background image

 

 
 
 
 
 
 
 
 
 

 

Thank you for purchasing our product. 

 

This manual provides you with important information about safe and 
proper operations of this Switching Hub. 

 

Please read the "Important Safety Warnings" on pages 3 to 4. 

 

Any problems or damage resulting from disassembly of this Switching 
Hub by customers are note covered by the warranty. 

 

Applicable product names and model numbers are described on page 2. 

 

 

Layer 2 Switching Hub 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Model  Number:  PN28080i/PN28160i 

  PN28240i

 

Operation Manual 

for CLI 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание PN28080i

Страница 1: ...hing Hub Please read the Important Safety Warnings on pages 3 to 4 Any problems or damage resulting from disassembly of this Switching Hub by customers are note covered by the warranty Applicable product names and model numbers are described on page 2 Layer 2 Switching Hub Model Number PN28080i PN28160i PN28240i Operation Manual for CLI ...

Страница 2: ...uct name Model No Firmware version Switch M8eGi PN28080i ID PN28080i TH PN28080i MY PN28080i SG 3 0 0 00 or higher Switch M16eGi PN28160i ID PN28160i TH PN28160i MY PN28160i SG 3 0 0 00 or higher Switch M24eGi PN28240i ID PN28240i TH PN28240i MY PN28240i SG 3 0 0 00 or higher ...

Страница 3: ...ing a thunderstorm Deviation could lead to electric shock Do not disassemble and or modify this Switching Hub Deviation could lead to fire electric shock and or equipment failure Do not damage the power cord Do not bend too tightly stretch twist bundle with other cord pinch put under a heavy object and or heat it Damaged power cord could lead to fire short and or electric shock Do not put foreign ...

Страница 4: ...b at the location with continuous vibration or strong shock or at the unstable location Deviation could lead to injury and or equipment failure Do not install any module other than the separately sold SFP module PN54022 PN54024 to SFP extension slot Deviation could lead to fire electric shock and or equipment failure Do not put this Switching Hub into fire Deviation could lead to explosion and or ...

Страница 5: ...er port Deviation could lead to electric fire shock and or malfunction Unplug the power cord if the STATUS ECO LED Status ECO mode blinks in orange system fault Deviation such as keeping connected for a long time could lead to fire When this Switching Hub is installed on wall surface mount it firmly so as not to drop down because of weight of the main body and connection cable Deviation could lead...

Страница 6: ...ace charged objects in the proximity of them Static electricity could lead to equipment failure Do not put the modular plug of the connected twisted pair cable on objects that can carry static charge such as carpet Do not place it in the proximity Static electricity could lead to equipment failure Do not put a strong shock including dropping to this Switching Hub Deviation could lead to equipment ...

Страница 7: ...al SFP extension modules PN54022 PN54024 is inserted into the SFP extension slot For the latest information about compatible SFP extension modules check our website 1 Panasonic will not be liable for any damage resulting from the operation not in accordance with this document or the loss of communications which may or may not be caused by failure and or malfunction of this product 2 The contents d...

Страница 8: ...ation 163 3 8 ARP Configuration 174 4 Advanced Switch Configuration 180 4 1 VLAN Configuration 180 4 1 1 Internet Mansion Function Configuration 194 4 2 Link Aggregation Configuration 200 4 2 1 About Link Aggregation 200 4 3 Port Monitoring Configuration 206 4 4 Access Control Configuration 211 4 5 QoS Quality of Service Configuration 235 4 6 Bandwidth Control Configuration 242 4 7 Storm Control C...

Страница 9: ...iguration 406 9 Ping Execution 409 10 System Log Display 412 11 Save and Display of Configuration Information 423 12 Obtaining Technical Support Information 428 Appendix A Specifications 431 Appendix B Easy IP Address Setup Function 432 Appendix C Example of Network Configuration using Loop Detection Function and Its Precautions 433 Appendix D MIB List 435 Troubleshooting 440 After sales Service 4...

Страница 10: ...lows you to set individual items such as each port and each VLAN in detail Fig 1 1 Command hierarchy enable Command Enter this command to switch from the User mode to the Privileged mode M24eGi User mode M24eGi enable User mode Privileged mode M24eGi Privileged mode M24eGi disable Privileged mode User mode M24eGi User mode disable Command Enter this command to switch from the Privileged mode to th...

Страница 11: ...Global configuration mode Interface configuration mode vlan1 M24eGi config if exit Interface configuration mode Global configuration mode M24eGi config interface Gigabitethernet0 1 Global configuration mode Interface configuration mode interface1 M24eGi config if exit Interface configuration mode Global configuration mode M24eGi config Global configuration mode exit Command Enter this command to r...

Страница 12: ...nter this command to return to the menu screen from any command mode M24eGi config logout Configuration mode Menu Command Enter a question mark to view available commands in that command mode Fig 1 2 command Command History Support Press the up arrow key to view the history of the entered commands M24eGi enable Privilege level to go to exit Exit from current mode logout To logout from the CLI shel...

Страница 13: ...sh ru Bad Example of Abbreviated Command Entry co Because both configure and copy are possible an error occurs Symbols used in the command description are as follows Required You must enter this Selections Select one from the selections Option Enter as required Commands are case sensitive Uppercase and lower case letters are treated as different letters Note that in this manual ports are specified...

Страница 14: ...ation up time and version information M24eGi show sys info Command to show the address information MAC address and IP address information M24eGi show ip conf Command to show the ipv6 address information MAC address and IPv6 address information M24eGi show ipv6 conf Command to show the CPU information CPU utilization information M24eG show cpuload Command Entry Example ...

Страница 15: ...4eGi enable M24eGi show sys info System up for 0 days 0 1 29 Boot Code Version 1 00 17 Runtime Code Version 1 0 0 07 Serial Number xxxxxxxxxxx Hardware Information Version A1 DRAM Size 128MB Fixed Baud Rate 9600bps FLASH Size 32MB Administration Information Switch Name Switch Location Switch Contact System Address Information MAC Address 00 C0 8F A0 13 98 IP Address 0 0 0 0 Subnet Mask 0 0 0 0 Def...

Страница 16: ...on 11 Switch Name Shows the Switching Hub s current host name 12 Switch Location Shows the Switching Hub s current installation location name 13 Switch Contact Shows the Switching Hub s current contact information 14 System Address Information Shows the Switching Hub s address information 15 MAC Address Shows the Switching Hub s MAC address 16 IP Address Shows the Switching Hub s current IP addres...

Страница 17: ... function is disabled 20 IPv6 Address prefixlen Shows the Switching Hub s current ipv6 address and prefix length in operation 21 IPv6 Link Local Address Shows the Switching Hub s current ipv6 link local address in operation 22 IPv6 Default Gateway Shows the Switching Hub s current ipv6 default gateway in operation ...

Страница 18: ...s the Switching Hub s MAC address 2 IP Address Shows the Switching Hub s current IP address in operation 3 Subnet Mask Shows the Switching Hub s current subnet mask in operation 4 Default Gateway Shows the Switching Hub s current default gateway in operation M24eGi enable M24eGi show ip conf MAC Address 00 C0 8F A0 13 98 IP Address 0 0 0 0 Subnet Mask 0 0 0 0 Default Gateway 0 0 0 0 M24eGi 1 2 3 4...

Страница 19: ...bled 2 MAC Address Shows the Switching Hub s MAC address 3 IPv6 Address prefixlen Shows the Switching Hub s current IPv6 address in operation 4 IPv6 Link Local Address Shows an Ipv6 link local address in operation which is configured on the Switching Hub 5 IPv6 Default Gateway Shows the Switching Hub s current IPv6 default gateway in operation M24eGi enable M24eGi show ipv6 conf IPv6 Status Disabl...

Страница 20: ...he command below Fig 2 4 Example of executing the command to show CPU information 1 CPU Utilization Indicates the CPU utilization of the Switching Hub which is calculated by taking five seconds one minute or five minutes M24eG show cpuload CPU Utilization Five seconds 7 One minute 7 Five minutes 7 M24eG ...

Страница 21: ...rmation such as up time and version information Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 22: ...None None Setting Range Parameter name Setting range None None Note Parameter name Note None None show ipv6 conf Shows the ipv6 address information such as MAC address and IPv6 address of the Switching Hub Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name N...

Страница 23: ... CPU utilization of the Switching Hub Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 24: ...m information M24eGi show sys info Command to set the host name M24eGi config hostname hostname Command to delete the host name M24eGi config no hostname Command to set the installation location M24eGi config snmp server location server location Command to delete the installation location M24eGi config no snmp server location Command to set the contact information M24eGi config snmp server contact...

Страница 25: ...ing Hub s current installation location name M24eGi enable M24eGi show sys info System up for 0 days 0 1 29 Boot Code Version 1 00 17 Runtime Code Version 1 0 0 07 Hardware Information Version A1 DRAM Size 128MB Fixed Baud Rate 9600bps FLASH Size 32MB Administration Information Switch Name Switch Location Switch Contact System Address Information MAC Address 00 C0 8F A0 13 98 IP Address 0 0 0 0 Su...

Страница 26: ...26 4 Switch Contact Shows the Switching Hub s current contact information ...

Страница 27: ... system information Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 28: ...g Parameter name Factory default setting hostname None Setting Range Parameter name Setting range hostname Up to 50 one byte characters Allowed characters alphanumeric character A Z a z 0 9 symbol _ white space Note Parameter name Note hostname To set a system name containing white spaces enclose the entire name with a pair of double quotation marks Example hostname switch a ...

Страница 29: ...on location Factory Default Setting Parameter name Factory default setting server location None Setting Range Parameter name Setting range server location Up to 50 one byte characters Allowed characters alphanumeric character A Z a z 0 9 symbol _ white space Note Parameter name Note server location To set a location name containing white spaces enclose it with a pair of double quotation marks Exam...

Страница 30: ...Default Setting Parameter name Factory default setting server contact None Setting Range Parameter name Setting range server contact Up to 50 one byte characters Allowed characters alphanumeric character A Z a z 0 9 symbol _ white space Note Parameter name Note server contact To set contact information containing white spaces enclose it with a pair of double quotation marks Example snmp server con...

Страница 31: ...ch 2 Set this Switching Hub s installation location to Office 2F 3 Set this Switching Hub s contact information to manager Fig 3 1 2 Example of configuring the Switching Hub s administration information M24eGi enable M24eGi configure M24eGi config hostname Switch Switch config snmp server location Office 2F Switch config snmp server contact manager Switch config exit Switch 1 2 3 ...

Страница 32: ... 1 1 Username and Password Configuration Configure the username and password for this Switching Hub in Global configuration mode Command to set the username and password M24eGi config username new username ...

Страница 33: ...tion new username Enter a new username Enter the current username to keep the same name Factory Default Setting Parameter name Factory default setting new username None Setting Range Parameter name Setting range new username 0 to 12 one byte characters Allowed characters alphanumeric character A Z a z 0 9 symbol _ Note Parameter name Note new username None Note Make sure to remember the changed or...

