the port number from
the menu screen of the projector.
IP address
Obtain from the main menu
→
[NETWORK]
→
[NETWORK STATUS].
Port number
Obtain from the main menu
→
[NETWORK]
→
[NETWORK CONTROL]
→
[COMMAND PORT].
2)
Check the response from the projector.
r
r
Response data
Data section
Blank
Mode
Termination symbol
“NTCONTROL”
(ASCII string)
‘ ’
0x20
‘0’
0x30
(CR)
0x0d
9 bytes
1 byte
1 byte
1 byte
r
f
Mode: 0 = Non-protect mode
Command transmission method
Transmit using the following command formats.
r
r
Transmitted data
Header
Data section
Termination symbol
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
1 byte
1 byte
Undefined length
1 byte
r
r
Received data
Header
Data section
Termination symbol
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
1 byte
1 byte
Undefined length
1 byte