Страница 34: ... the current password The factory default setting is manager 3 Enter a new password 4 Enter the new password again Fig 3 1 1 1 Example of the username and password configuration M24eGi enable M24eGi configure M24eGi config username user1 Enter old password Enter new password Enter new password again M24eGi config 1 2 3 4 ...

Страница 35: ...ddress ip address mask default gateway Command to delete the IP address M24eGi config no ip address Command to set the IPv6 enable M24eGi config ipv6 enable Command to delete the IPv6 enable M24eGi config no ipv6 enable Command to set the IPv6 address M24eGi config Ipv6 address ipv6 address prefixlen prefixlen gateway Command to delete the IPv6 address M24eGi config no Ipv6 address Command to set ...

Страница 36: ...ws the Switching Hub s MAC address 2 IP Address Shows the Switching Hub s current IP address in operation 3 Subnet Mask Shows the Switching Hub s current subnet mask in operation 4 Default Gateway Shows the Switching Hub s current default gateway in operation M24eGi enable M24eGi show ip conf MAC Address 00 C0 8F A0 13 98 IP Address 0 0 0 0 Subnet Mask 0 0 0 0 Default Gateway 0 0 0 0 M24eGi 1 2 3 ...

Страница 37: ...unction is disabled 2 MAC Address Shows the Switching Hub s MAC address 3 IPv6 Address prefixlen Shows the Switching Hub s current IPv6 address in operation 4 IPv6 Link Local Address Shows the Switching Hub s current ipv6 link local address in operation 5 IPv6 Default Gateway Shows the Switching Hub s current IPv6 default gateway in operation M24eGi show ipv6 conf IPv6 Status Disable MAC Address 0...

Страница 38: ... Factory default setting ip address 0 0 0 0 mask 0 0 0 0 default gateway 0 0 0 0 Setting Range Parameter name Setting range ip address 0 0 0 1 to 223 255 255 254 mask 128 0 0 0 to 255 255 255 255 One bits and zero bits must be consecutive in binary default gateway 0 0 0 1 to 223 255 255 254 Note Parameter name Note ip address None mask None default gateway None Note The above items must be set in ...

Страница 39: ...39 ...

Страница 40: ...y to 192 168 1 254 Fig 3 2 3 Example of the address configuration 1 M24eGi enable M24eGi configure M24eGi config ip address 192 168 1 1 255 255 255 0 192 168 1 254 Interface vlan1 my HWaddr 00 c0 8f a0 13 98 my IPaddr 192 168 1 1 Options subnet mask 255 255 255 0 IP broadcast 192 168 1 255 gateway 192 168 1 254 M24eGi config ...

Страница 41: ...s the IPv6 stack Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None no ipv6 enable The IPv6 stack is disabled Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 42: ...Parameter name Factory default setting ipv6 address 0 0 prefixlen 128 default gateway 0 0 Setting Range Parameter name Setting range ipv6 address 2 to FE7F FFFF FFFF FFFF FFFF FFFF FFFF FFFF FEC0 to FEFF FFFF FFFF FFFF FFFF FFFF FFFF FFFF prefixlen 1 to 128 default gateway 2 FEFF FFFF FFFF FFFF FFFF FFFF FFFF FFFF Note Parameter name Note ipv6 address None prefixlen None gateway None Note The abov...

Страница 43: ...43 ...

Страница 44: ...ss Enter an IPv6 link local address to be set or edited Factory Default Setting Parameter name Factory default setting ipv6 link local address The switch automatically assigns itself ipv6 link local address EUI 64 format when ipv6 is enabled Setting Range Parameter name Setting range ipv6 link local address FE80 to FEBF FFFF FFFF FFFF FFFF FFFF FFFF FFFF Note Parameter name Note ipv6 link local ad...

Страница 45: ...ss to 2001 100 prefix length to 64 and ipv6 default gateway to 2001 1 Fig 3 2 4 Example of the ipv6 address configuration 1 M24eGi enable M24eGi configure M24eGi config ipv6 enable M24eGi config ipv6 address 2001 100 prefixlen 64 2001 1 M24eGi config exit M24eGi ...

Страница 46: ... the SNMP trap type IP address community name M24eGi config no snmp server host id Command to create the SNMP group M24eGi config snmp server group string v1 v2c v3 Command to delete the SNMP group M24eGi config no snmp server group string v1 v2c v3 Command to set the read write notify view for the SNMP group M24eGi config snmp group read write notify string Command to set the seculity level for t...

Страница 47: ...and to set the SNMP trap cold start M24eGi config snmp server enable traps snmp coldstart Command to delete the SNMP trap cold start M24eGi config no snmp server enable traps snmp coldstart Command to set the SNMP trap notification of port link up down status M24eGi config snmp server enable traps linkupdown 1 2 or 1 2 3 or 1 2 3 5 Command to delete the SNMP trap notification of port link up down ...

Страница 48: ...0 0 0 ro 6 Disabled 0 0 0 0 ro 7 Disabled 0 0 0 0 ro 8 Disabled 0 0 0 0 ro 9 Disabled 0 0 0 0 ro 10 Disabled 0 0 0 0 ro No IPv6 Address 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0 7 0 0 8 0 0 9 0 0 10 0 0 Trap Reciever List No Status IP Address Version Trap Community String 1 Enabled 0 0 0 0 v1 public 2 Disabled 0 0 0 0 v1 3 Disabled 0 0 0 0 v1 4 Disabled 0 0 0 0 v1 5 Disabled 0 0 0 0 v1 6 Disabled 0 0 0 ...

Страница 49: ...he SNMP manager Enabled Access by the SNMP manager for the entry number is enabled Disabled Access by the SNMP manager for the entry number is disabled 5 IP Destination Shows the IP address of the SNMP manager 6 Access Shows the access privilege of the SNMP manager Ro Read only is allowed Rw Both read and write are allowed No IPv6 Address 1 2001 1 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0 7 0 0 8 0 0 9 0 0 10...

Страница 50: ...bled Disabled The SNMP trap receiver for the entry number is disabled 12 IP Destination Shows the IP address of the SNMP trap receiver 13 Version Shows the SNMP trap type v1 SNMP v1 traps are sent v2 SNMP v2 traps are sent 14 Trap Community String Shows the current community name used for sending SNMP traps 15 IPv6 Destination Shows the IPv6 address of the SNMP trap receiver 16 Individual Trap Sho...

Страница 51: ... The SNMP authentication failure trap is disabled 19 Login Failure Shows the status of SNMP login failure trap Enabled The SNMP login failure trap is enabled Disabled The SNMP login failure trap is disabled 20 Enable Link Up Down Port Shows the port number to which the trap is sent when the link status changes All indicates that all ports are targeted ...

Страница 52: ...v2c NoAuth NoPriv initial v3 NoAuth NoPriv private v1 NoAuth NoPriv private v2c NoAuth NoPriv Group Name Read View Name public CommunityView public CommunityView initial restricted private CommunityView private CommunityView Group Name Write View Name public None public None initial None private CommunityView private CommunityView Group Name Notify View Name public CommunityView public CommunityVi...

Страница 53: ...on 2C v3 SNMP version 3 4 Security level Shows the Security level for the SNMP group NoAuth NoPriv No authentication no privacy Auth Priv Authentication privacy Auth NoPriv Authentication no privacy 5 Read View Name Shows the Read View Name for the SNMP group 6 Write View Name Shows the Write View Name for the SNMP group 7 Notify View Name Shows the Notify View Name for the SNMP group ...

Страница 54: ...user information 1 Number Shows the entry number assigned to the SNMP user 2 User Name Shows the SNMP user name 3 Group name Shows the SNMP group name for the SNMP user M24eGi show snmp server user SNMP User List No User Name Group 1 initial initial 2 test public 3 4 5 6 7 8 9 10 No User Name Auth Pri 1 initial None None 2 test MD5 DES 3 4 5 6 7 8 9 10 M24eGi 1 2 3 4 5 ...

Страница 55: ...ntication Protocol for the SNMP user None None MD5 Use HMAC MD5 algorithm for authentication SHA Use HMAC SHA algorithm for authentication 5 Privacy Protocol Shows the Privacy Protocol for the SNMP user None None DES Use DES encryption algorithm ...

Страница 56: ...w subtree OID 4 View Type Shows the View type for the SNMP view Included OID is included into the view Excluded OID is excluded from the view M24eGi show snmp server view Total Entry 8 View Name Subtree View Type restricted 1 3 6 1 2 1 1 Included restricted 1 3 6 1 2 1 11 Included restricted 1 3 6 1 6 3 10 2 1 Included restricted 1 3 6 1 6 3 11 2 1 Included restricted 1 3 6 1 6 3 15 1 1 Included C...

Страница 57: ...nfiguration information Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 58: ...bles the SNMP agent Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None no snmp server agent The SNMP agent is disabled Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 59: ...the SNMP manager string Set the SNMP View name to access control Factory Default Setting Parameter name Factory default setting id No 1 to 2 Enabled No 3 to 10 Disabled community No 1 private No 2 public ro rw Privilege No 1 Read Write No 2 to 10 Read Only ip address 0 0 0 0 ipv6 address 0 0 string No 1 CommunityView No 2 CommunityView Setting Range Parameter name Setting range id 1 to 10 communit...

Страница 60: ...60 Note Parameter name Note None ...

Страница 61: ...s of the SNMP trap receiver string Set the community name or the SNMP user name for the SNMP trap receiver Factory Default Setting Parameter name Factory default setting id None The SNMP trap receiver setting is disabled v1 v2c v3 None ip address 0 0 0 0 ipv6 address 0 0 string None Setting Range Parameter name Setting range id 1 to 10 v1 v2c v3 Either v1 or v2 or v3 ip address Class A 1 x x x to ...

Страница 62: ... Parameter name Description string Set the SNMP group name v1 v2c v3 Set the type of the SNMP group Factory Default Setting Parameter name Factory default setting string public private v1 v2c v3 public v1 private v1 Setting Range Parameter name Setting range string Up to 32 one byte characters v1 v2c v3 Either v1 or v2c or v3 Note Parameter name Note None ...

Страница 63: ...notify the notify view for the SNMP group This command is executed in the SNMP group configuration mode Parameter Parameter name Description string Set the SNMP view name Factory Default Setting Parameter name Factory default setting string CommunityView Setting Range Parameter name Setting range string Up to 32 one byte characters Note Parameter name Note None ...

Страница 64: ...iv Set the security level for the SNMP group Factory Default Setting Parameter name Factory default setting noauth_nopriv auth_nopriv auth_priv public CommunityView Read Notify private CommunityView Read Write Notify Setting Range Parameter name Setting range noauth_nopriv auth_nopriv auth_priv noauth_nopriv no authentication no private auth_nopriv authentication no private auth_priv authenticatio...

Страница 65: ...ings Parameter Parameter name Description 1 10 Set the entry number of the SNMP user string Set the SNMP user name Factory Default Setting Parameter name Factory default setting 1 10 1 string initial Setting Range Parameter name Setting range 1 10 1 to 10 string Up to 32 one byte characters Note Parameter name Note None ...

Страница 66: ...the SNMP user configuration mode Parameter Parameter name Description string Set the SNMP group name Factory Default Setting Parameter name Factory default setting string public private initial Setting Range Parameter name Setting range string Up to 32 one byte characters Note Parameter name Note None ...

Страница 67: ...d5 sha Set the authentication method for the SNMP user string Set the password or encrypted key Factory Default Setting Parameter name Factory default setting md5 sha None string None Setting Range Parameter name Setting range md5 sha MD5 or SHA string MD5 8 to 16 one byte characters or 32 one byte characters Encrypted SHA 8 to 20 one byte characters or 40 one byte characters Encrypted Note Parame...

Страница 68: ...d is executed in the SNMP user configuration mode Parameter Parameter name Description string Set the password or encrypted key Factory Default Setting Parameter name Factory default setting string None Setting Range Parameter name Setting range string DES 8 to 20 one byte characters or 32 one byte characters Encrypted Note Parameter name Note None ...

Страница 69: ...Parameter Parameter name Description ip address Set the ip address for the SNMP user Factory Default Setting Parameter name Factory default setting ip address 0 0 0 0 Setting Range Parameter name Setting range ip address Class A 1 x x x to 126 x x x Class B 128 1 x x to 191 254 x x Class C 192 0 1 x to 223 255 254 x Note Parameter name Note None ...

Страница 70: ...NMP user configuration mode Parameter Parameter name Description ipv6 address Set the ipv6 address for the SNMP user Factory Default Setting Parameter name Factory default setting ipv6 address 0 0 Setting Range Parameter name Setting range ip address 2 to FEFF FFFF FFFF FFFF FFFF FFFF FFFF FFFF Note Parameter name Note None ...

Страница 71: ...tes the SNMP view settings Parameter Parameter name Description string Set the SNMP view name Factory Default Setting Parameter name Factory default setting string restricted CommunityView Setting Range Parameter name Setting range string Up to 32 one byte characters Note Parameter name Note None ...

Страница 72: ...uded OID is excluded from the view Factory Default Setting Parameter name Factory default setting oid included excluded Restricted 1 3 6 1 2 1 1 Included 1 3 6 1 2 1 11 Included 1 3 6 1 6 3 10 2 1 Included 1 3 6 1 6 3 11 2 1 Included 1 3 6 1 6 3 15 1 1 Included CommunityView 1 Included 1 3 6 1 6 3 Excluded 1 3 6 1 6 3 1 Included Setting Range Parameter name Setting range oid SNMP OID included excl...

Страница 73: ...ps snmp authentication Disables the trap sending settings for an SNMP authentication failure Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None no snmp server enable traps snmp authentication Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 74: ...traps snmp coldstart Disables the trap sending settings for the SNMP coldstart Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None no snmp server enable traps snmp coldstart Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 75: ...ch the trap is sent when the link status changes Parameter Parameter name Description port Set the target port number Factory Default Setting Parameter name Factory default setting port None Setting Range Parameter name Setting range port Switch M24eGi 1 to 24 Switch M16eGi 1 to 16 Switch M8eGi 1 to 9 Multiple ports can be set Example 1 3 5 Note Parameter name Note port None ...

Страница 76: ...traps snmp coldstart Disables the trap sending settings for login failure Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None no snmp server enable traps login failure Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 77: ...able traps ddm Disables the trap sending settings for ddm Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None no snmp server enable traps ddm Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 78: ...community 2 public Read Only 192 168 1 200 4 Set the SNMP trap receiver settings as below trap receiver 1 SNMP v1 192 168 1 200 community public Fig 3 3 2 Example of executing the command to show the SNMP information M24eGi enable M24eGi configure M24eGi config snmp server agent M24eGi config snmp server community 1 private rw 192 168 1 200 M24eGi config snmp server community 2 public ro 192 168 1...

Страница 79: ...M24eGi enable M24eGi configure M24eGi config snmp server agent M24eGi config snmp server group test v3 M24eGi config snmp group read CommunityView M24eGi config snmp group notify CommunityView M24eGi config snmp group security level auth_nopriv M24eGi config snmp group exit M24eGi config snmp server user 1 test NOTICE Must set Auth if the user group is an auth_nopriv group Must set both Auth and P...

Страница 80: ... no shutdown Command to disable the port status M24eGi config if Shutdown Command to set the port mode M24eGi config if speed duplex auto 10 100 half 10 100 full Command to enable the flow control M24eGi config if flow control Command to disable the flow control M24eGi config if no flow control Command to set the port name M24eGi config if name string Command to enable the Auto MDI M24eGi config i...

Страница 81: ...sabled Enabled 6 1000T Enabled Down Auto Disabled Disabled 7 1000T Enabled Down Auto Disabled Disabled 8 1000T Enabled Down Auto Disabled Disabled 9 1000T Enabled Down Auto Disabled Disabled 10 1000T Enabled Down Auto Disabled Disabled 11 1000T Enabled Down Auto Disabled Disabled 12 1000T Enabled Down Auto Disabled Disabled 13 1000T Enabled Down Auto Disabled Disabled 14 1000T Enabled Down Auto Di...

Страница 82: ...e full or half Auto The auto negotiation function is enabled when the port link is down While the link is up the string enclosed in parentheses shows the communication speed and full duplex half duplex mode 1000F The port is in the 1000 Mbps full duplex mode 100 FDx 100F under the Auto mode The port is in the 100 Mbps full duplex mode 100 HDx 100H under the Auto mode The port is in the 100 Mbps ha...

Страница 83: ...83 9 Auto MDI Shows the Auto MDI MDI X setting Enabled The Auto MDI MDI X is enabled Disabled The Auto MDI MDI X is disabled ...

Страница 84: ...00T Down PORT_2 Disabled 3 1000T Down PORT_3 Disabled 4 1000T Down PORT_4 Disabled 5 1000T Down PORT_5 Disabled 6 1000T Down PORT_6 Disabled 7 1000T Down PORT_7 Disabled 8 1000T Down PORT_8 Disabled 9 1000T Down PORT_9 Disabled 10 1000T Down PORT_10 Disabled 11 1000T Down PORT_11 Disabled 12 1000T Down PORT_12 Disabled 13 1000T Down PORT_13 Disabled 14 1000T Down PORT_14 Disabled 15 1000T Down POR...

Страница 85: ...X The port type is SFP port 5 Link Shows the current link status Up The Link is established successfully Down The Link is not established 6 Port Name Shows the port name 7 EAP Pkt FW Shows the EAP packet forwarding setting Enabled The EAP packet forwarding is enabled Disabled The EAP packet forwarding is disabled ...

Страница 86: ...ault Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range interface name Switch M24eGi GigabitEthernet0 1 to GigabitEthernet0 24 Switch M16eGi GigabitEthernet0 1 to GigabitEthernet0 16 Switch M8eGi GigabitEthernet0 1 to GigabitEthernet0 9 The name can be abbreviated Example GigabitEthernet0 1 gi0 1 Note Parameter name Note None None ...

Страница 87: ...nterface setting information Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 88: ...rface name setting information Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 89: ...utdown Releases a port Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None no shutdown Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 90: ...the mode to 10 Mbps half duplex 10 full Set the mode to 10 Mbps full duplex 100 half Set the mode to 100 Mbps half duplex 100 full Set the mode to 100 Mbps full duplex Factory Default Setting Parameter name Factory default setting auto 10 100 half 10 100 full auto Setting Range Parameter name Setting range auto 10 100 half 10 100 full None Note Parameter name Note auto 10 100 half 10 100 full None...

Страница 91: ... flow control function Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None no frow control The flow control function is disabled Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 92: ...ault setting string Nothing is set Setting Range Parameter name Setting range string Up to 15 one byte characters Allowed characters alphanumeric character A Z a z 0 9 symbol _ white space Note Parameter name Note string To set a system name containing white spaces enclose the entire name with a pair of double quotation marks Example name port A ...

Страница 93: ...h M24eGi Ports 1 to 22 no mdix auto The Auto MDI MDI X function is disabled Ports 23 to 24 mdix auto The Auto MDI MDI X function is enabled Switch M16eGi Ports 1 to 14 no mdix auto The Auto MDI MDI X function is disabled Ports 15 to 16 mdix auto The Auto MDI MDI X function is enabled Switch M8eGi Ports 1 to 7 no mdix auto The Auto MDI MDI X function is disabled Ports 8 mdix auto The Auto MDI MDI X...

Страница 94: ...94 Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 95: ...iption None None Factory Default Setting Parameter name Factory default setting None no jumbo Jumbo frame is disabled Setting Range Parameter name Setting range None None Note Parameter name Note None When jumbo frame is enabled the maximum frame size is set at 9220 bytes including a VLAN tag ...

Страница 96: ...AP frame forwarding Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None no eap forward EAP frame forwarding is disabled Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 97: ...Example 3 Overview Enable the Auto MDI MDI X function for Ports 5 to 8 1 Move to the interface configuration mode for Port 5 to 8 2 Set auto to the Auto MDI MDI X function for Ports 5 to 8 Fig 3 4 5 Example of configuring the Auto MDI MDI X M24eGi enable M24eGi configure M24eGi config interface gi0 1 M24eGi config if shutdown M24eGi config if exit M24eGi config M24eGi 1 2 M24eGi enable M24eGi conf...

Страница 98: ...ub in Global configuration mode Confirm the configuration information by executing the show terminal length command in Privileged mode Command to show the number of lines on a screen M24eGi show terminal length Command to set the number of lines on a screen M24eGi config terminal length LENGTH ...

Страница 99: ...on a screen is shown below Fig 3 5 1 Example of executing the command to show the number of lines on a screen 1 Terminal Length Shows the number of lines displayed on a screen none is shown if this value is set to 0 M24eGi enable M24eGi show terminal length Terminal Length 24 rows M24eGi 1 ...

Страница 100: ...er of lines displayed on a screen Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 101: ...n LENGTH Set the number of lines displayed on a screen Assigning the value 0 sets no limit on the number of lines displayed on a screen Factory Default Setting Parameter name Factory default setting LENGTH 24 Setting Range Parameter name Setting range LENGTH 0 or 24 to 512 Note Parameter name Note LENGTH None ...

Страница 102: ...es displayed on a screen to unlimited 1 Set no limit on the number of lines displayed on a screen Fig 3 5 2 Example of configuring the number of lines displayed on a screen M24eGi enable M24eGi conf M24eGi config terminal length 0 M24eGi config exit M24eGi 1 ...

Страница 103: ...ub via console in Global configuration mode Confirm the configuration information by executing the show console command in Privileged mode Command to show the console configuration M24eGi show console Command to set the console timeout M24eGi config console inactivity timer minutes ...

Страница 104: ...g the command to show the console configuration 1 Console UI Idle Timeout Shows the maximum inactivity time to wait for a user input in a console session Upon expiration the session is automatically terminated If the auto disconnection is disabled no timeout is shown M24eGi enable M24eGi show console Console UI Idle Timeout 5 minutes M24eGi 1 ...

Страница 105: ...a console session Upon expiration the session is automatically terminated Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 106: ...e Description minutes Set the maximum inactivity time in minutes to wait for a user input in a console session Upon expiration the session is automatically terminated Factory Default Setting Parameter name Factory default setting minutes 5 minutes Setting Range Parameter name Setting range minutes 0 to 60 minutes Entering 0 disables the automatic disconnection Note Parameter name Note minutes None...

Страница 107: ...isconnection of a console session 1 Disable the automatic disconnection for the console inactivity time Fig 3 5 1 2 Example of configuring the automatic disconnection time for inactivity M24eGi enable M24eGi conf M24eGi config console inactivity timer 0 M24eGi config exit M24eGi 1 ...

Страница 108: ...erver enable Command to disable the telnet server M24eGi config no telnet server enable Command to set the telnet server timeout M24eGi config telnet server inactivity timer minutes Command to enable the telnet access limitation M24eGi config telnet server ipv6 access limitation enable Command to disable the telnet access limitation M24eGi config no telnet server ipv6 access limitation enable Comm...

Страница 109: ... enabled Disabled The telnet server is disabled 3 Telnet Access Limitation Shows the access limitation settings from telnet clients Enabled The access limitation from telnet clients is enabled Disabled The access limitation from telnet clients is disabled M24eGi enable M24eGi show telnet server Telnet UI Idle Timeout 5 minutes Telnet Server Enabled Telnet Access Limitation Disabled No IP Address S...

Страница 110: ...tion Shows the ipv6 access limitation settings from telnet clients Enabled The ipv6 access limitation from telnet clients is enabled Disabled The ipv6 access limitation from telnet clients is disabled 8 No Shows the entry number assigned to the access limited ipv6 address of a telnet client 9 IPv6 Address Shows the IPv6 address or the IPv6 address range to allow access from telnet clients If no IP...

Страница 111: ... server configuration information Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 112: ...sables the telnet server Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None telnet server enable The telnet server is disabled Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 113: ...d Parameter Parameter name Description minutes Set the maximum inactivity time in minutes to wait for a user input in a telnet client session Upon expiration the session is automatically terminated Factory Default Setting Parameter name Factory default setting minutes 5 minutes Setting Range Parameter name Setting range minutes 1 to 60 minutes Note Parameter name Note minutes None ...

Страница 114: ...ameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None no telnet server access limitation enable The access limitation from telnet clients is disabled no ipv6 telnet server access limitation enable The ipv6 access limitation from telnet clients is disabled Setting Range Parameter name Setting range None None Note Parameter name Note None Non...

Страница 115: ...ess prefixlen Set a prefix length to allow access from the IPv6 address range Factory Default Setting Parameter name Factory default setting entry None ip address None mask None ipv6 address None prefixlen None Setting Range Parameter name Setting range entry Enter an entry number from 1 to 5 ip address 1 0 0 1 to 223 255 254 254 mask 128 0 0 0 to 255 255 255 255 One bits and zero bits must be con...

Страница 116: ... the sessions are allowed only from specific ipv6 network addresses 2001 1 1 to 2001 1 FFFF 1 Enable the ipv6 access limitation from telnet 2 Add the network address 2001 1 0 prefix length 112 as a source address for telnet connections to Entry No 1 Fig 3 5 2 2 Example of configuring the ipv6 telnet access limitation M24eGi enable M24eGi configure M24eGi config telnet server access limitation enab...

Страница 117: ...ssh Command to enable the SSH server M24eGi config crypto key generate rsa Command to delete the SSH server M24eGi config crypto key zeroize rsa Command to set the SSH server timeout M24eGi config ip ssh time out minutes Command to set the SSH server authentication timeout M24eGi config ip ssh authentication timeout seconds Command to set the number of SSH server authentication retries M24eGi conf...

Страница 118: ... the session is automatically terminated 2 SSH Auth Idle Timeout Shows the response timeout time for SSH authentication 3 SSH Auth Retries Time Shows the maximum number of SSH authentication retries 4 SSH Server Shows whether or not the access via SSH is allowed 5 SSH Server Key Shows the status of the SSH server key M24eGi enable M24eGi show ip ssh SSH UI Idle Timeout 5 Min SSH Auth Idle Timeout ...

Страница 119: ...er configuration information Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 120: ... name Description None None Factory Default Setting Parameter name Factory default setting None crypto key zeroize rsa The access via SSH is disabled Setting Range Parameter name Setting range None None Note Parameter name Note None Up to two users can access the Switching Hub concurrently via SSH For the SSH login procedure follow the operation procedure for each SSH client ...

Страница 121: ...ted Parameter Parameter name Description minutes Set the maximum inactivity time in minutes to wait for a user input Upon expiration the session is automatically terminated Factory Default Setting Parameter name Factory default setting minutes 5 minutes Setting Range Parameter name Setting range minutes 1 to 60 minutes Note Parameter name Note minutes None ...

Страница 122: ...Parameter Parameter name Description seconds Set the response timeout time in seconds for SSH authentication Factory Default Setting Parameter name Factory default setting seconds 120 seconds Setting Range Parameter name Setting range seconds 1 to 120 seconds Note Parameter name Note seconds None ...

Страница 123: ...r Parameter name Description retries Set the maximum number of SSH authentication retries The first try is counted as a retry Factory Default Setting Parameter name Factory default setting retries 5 times Setting Range Parameter name Setting range retries 0 to 5 times Note Parameter name Note retries None ...

Страница 124: ...ration the session is automatically terminated 1 Enable the access via SSH 2 Set the timeout time to 40 seconds If no input is made before it expires the session is automatically terminated Fig 3 5 3 2 Example of the SSH server configuration M24eGi enable M24eGi conf M24eGi config crypto key generate rsa M24eGi config ip ssh time out 40 M24eGi config exit M24eGi 1 2 ...

Страница 125: ...onfirm the configuration information by executing the show ip http server command in Privileged mode Command to show the Web configuration M24eGi show ip http server Command to enable the Web server M24eGi config ip http server Command to disable the Web server M24eGi config no ip http server ...

Страница 126: ...mmand to show the Web configuration is shown below Fig 3 5 4 1 Example of executing the command to show the Web configuration 1 Web Server Shows whether or not the access via Web is allowed M24eGi enable M24eGi show ip http server Web Server Enabled M24eGi 1 ...

Страница 127: ...server configuration information Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 128: ...rver Disables the access via Web Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None The access via Web is disabled Setting Range Parameter name Setting range None None Note Parameter name Note None ...

Страница 129: ...ration Example Overview Enable the access via Web 1 Enable the access via Web Fig 3 5 4 2 Example of the Web server configuration M24eGi enable M24eGi conf M24eGi config ip http server M24eGi config exit M24eGi 1 ...

Страница 130: ...how radius server Command to configure the RADIUS server access settings M24eGi config radius server host index ip ip address ipv6 ipv6 address timeout sec s retransmit retries key string encrypt encrypted key encrypted string Command to set the NAS ID M24eGi config dot1x nasid string Command to delete the NAS ID M24eGi config no dot1x nasid Command to show the login method configuration M24eGi sh...

Страница 131: ...ation order to RADIUS server The authentication is carried out starting from Index No 1 If the communications with the RADIUS server fails then the authentication is carried out for Index No 2 and so on in ascending order 3 Server IP address Shows the IP address of RADIUS server M24eGi show radius server NAS ID Nas1 Index Server IP address Shared Secret Response Time Max Retransmission 1 192 168 1...

Страница 132: ...on key 5 Response Time Shows the maximum response time for authentication request to RADIUS server 6 Max Retransmission Shows the maximum number of retransmissions of authentication request to RADIUS server 7 login method 1 Shows the first login method to authenticate using the username and password 8 login method 2 Shows the second login method to authenticate using the username and password ...

Страница 133: ... server configuration information Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 134: ...ions of authentication request to RADIUS server string Set the common key Shared Secret that is used in authentication encrypted string Set the encrypted common key Shared Secret that is used in authentication Factory Default Setting Parameter name Factory default setting index None ip address 0 0 0 0 ipv6 address 0 0 sec s 10 retries 3 string None encrypted string None Setting Range Parameter nam...

Страница 135: ... this option The entered string will be encrypted and will be saved into configuration file encrypt key When uses this option The entered string will not be encrypted and will be saved into configuration file It needs to enter the encrypted string ...

Страница 136: ...ier Parameter Parameter name Description string Set a new authentication ID Factory Default Setting Parameter name Factory default setting string Nas1 Setting Range Parameter name Setting range string Up to 16 one byte characters Note Parameter name Note string None ...

Страница 137: ...uthenticate using the username and password Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 138: ...device is carried out by using the username and password stored in the device RADIUS Login to the device is carried out by using RADIUS server authentication None Login Method 2 is not used auth fail action Set the next action after the login method 1 authentication is failed method2 Use the login method 2 authentication stop Stop the authentication Factory Default Setting Parameter name Factory d...

Страница 139: ...rst login method to a RADIUS server for authentication using the username and password 3 Set the second login method to the information stored locally in this Switching Hub for authentication using the username and password Fig 3 5 5 3 Example of the RADIUS server access configuration M24eGi enable M24eGi conf M24eGi config radius server host 1 ip 192 168 1 200 key admin M24eGi config login method...

Страница 140: ...nformation by executing the show ip setup interface command in Privileged mode Command to show the easy IP address setup function M24eGi show ip setup interface Command to enable the easy IP address setup function configuration M24eGi config ip setup interface Command to disable the easy IP address setup function configuration M24eGi config no ip setup interface ...

Страница 141: ...ple of executing the command to show the easy IP address setup function 1 IP Setup Interface Shows the easy IP address setup function configuration Enabled The easy IP address setup function is enabled Disabled The easy IP address setup function is disabled M24eGi enable M24eGi show ip setup interface IP Setup Interface Enabled M24eGi 1 ...

Страница 142: ...P address setup function configuration Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 143: ...e easy IP address setup function Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None ip setup interface The easy IP address setup function is enabled Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 144: ...e easy IP address setup function 1 Enable the easy IP address setup function Fig 3 5 6 2 Example of configuration of the easy IP address setup function M24eGi enable M24eGi configure M24eGi config no ip setup interface M24eGi config exit M24eGi 1 ...

Страница 145: ...nfiguration M24eGi config syslog server disable Command to enable the syslog transmission configuration M24eGi config syslog server enable index Command to disable the syslog transmission configuration M24eGi config syslog server disable index Command to set the facility configuration M24eGi config syslog facility index facilities Command to delete the syslog server configuration M24eGi config cle...

Страница 146: ...ion Shows the syslog transmission function configuration Enabled The syslog transmission function is enabled Disabled The syslog transmission is disabled M24eGi enable M24eGi show syslog conf Syslog Transmission Disabled 1 Syslog Server List 2 No Status Ip Address Facility Include SysName IP 1 Disabled 0 0 0 0 Facility0 2 Disabled 0 0 0 0 Facility0 No Status IPv6 Address 1 Disabled 1 1 2 Disabled ...

Страница 147: ...P address setup function configuration Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 148: ...e easy IP address setup function Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None ip setup interface The easy IP address setup function is enabled Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 149: ...e easy IP address setup function 1 Enable the easy IP address setup function Fig 3 5 7 2 Example of configuration of the easy IP address setup function M24eGi enable M24eGi configure M24eGi config no ip setup interface M24eGi config exit M24eGi 1 ...

Страница 150: ...w mac address table static Command to set the aging time M24eGi config mac address table aging time aging time Command to register the static MAC address entry M24eGi config mac address table static MAC addr interface name vlan VLAN ID Command to delete the static MAC address entry M24eGi config no mac address table static MAC addr vlan VLAN ID Command to enable MAC address auto learning M24eGi co...

Страница 151: ...nabled Disabled MAC address auto learning is disabled M24eGi enable M24eGi show mac learning Interface MAC Learning MAC Learning Limit gi0 1 Auto Disabled gi0 2 Auto Disabled gi0 3 Auto Disabled gi0 4 Auto Disabled gi0 5 Auto Disabled gi0 6 Auto Disabled gi0 7 Auto Disabled gi0 8 Auto Disabled gi0 9 Auto Disabled gi0 10 Auto Disabled gi0 11 Auto Disabled gi0 12 Auto Disabled gi0 13 Auto Disabled g...

Страница 152: ...er of auto learned MAC addresses Command Entry Example An example of executing the command to show the aging time is shown below Fig 3 6 2 Example of executing the command to show the aging time 1 MAC address table aging time Shows the aging time which is the time until the learned entries in the MAC address table are deleted M24eGi enable M24eGi show mac address table aging time MAC address table...

Страница 153: ... the MAC address table 2 Address Type Shows the MAC address entry type Dynamic Dynamically learned MAC address entry 3 VLAN Shows the VLAN ID that is learning the MAC address entry 4 Port Shows the interface name gi0 1 Refers to Gigabit Ethernet Port 1 The number after gi0 indicates the port number M24eGi enable M24eGi show mac address table mac MAC Address Address Type VLAN Port xx xx xx xx xx xx...

Страница 154: ...he MAC address table 2 Address Type Shows the MAC address entry type Static Statically registered MAC address entry 3 VLAN Shows the VLAN ID that is learning the MAC address entry 4 Port Shows the interface name gi0 1 Refers to Gigabit Ethernet Port 1 The number after gi0 indicates the port number M24eGi enable M24eGi show mac address table static MAC Address Address Type VLAN Port xx xx xx xx xx ...

Страница 155: ... time show mac address table mac Shows dynamically learned MAC address entries show mac address table static Shows statically registered MAC address entries Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 156: ...deleted Parameter Parameter name Description aging time Set the time in seconds between frame receiving and dynamic entry deletion Factory Default Setting Parameter name Factory default setting aging time 300 seconds Setting Range Parameter name Setting range aging time 10 to 1000000 seconds Note Parameter name Note aging time None ...

Страница 157: ...e Set the interface name of the target port VLAN ID Set the target VLAN ID Factory Default Setting Parameter name Factory default setting MAC addr None interface name None VLAN ID None Setting Range Parameter name Setting range MAC addr 00 00 00 00 00 01 to FF FF FF FF FF FE interface name Switch M24eGi GigabitEthernet0 1 to GigabitEthernet0 24 Switch M16eGi GigabitEthernet0 1 to GigabitEthernet0 ...

Страница 158: ...158 Note Parameter name Note MAC addr None interface name None VLAN ID Set an existing VLAN ID ...

Страница 159: ...t Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None mac learning Setting Range Parameter name Setting range None None Note Parameter name Note None If MAC address auto learning is disabled communication cannot be established unless a MAC address is registered statically ...

Страница 160: ...rning limit Deletes the limit of the number of auto learned MAC addresses for each port Parameter Parameter name Description limit Set the limit of the number of auto learned MAC addresses for each port Factory Default Setting Parameter name Factory default setting limit None Setting Range Parameter name Setting range limit 1 to 256 Note Parameter name Note limit 1 To use this function MAC address...

Страница 161: ... Example of static MAC address entry Configuration Example 3 Overview Set the limit of the number of auto learned MAC addresses for Port 1 to 1 1 Set the limit of the number of auto learned MAC addresses for Port 1 to 1 Fig 3 6 7 Example of setting the limit of the number of auto learned MAC M24eGi enable M24eGi configure M24eGi config mac address table static 00 00 00 00 00 01 gi0 1 vlan 1 M24eGi...

Страница 162: ...162 addresses ...

Страница 163: ...and to enable SNTP M24eGi config sntp enable Command to disable SNTP M24eGi config sntp disable Command to set the SNTP server IP address M24eGi config sntp server ip address Command to set the interval of SNTP time acquisition M24eGi config sntp polling interval min Command to enable SNTP daylight saving M24eGi config sntp daylight saving Command to disable SNTP daylight saving M24eGi config no s...

Страница 164: ... SNTP function is disabled 3 SNTP Server Shows the SNTP server address configuration 4 SNTP Polling Interval Shows the time acquisition interval 5 Time Zone Shows the time zone configuration 6 Daylight Saving Shows the daylight saving configuration Enabled Daylight saving is enabled Disabled Daylight saving is disabled M24eGi enable M24eGi show sntp Clock Time Wed 21 Jul 2010 12 00 00 SNTP Enabled...

Страница 165: ...ime and SNTP configuration Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 166: ...MM DD format time Set the time in HH MM SS format Factory Default Setting Parameter name Factory default setting date 1970 01 01 time 00 00 00 Setting Range Parameter name Setting range date YYYY 1970 to 2037 MM 1 to 12 DD 1 to 31 time HH 00 to 23 MM 00 to 59 SS 00 to 59 Note Parameter name Note date None time None ...

Страница 167: ...p disable Disables the SNTP function Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None disable Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 168: ... Set an IP address of SNTP server Factory Default Setting Parameter name Factory default setting ip address 0 0 0 0 Setting Range Parameter name Setting range ip address 0 0 0 0 to 223 254 254 254 Note Parameter name Note ip address None Note If you set SNTP server to 0 0 0 0 SNTP is automatically disabled ...

Страница 169: ...ameter Parameter name Description min Set the time acquisition interval The unit is minutes Factory Default Setting Parameter name Factory default setting min 1440 minutes Setting Range Parameter name Setting range min 1 to 1440 minutes Note Parameter name Note min None ...

Страница 170: ...ight saving Disables daylight saving Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None no sntp daylight saving Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 171: ...e Description location Set the time zone None The time zone list is displayed Factory Default Setting Parameter name Factory default setting location 51 Osaka Sapporo Tokyo Setting Range Parameter name Setting range location 1 to 63 Note Parameter name Note location None ...

Страница 172: ...e Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None Note SNTP function must be enabled to execute the sntp update command ...

Страница 173: ... SNTP server from which time is acquired to 192 168 1 1 2 Set the time acquisition interval to 60 minutes 3 Enable the SNTP function Fig 3 7 3 Example of the SNTP server configuration Note If you set SNTP server to 0 0 0 0 SNTP is automatically disabled M24eGi enable M24eGi configure M24eGi config sntp clocktime 2010 7 21 12 00 00 M24eGi config exit M24eGi M24eGi enable M24eGi configure M24eGi con...

Страница 174: ...xecuting the show arp sort ip command in Privileged mode Command to show the ARP table information M24eGi show arp sort ip Command to set the ARP aging time M24eGi config arp timeout timeout ARP static registration command M24eGi config arp ip address MAC address ARP static deletion command M24eGi config no arp ip address ...

Страница 175: ...IP Address Lists learned IP addresses in the ARP table 2 HWaddress Lists learned MAC addresses in the ARP table 3 Type Shows the learning type for the ARP table Dynamic Auto learned address information Static Information of an address registered according to the configuration M24eGi enable M24eGi show arp sort ip IP Address HWaddress Type 192 168 0 100 00 00 00 00 00 01 Static M24eGi 1 2 3 ...

Страница 176: ...P table registration status Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 177: ...arameter name Description timeout Set the timeout for the ARP table in seconds Factory Default Setting Parameter name Factory default setting timeout 7200 seconds Setting Range Parameter name Setting range timeout 30 to 86400 seconds Note Parameter name Note timeout None ...

Страница 178: ...able MAC address Set the MAC address to be registered in the ARP table Factory Default Setting Parameter name Factory default setting ip address None MAC address None Setting Range Parameter name Setting range ip address 1 0 0 0 to 223 255 255 255 MAC address Unicast address Note Parameter name Note ip address None MAC address None Note Up to 256 static and dynamic entries in total can be register...

Страница 179: ... 2 Overview Manually register addresses in the ARP table 1 Manually register addresses IP 192 168 0 100 MAC 00 00 00 00 00 01 in the ARP table Fig 3 8 3 Example of manual registration in the ARP table 1 M24eGi enable M24eGi configure M24eGi config arp 192 168 0 100 00 00 00 00 00 01 M24eGi config exit M24eGi 1 M24eGi enable M24eGi configure M24eGi config arp timeout 14400 M24eGi config exit M24eGi...

Страница 180: ...ese parameters VLAN ID VLAN ID is a VLAN identifier placed on each frame in processing tagged frames As for an untagged frame ports are divided into groups by this ID and the forwarding destination of the frame is determined by referring to this ID Multiple VLANs can be assigned to each port PVID Port VLAN ID Only one PVID can be set to each port When an untagged frame is received this ID determin...

Страница 181: ...onfigure VLAN M24eGi config interface vlan vlan id Command to set the VLAN name M24eGi config if name name Command to delete the VLAN name M24eGi config if no name Command to set the VLAN members M24eGi config if member port list Command to set the management VLAN M24eGi config if management Command to delete the management VLAN M24eGi config if no management Command to set the PVID M24eGi config ...

Страница 182: ...rently registered in this Switching Hub 3 Status Shows the VLAN ID status in two lines static Indicates that the VLAN ID has been manually registered in this Switching Hub Only the data for VLAN ID 1 is created at the factory management Indicates that the VLAN is a management VLAN that responds to Ping Telnet and other remote access The Command Entry Example shows that only VLAN 1 belongs to the M...

Страница 183: ...183 management VLAN and VLAN 10 and 20 do not ...

Страница 184: ...ith U T Tagged ports are indicated with T Ports that do not belong to the VLAN ID are indicated with The following shows the port status of M24eGi VLAN ID 10 in the Command Entry Example VLAN ID Status Name Port No 1234 5678 9012 3456 7890 1234 10 static VLAN10 UUUU TT Port No VLAN ID 10 member Tagged Untagged 1 Yes Untagged 2 Yes Untagged 3 Yes Untagged 4 Yes Untagged 5 No 6 No 7 No 8 No 9 No 10 ...

Страница 185: ...LAN to be displayed all All VLANs are displayed vlan id list Only specified VLANs are displayed Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range vlan id list 1 to 4094 Multiple VLANs can be specified Example 1 3 5 Note Parameter name Note vlan id list None ...

Страница 186: ...id Execute the command in vlan vlan id form like vlan10 No spaces are allowed between vlan and vlan id Note When creating a new VLAN PVID after mentioned is not changed in conjunction with this new creation Make sure to confirm the configuration When you wish to delete a VLAN you cannot delete it if the VLAN ID of the VLAN to be deleted still remains as a PVID Delete the VLAN after changing the PV...

Страница 187: ...ult Setting Parameter name Factory default setting name None Setting Range Parameter name Setting range name Up to 32 one byte characters Allowed characters alphanumeric character A Z a z 0 9 symbol _ white space Note Parameter name Note name To set a VLAN name containing white spaces enclose it with a pair of double quotation marks Example name VLAN 1 ...

Страница 188: ...LAN 1 to 24 Switch M16eGi VLAN1 default VLAN 1 to 16 Switch M8eGi VLAN1 default VLAN 1 to 9 Other VLANs None Setting Range Parameter name Setting range port list Switch M24eGi 1 to 24 Switch M16eGi 1 to 16 Switch M8eGi 1 to 9 Multiple ports can be specified Example 1 3 5 Note Parameter name Note port list If you execute the command without specifying the parameter all ports belonging to the VLAN w...

Страница 189: ...f VLAN as a management VLAN Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None VLAN 1 management Other than VLAN 1 no management Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 190: ...the VLAN identified by the PVID This command is executed in interface configuration mode of each port Parameter Parameter name Description vlan id Set the PVID Port VLAN ID Only one PVID can be set for each port Factory Default Setting Parameter name Factory default setting vlan id 1 Setting Range Parameter name Setting range vlan id 1 to 4094 Note Parameter name Note vlan id None ...

Страница 191: ...rameter Parameter name Description all tag only Set the type of received frames all Receives all frames tag only Receives only VLAN tagged frames Factory Default Setting Parameter name Factory default setting all tag only all Setting Range Parameter name Setting range all tag only Either all or tag only Note Parameter name Note all tag only None ...

Страница 192: ...5 Move to the global configuration mode 6 Move to the interface configuration mode for Ports 1 and 2 7 Set PVID for Ports 1 and 2 to 10 Since the VLAN ID and PVID are identical the port is untagged Fig 4 1 2 Example of the VLAN creation configuration Since PVID of Port 24 is 1 the port is tagged M24eGi enable M24eGi configure M24eGi config interface vlan10 M24eGi config if member 1 2 24 M24eGi con...

Страница 193: ...VID 6 Confirm that VLAN ID 10 has been deleted Fig 4 1 3 Example of the VLAN deletion configuration M24eGi en M24eGi configure M24eGi config interface vlan10 M24eGi config if member M24eGi config if exit M24eGi config interface gi0 1 2 M24eGi config if pvid 1 M24eGi config if exit M24eGi config exit M24eGi 1 M24eGi show vlan 10 NOTE U Untagged port member T Tagged port member Not a port member VLA...

Страница 194: ...guration information by executing the show internet mansion command in Privileged mode Command to show the Internet mansion configuration M24eGi show internet mansion Command to configure the Internet mansion M24eGi config internet mansion port list Command to disable the Internet mansion configuration M24eGi config no internet mansion ...

Страница 195: ...on function status Enabled or Disabled Enabled The Internet mansion function is enabled Disabled The Internet mansion function is disabled 2 Promiscuous Port Members Shows the uplink port number set during configuration of the Internet mansion function 3 Internet Mansion Shows the downlink port number M24eGi enable M24eGi show internet mansion Internet Mansion Enabled Promiscuous Port Members gi0 ...

Страница 196: ...Internet mansion configuration Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 197: ...ated port is used as an uplink port Other ports can be used for downlink communication only and downlink ports cannot communicate with one another Therefore it becomes possible to ensure security between each resident Factory Default Setting Parameter name Factory default setting port list None The Internet mansion function is disabled Setting Range Parameter name Setting range port list Switch M2...

Страница 198: ... conditions as follows Please confirm the conditions before use 1 Combined usage with the link aggregation function is not possible 2 Only the uplink port belongs to the management VLAN Note When Internet mansion mode is enabled all VLAN configurations are overwritten ...

Страница 199: ...s uplink ports 2 Enter y to enable the Internet mansion function All VLAN configuration and PVID of each port are reset Fig 4 1 1 2 Example of configuration of the Internet mansion function 1 2 M24eGi enable M24eGi configure M24eGi config internet mansion 23 24 This command will remove all VLANs other than VLAN1 and the PVID of all ports will be VLAN1 Y N y M24eGi config exit M24eGi ...

Страница 200: ...umber to a port list of access control not a logical port created in link aggregation For details refer to 4 4 The maximum number of ports and groups is as follows Product name Max number of ports group Max number of groups Switch M24eGi Switch M16eGi 8 8 Note Depending on number of ports in a group or the traffic condition traffic may not be assigned uniformly to all the ports Note If you shutdow...

Страница 201: ...link aggregation configuration M24eGi show aggregation link group Aggregation link group ID Command to configure the link aggregation M24eGi config aggregation link group Aggregation link group ID port list Command to delete the link aggregation configuration M24eGi config no aggregation link group Aggregation link group ID ...

Страница 202: ...dst L4 port Traffic distribution is performed based on the destination and the source MAC address IP address and L4 port value of the transmitted frame 4 Admin Ports Shows the list of ports set in the aggregation group 5 Oper Ports Shows the list of ports currently belonging to the aggregation group Shows none if none of the Admin Ports are linked up M24eGi enable M24eGi show aggregation link grou...

Страница 203: ...oup ID Specify the group number of the link aggregation If you don t specify it all groups are displayed Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range Aggregation link group ID 1 to 8 A range can be specified with a hyphen None All groups are displayed Note Parameter name Note None None ...

Страница 204: ...rt list Specify ports belonging to the link aggregation Factory Default Setting Parameter name Factory default setting Aggregation link group ID None port list None Setting Range Parameter name Setting range Aggregation link group ID Switch M8eGi 1 to 4 Other 1 to 8 Up to eight groups can be set for each switch port list Switch M24eGi 1 to 24 Switch M16eGi 1 to 16 Switch M8eGi 1 to 9 Up to eight p...

Страница 205: ...ration Example Overview Set Ports 1 to 8 in an aggregation link 1 Create an aggregation link as Group 1 including Ports 1 to 8 Fig 4 2 2 Example of the link aggregation configuration M24eGi enable M24eGi configure M24eGi config aggregation link group 1 1 8 M24eGi config exit M24eGi 1 ...

Страница 206: ...onfiguration mode Confirm the configuration information by executing the show monitor command in Privileged mode Command to show the monitoring configuration M24eGi show monitor Command to configure the port monitoring M24eGi config if port monitor monitored port direction rx tx both ...

Страница 207: ...monitoring function is disabled 2 Monitoring direction Indicates which packet should be monitored the transmit packet or the receive packet Tx The transmit packet is monitored Rx The receive packet is monitored Both Both of the transmit and receive packet are monitored 3 Monitoring port Shows the port number of a port to monitor other port s packets 4 Monitored port Shows the port number of a port...

Страница 208: ...toring function configuration Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 209: ...mit packet or the receive packet Tx The transmit packet is monitored Rx The receive packet is monitored Both Both of the transmit and receive packet are monitored Factory Default Setting Parameter name Factory default setting monitored port None rx tx both None Setting Range Parameter name Setting range monitored port Switch M24eGi 1 to 24 Switch M16eGi 1 to 16 Switch M8eGi 1 to 9 Multiple ports c...

Страница 210: ...guration Configuration Example 2 Overview Disable the port monitoring function enabled as Configuration Example 1 shows 1 Move to the interface configuration mode for Port 1 2 Disable packet monitoring Fig 4 3 3 Example of the configuration for disabling port monitoring M16eG enable M16eG configure M16eG config interface GigabitEthernet0 1 M16eG config if port monitor 2 5 direction both M16eG conf...

Страница 211: ... to show the policy configuration M24eGi show AccessControl policy all policy number Command to show the policy sequence configuration M24eGi show AccessControl policy sequence port port num sort policy index sequence Command to configure the classifier M24eGi Config AccessControl classifier id src mac MAC dst mac MAC src net ip mask dst net ip mask src port layer4 port list dst port layer4 port l...

Страница 212: ...t index port num Command to delete the port list M24eGi Config no AccessControl portlist port list index Command to configure the policy M24eGi Config AccessControl policy index portlist port list index classifier c index policy sequence value inprofile i index outprofile o index Command to enable the policy M24eGi Config AccessControl policy index enable Command to disable the policy M24eGi Confi...

Страница 213: ...Flag Shows whether or not TCP SYN flag should be included in the target 7 ICMP Type Shows whether or not ICMP type should be included in the target 8 Source MAC Address Shows whether or not the source MAC address should be included in the target M24eGi enable M24eGi show AccessControl classifier all Classifier Index 1 VLAN ID Ignore 802 1p Priority Ignore DSCP Ignore Protocol Ignore TCP SYN Flag I...

Страница 214: ...urce IP address should be included in the target 13 Source IP Mask Length Shows whether or not the mask length of the source IP address should be included in the target 14 Destination IP Address Shows whether or not the destination IP address should be included in the target 15 Destination IP Mask Length Shows whether or not the mask length of the destination IP address should be included in the t...

Страница 215: ...rks the DSCP value 5 Policied Precedence Marks the precedence value 6 Policied CoS Marks the CoS value 7 Total Entries Shows the number of out profile entries created 8 Index Shows the out profile index number M24eGi enable M24eGi show AccessControl inprofile In Profile Action Total Entries 1 Index Deny Permit Policied DSCP Policied Precedence Policied CoS 1 Permit Ignore Ignore Ignore M24eGi show...

Страница 216: ...st Size KB Shows the traffic burst size that can be transmitted exceeding the committed rate 11 Deny Permit Shows whether or not communications are denied or permitted Deny Permits communications Permit Denies communications 12 Policied DSCP Marks the DSCP value ...

Страница 217: ...ndex Port List 1 3 6 9 M24eGi show AccessControl policy 1 Policy Index 1 Status Enabled Classifier Index 1 Source MAC Addr Mask Ignore Destination MAC Addr Mask Ignore 802 1P Priority Ignore VLAN ID Ignore Source IP Addr Mask Ignore Destination IP Addr Mask Ignore DSCP Ignore Protocol Ignore Source L4 Port Ignore Destination L4 Port Ignore TCP SYN Flag Ignore ICMP Type Ignore Policy Sequence 1 In ...

Страница 218: ... the destination MAC address and the mask length 9 802 1P Priority Shows the IEEE 802 1p priority 10 VLAN ID Shows the VLAN ID 11 Source IP Addr Mask Shows the destination IP address and the mask length 12 Destination IP Addr Mask Shows the source IP address and the mask length 13 DSCP Shows the DSCP value 14 Protocol Shows the protocol number 15 Source L4 Port Shows the source port number 16 Dest...

Страница 219: ...e 19 Policy Sequence Shows the policy sequence 20 In Profile Action Shows details of the in profile action used in the policy 21 Out Profile Action Shows details of the out profile action used in the policy 22 Port List Action Shows details of the port list used in the policy ...

Страница 220: ...r number Specify the classifier to be displayed all The configuration of all classifiers is displayed classifier number The configuration of the classifier with the specified index number is displayed Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range classifier number 1 to 65535 Note Parameter name Note None None ...

Страница 221: ...file configuration used for the access control function Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 222: ...ofile configuration used for the access control function Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 223: ...ist configuration used for the access control function Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 224: ...ber Specify a policy index number to be displayed all The configuration of all policies is displayed policy number The configuration of the policy with the specified policy number is displayed Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range policy number 1 to 65535 Note Parameter name Note None None ...

Страница 225: ... number policy index sequence Specify a policy sequence display mode policy index The sequence is in order of the policy number sequence The sequence is in order of the sequence number Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range port num Switch M24eGi 1 to 24 Switch M16eGi 1 to 16 Switch M8eGi 1 to 9 Only a single port can be ...

Страница 226: ...n MAC address src net ip mask Specify the source IP network and mask dst net ip mask Specify the destination IP network and mask src port layer4 port list Specify the TCP UDP source port number dst port layer4 port list Specify the TCP UDP destination port number vlan id vid Specify the VLAN ID dot1p priority priority Specify the IEEE 802 1p priority dscp value Specify the DSCP value protocol pro ...

Страница 227: ... and 192 168 1 21 are specified 192 168 2 1 25 127 units 192 168 2 1 to 192 168 2 127 are specified 192 168 2 1 24 254 units 192 168 2 1 to 192 168 2 254 are specified layer4 port list 0 to 65535 You can set a range of port numbers Example 137 139 vid 1 to 4094 priority 0 to 7 value 0 to 63 pro num 1 to 255 Example 1 ICMP 2 IGMP 6 TCP 17 UDP 46 RSVP icmptype 0 to 18 Example 0 Echo Reply 3 Destinat...

Страница 228: ...le index number deny permit dscp dscp value precedence p value cos c value Specify whether packets are denied or permitted deny Packets are denied permit Packets are permitted You can select the value type from the following for marking at the permission DSCP value ToS precedence value CoS value Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name S...

Страница 229: ... volume Specify the burst size with the burst size number deny permit dscp value Specify whether packets are denied or permitted deny Packets are denied permit Packets are permitted You can select the value type from the following for marking at the permission DSCP value Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range index 1 to 6...

Страница 230: ...er Parameter name Description port list index Specify the port list index number port num Specify the Switching Hub port number Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range port list index 1 to 65535 port num Switch M24eGi 1 to 24 Switch M16eGi 1 to 16 Switch M8eGi 1 to 9 Multiple ports can be specified Example 1 3 5 Note Param...

Страница 231: ...er port list index Specify the port list index number c index Specify the classifier index number value Specify the policy sequence value i index Specify the in profile index number outprofile o index Specify the out profile index number Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range index 1 to 65535 port list index 1 to 65535 c ...

Страница 232: ...icy index enable Disables access control of the specified policy Parameter Parameter name Description index Specify the policy index number Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range index 1 to 65535 Note Parameter name Note None None ...

Страница 233: ... target all ports 4 Associate configuration items above with policy 1 and set the policy sequence to 1 for application with top priority Fig 4 4 4 Example of the access control configuration 1 1 M24eGi enable M24eGi configure M24eGi config AccessControl classifier 1 dst net 192 168 1 0 24 M24eGi config AccessControl inprofile 1 deny M24eGi config AccessControl portlist 1 1 24 M24eGi config AccessC...

Страница 234: ... the access control 4 Configure the out profile to discard traffic exceeding 100 Mbps 5 Associate configuration items above with policy 2 and set the policy sequence to 10 Fig 4 4 5 Example of the access control configuration 2 1 2 3 4 5 M24eGi enable M24eGi configure M24eGi config AccessControl classifier 5 dscp 32 M24eGi config AccessControl inprofile 5 permit cos 6 M24eGi config AccessControl o...

Страница 235: ...leged mode Command to show the QoS configuration M24eGi show mls qos Command to show the CoS to que mapping configuration M24eGi show priority queue cos map Command to enable the QoS function M24eGi config mls qos Command to disable the QoS function M24eGi config no mls qos Command to configure the CoS to que mapping M24eGi config priority queue cos map priority traffic class ...

Страница 236: ...n 1 Quality of Service Status Shows the QoS operation status Enabled QoS is enabled Disabled QoS is disabled 2 Priority Shows the priority level of the VLAN frame 3 CoS Queue Shows the priority level of the queue M24eGi enable M24eGi show mls qos Quality of Service Status Disabled M24eGi show priority queue cos map Priority CoS Queue 0 0 1 0 2 1 3 1 4 2 5 2 6 3 7 3 M24eGi 1 3 2 ...

Страница 237: ...configuration information Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 238: ... level and mapping between the CoS value and queue Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 239: ...the QoS function Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None no mls qos The QoS function is disabled Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 240: ... the frame CoS value QUEUE Traffic class corresponding to the priority level Factory Default Setting Parameter name Factory default setting PRIORITY The factory default mapping initial state is as follows Priority CoS Queue 0 0 1 0 2 1 3 1 4 2 5 2 6 3 7 3 QUEUE Setting Range Parameter name Setting range PRIORITY 0 to 7 QUEUE 0 to 3 Note Parameter name Note PRIORITY None QUEUE None ...

Страница 241: ...ty value 0 to the Queue 1 2 Map the Priority value 1 to the Queue 0 3 Enable the QoS function Fig 4 5 2 Example of the QoS configuration M24eGi enable M24eGi configure M24eGi config priority queue cos map 0 1 M24eGi config priority queue cos map 1 0 M24eGi config mls qos M24eGi config exit M24eGi 1 2 3 ...

Страница 242: ...ivileged mode Command to configure the bandwidth control Interface configuration mode egress rate limit unit 1Mbps unit Command to enable the bandwidth control Interface configuration mode egress rate limit Command to disable the bandwidth control Interface configuration mode no egress rate limit Command to show the bandwidth control configuration Privileged mode show egress rate limit ...

Страница 243: ... or Disabled enabled The bandwidth control is enabled disabled The bandwidth control is disabled M24eGi enable M24eGi show egress rate limit Port Bandwidth Status 1 1000 disabled 2 1000 disabled 3 1000 disabled 4 1000 disabled 5 1000 disabled 6 1000 disabled 7 1000 disabled 8 1000 disabled 9 1000 disabled 10 1000 disabled 11 1000 disabled 12 1000 disabled 13 1000 disabled 14 1000 disabled 15 1000 ...

Страница 244: ...ntrol Parameter Parameter name Description unit 1Mbps unit Set the bandwidth Factory Default Setting Parameter name Factory default setting unit 1Mbps unit 1000 Mbps Setting Range Parameter name Setting range unit 1Mbps unit 1 to 1000 Note Parameter name Note unit 1Mbps unit None ...

Страница 245: ...ame Factory default setting None disabled Setting Range Parameter name Setting range None None Note Parameter name Note None None show egress rate limit Shows the configuration of bandwidth control Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None...

Страница 246: ...h 1 Enable the bandwidth control function 2 Set the bandwidth to 100 Mbps Fig 4 6 2 Example of the bandwidth control configuration M24eGi enable M24eGi configure M24eGi config interface gi0 1 M24eGi config if egress rate limit M24eGi config if egress rate limit 100 M24eGi config if end M24eGi 1 2 ...

Страница 247: ... config if no storm control broadcast Command to enable the storm control multicast M24eGi config if storm control multicast Command to disable the storm control multicast M24eGi config if no storm control multicast Command to enable the storm control unicast M24eGi config if storm control unicast Command to disable the storm control unicast M24eGi config if no storm control unicast Command to set...

Страница 248: ...torm control Interface DLF Broadcast Multicast Threshold 1 disabled disabled disabled 0 2 disabled disabled disabled 0 3 disabled disabled disabled 0 4 disabled disabled disabled 0 5 disabled disabled disabled 0 6 disabled disabled disabled 0 7 disabled disabled disabled 0 8 disabled disabled disabled 0 9 disabled disabled disabled 0 10 disabled disabled disabled 0 11 disabled disabled disabled 0 ...

Страница 249: ...storm control configuration Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 250: ...storm control for broadcast packets Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None no storm control broadcast The storm control for broadcast packets is disabled Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 251: ...storm control for multicast packets Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None no storm control multicast The storm control for multicast packets is disabled Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 252: ...l for unicast packets with unknown destination Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None no storm control unicast The storm control for unicast packets with unknown destination is disabled Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 253: ... multicast packets The unit is the number of packets received per second Packet Per Second Factory Default Setting Parameter name Factory default setting pps 0 Setting Range Parameter name Setting range pps 0 to 262143 Note Parameter name Note pps The threshold is not a total number of thresholds for unknown destination unicast broadcast and multicast packets The threshold is applied to each packe...

Страница 254: ...tion mode for Port 1 2 Enable the storm control for broadcast packets on Port 1 3 Set the threshold for receiving broadcast packets on Port 1 to 10000 pps Fig 4 7 2 Example of the storm control configuration M24eGi enable M24eGi configure M24eGi config interface gi0 1 M24eGi config if storm control broadcast M24eGi config if storm control threshold 10000 M24eGi config if end M24eGi 1 2 3 ...

Страница 255: ...s attribute Command without RADIUS Attribute M24eGi config no authentication dynamic vlan radius attribute Guest VLAN configuration command M24eGi config if authentication guest vlan vlan id Guest VLAN delete command M24eGi config if no authentication guest vlan Default VLAN configuration command M24eGi config if authentication default vlan vlan id Default VLAN delete command M24eGi config if no a...

Страница 256: ...ntication operation of entire device Enabled Indicates that the WEB authentication is enabled Disabled Indicates that the WEB authentication is disabled 2 Configuring Target Port for Authentication 802 1X Port based Auth Ports Displays ports with IEEE802 1X port based authentication enabled 802 1X MAC based Auth Ports Displays ports with IEEE802 1X MAC based authentication enabled MAC Auth Ports D...

Страница 257: ...lays the MAC address of the target terminal for authentication Auth Type Displays the authentication method Displays the authentication method in successful authentication if the authentication status is Authorized or the authentication method while listening if the authentication status is Unauthorized 1X MAC WEB Indicates one of 802 1X MAC and WEB authentications 1X MAC Indicates either of 802 1...

Страница 258: ...thorized Unauthorized Indicates that the authentication is unauthorized The communication in this status is limited to within Guest VLAN Remaining Aging Time Displays the remaining time before re authentication When the remaining time reaches 0 the authentication status becomes Unauthorized and the authentication process is executed again ...

Страница 259: ...02 1X port based authentication Unauthorized Indicates listening ports for IEEE802 1X MAC based MAC and WEB authentications Guest Displays VLAN ID of Guest VLAN You can only specify existing VLAN Default Displays VLAN ID of default VLAN You can only specify existing VLAN Specify VLAN you assign when approval for RADIUS Attribute is Enabled and also Tunnel Private Group ID is not notified by the RA...

Страница 260: ...arameter Parameter name Description min Configure the remaining time before re authentication in minutes Factory default setting Parameter name Factory default setting min 60 Value setting range Parameter name Setting range min 0 to 65535 Instructions Parameter name Instruction min None ...

Страница 261: ... Parameter name Description mac addr Specify MAC address on the authentication status table Factory default setting Parameter name Factory default setting mac addr None Value setting range Parameter name Setting range mac addr Only MAC address on the authentication status table Instructions Parameter name Instruction mac addr None ...

Страница 262: ... Disables Guest VLAN of the target port Parameter Parameter name Description vid Specify existing VLAN ID Factory default setting Parameter name Factory default setting vid None Value setting range Parameter name Setting range vid Only existing VLAN ID Instructions Parameter name Instruction vid None ...

Страница 263: ...an Disables default VLAN of the target port Parameter Parameter name Description vid Specify existing VLAN ID Factory default setting Parameter name Factory default setting vid None Value setting range Parameter name Setting range vid Only existing VLAN ID Instructions Parameter name Instruction vid None ...

Страница 264: ... function configuration Parameter Parameter name Description None None Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 265: ...r port Displays in ascending order of both the port number and MAC address portlist Displays a MAC address of the specified port optional Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range portlist Switch M24eGi 1 to 24 Switch M16eGi 1 to 16 Switch M8eGi 1 to 9 You can configure multiple ports Example 1 to 3 5 Instructions Para...

Страница 266: ...namic VLAN configuration Parameter Parameter name Description None None Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 267: ... Move to the interface configuration mode of port 1 2 Set Guest VLAN for Port 1 to100 Fig 4 8 4 Configuration example of authentication function M24eGi enable M24eGi configure M24eGi config interface gi0 1 1 M24eGi config if authentication guest vlan 100 2 M24eGi config if end M24eGi ...

Страница 268: ...ommand for MAC WEB authentication after authentication fails M24eGi config aaa authentication mac web auth fail action stop secondary db Local MAC database registration command M24eGi config aaa authentication auth mac mac addr vlan vid Local MAC database delete command M24eGi config no aaa authentication auth mac mac addr Local user database registration command M24eGi config aaa authentication a...

Страница 269: ...cation process factory default setting Auth Fail Action Displays action taken when authentication fails on Primary Database You cannot change it for IEEE802 1X authentication Stop Stop authentication process without execution of authentication on Secondary Database factory default setting Move to Secondary Database when both of the following conditions are met Primary Database is RADIUS and RADIUS...

Страница 270: ...r name Password Displays a user password encrypted is displayed if encryption is used VLAN Displays VLAN ID assigned after the authentication Auth Type Displays the authentication method that uses this account Both Indicates that it is used for 802 1X and WEB authentications WEB Indicates that it is only used for WEB authentication 802 1X Indicates that it is only used for 802 1X authentication M2...

Страница 271: ...r WEB authentication local none Specify Secondary Database in case that Primary Database is RADIUS server local Specify the local database none No authentication radius none Specify Secondary Database in case that Primary Database is Local radius Specify RADIUS server none No authentication Factory default setting Parameter name Factory default setting primary local secondary none Value setting ra...

Страница 272: ...condary Database in case that Primary Database is RADIUS server local Specify the local database none No authentication primary local secondary none Specify Primary Database to the local database Secondary Database to no authentication Factory default setting Parameter name Factory default setting primary local secondary none Value setting range Parameter name Setting range None None Instructions ...

Страница 273: ... Parameter name Description mac addr Specify the target MAC address vid Specify VLAN ID assigned after the authentication Factory default setting Parameter name Factory default setting mac addr None vid None Value setting range Parameter name Setting range mac addr Unicast MAC address vid 1 to 4094 Instructions Parameter name Instruction mac addr None ...

Страница 274: ...D assigned after the authentication both web dot1x Specify the authentication method that uses the account Authentication is denied if accessed with the authentication method other than the one specified here both Specify that the method is used for both WEB and 802 1X authentications web Specify that the method is only used for WEB authentication dot1x Specify that the method is only used for 802...

Страница 275: ...ption dot1x mac web Specify the target authentication type dot1x Specify the authentication method for IEEE802 1X authentication mac Specify the authentication method for MAC authentication web Specify the authentication method for WEB authentication Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Para...

Страница 276: ...ion auth mac auth user Specify the target local account type auth mac Specify the local MAC account auth user Specify the local user account Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 277: ...tabase of MAC authentication to RADIUS and secondary database to Local 2 Set Auth Fail Action of MAC authentication to secondary database 3 Add XX XX XX XX XX XX to local MAC database Specify VLAN 1 to VLAN following authentication Fig 4 9 3 Configuration example of authentication function M24eGi enable M24eGi configure M24eGi config aaa authentication mac primary radius secondary local 1 M24eGi c...

Страница 278: ...play the authentication log in Privileged mode Authentication log retention period configuration command M24eGi config syslog authentication save interval min Authentication log delete command M24eGi config syslog authentication clear Authentication log display command M24eGi show syslog authentication tail line ...

Страница 279: ...show syslog authentication tail 5 2001 01 01 09 33 26 MAC RADIUS Rejected 00 00 07 00 09 07 on Port 3 2001 01 01 09 33 26 MAC RADIUS Rejected 00 00 07 00 09 08 on Port 3 2001 01 01 09 33 26 MAC RADIUS Rejected 00 00 07 00 09 09 on Port 3 2001 01 01 09 33 26 MAC RADIUS Rejected 00 00 07 00 09 0A on Port 3 2001 01 02 08 33 25 WEB Local Authorized user test xx xx xx xx xx xx on Port 1 to VLAN 1 M24eG...

Страница 280: ...hentication log flash Parameter Parameter name Description min Configure the interval of the write operation in minutes Factory default setting Parameter name Factory default setting min 60 Value setting range Parameter name Setting range min 1 to 1440 Instructions Parameter name Instruction None None ...

Страница 281: ...thentication log Parameter Parameter name Description None None Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 282: ...l line Specify for the latest log displayed with the specified number of rows optional line Specify the number of rows displayed Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range line 1 to 512 Instructions Parameter name Instruction None None ...

Страница 283: ...te operation to the authentication log flash to 10 minutes 1 Configure the interval to 10 minutes Fig 4 10 2 Configuration example of authentication log M24eGi enable M24eGi configure M24eGi config syslog authentication save interval 10 1 M24eGi config end M24eGi ...

Страница 284: ...iguration command M24eGi config if dot1x port control auto force authorized force unauthorized Local re authentication interval configuration and enable command M24eGi config if dot1x re auth timer local Local re authentication interval configuration and enable delete command M24eGi config if no dot1x re auth timer local Re authentication status initialization command M24eGi config if dot1x re aut...

Страница 285: ...n is enabled The authentication process relay is performed between the client and authentication server Force Unauthorize d The access control function is disabled All authentication requests from the client are ignored Force Authorized The access control function is disabled Communication of the port is possible without authorization factory default setting Transmission Period The number of secon...

Страница 286: ...authentication is not performed factory default setting OperControlDirection Displays the operation status at the time of authentication request Both In an unauthorized status the packet transmission reception is not executed In In an unauthorized status the packet reception is not executed AdminControlDirecti on Displays the operation configuration at the time of authentication request Both In an...

Страница 287: ...287 priority and used factory default setting Local The value of Re auth Period of this device is always used ...

Страница 288: ...t Specify the port number list displayed Factory default setting Parameter name Factory default setting port list None Value setting range Parameter name Setting range port list Switch M24eGi 1 to 24 Switch M16eGi 1 to 16 Switch M8eGi 1 to 9 You can configure multiple ports Example 1 to 3 5 Instructions Parameter name Instruction port list None ...

Страница 289: ...ication Note This command is executed from interface configuration mode of each port Parameter Parameter name Description None None Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 290: ...ted from interface configuration mode of each port Parameter Parameter name Description None None Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 291: ...rface configuration mode of each port Parameter Parameter name Description value Configure the maximum number of times of retransmitting an authentication request Factory default setting Parameter name Factory default setting value 2 Value setting range Parameter name Setting range value 1 to 10 Instructions Parameter name Instruction value None ...

Страница 292: ...ent and authentication server force authorized The access control function is disabled Communication of the port is possible without authorization force unauthorized The access control function is disabled All authentication requests from the client are ignored Factory default setting Parameter name Factory default setting auto force authorized force unauthorized force authorized Value setting ran...

Страница 293: ...293 ...

Страница 294: ...e This command is executed from interface configuration mode of each port Parameter Parameter name Description None Align the number of seconds to wait before requesting the client to reattempt authentication with the switch configuration Factory default setting Parameter name Factory default setting None Align the number of seconds to wait before requesting the client to reattempt authentication ...

Страница 295: ...mmand is executed from interface configuration mode of each port Parameter Parameter name Description None None Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 296: ...Note This command is executed from interface configuration mode of each port Parameter Parameter name Description None None Factory default setting Parameter name Factory default setting None Periodic re authentication is disabled Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 297: ...erface configuration mode of each port Parameter Parameter name Description seconds Configure the number of seconds to wait before reattempting a failed authentication Factory default setting Parameter name Factory default setting seconds 60 Value setting range Parameter name Setting range seconds 1 to 65535 Instructions Parameter name Instruction seconds None ...

Страница 298: ...mmand is executed from interface configuration mode of each port Parameter Parameter name Description seconds The periodic re authentication time interval Factory default setting Parameter name Factory default setting seconds 3600 Value setting range Parameter name Setting range seconds 1 to 65535 Instructions Parameter name Instruction seconds None ...

Страница 299: ...ace configuration mode of each port Parameter Parameter name Description seconds Configure the timeout for the authentication server Factory default setting Parameter name Factory default setting seconds 30 Value setting range Parameter name Setting range seconds 1 to 65535 Instructions Parameter name Instruction seconds None ...

Страница 300: ...erface configuration mode of each port Parameter Parameter name Description seconds Configure the timeout for the client Factory default setting Parameter name Factory default setting seconds 30 Value setting range Parameter name Setting range seconds 1 to 65535 Instructions Parameter name Instruction seconds None ...

Страница 301: ...and is executed from interface configuration mode of each port Parameter Parameter name Description seconds Configure the number of seconds to wait before requesting to reattempt authentication Factory default setting Parameter name Factory default setting seconds 30 Value setting range Parameter name Setting range seconds 1 to 65535 Instructions Parameter name Instruction seconds None ...

Страница 302: ... 3 Enable periodic re authentication to the client for Port 1 4 Make change to align the number of seconds to wait before requesting to reattempt authentication for Port 1 with the switch configuration 5 Set the number of seconds to wait before requesting to reattempt authentication for Port 1 to 6000 seconds Fig 4 11 2 Configuration example of IEEE802 1X port based authentication M24eGi enable M2...

Страница 303: ...M24eGi config if dot1x max req value Authentication operation configuration command M24eGi config if dot1x port control auto force authorized force unauthorized Local re authentication interval configuration and enable command M24eGi config if dot1x re auth timer local Local re authentication interval configuration and enable delete command M24eGi config if no dot1x re auth timer local Re authenti...

Страница 304: ...nterval configuration command for sending EAP Request M24eGi config dot1x eap request interval sec EAP Request enable command M24eGi config if dot1x eap request EAP Request disable command M24eGi config if no dot1x eap request Force Authorized MAC Address configuration command M24eGi config dot1x forceAuthorized mac MAC mask bit mask len auth mode authorized unauthorized portlist port list Force A...

Страница 305: ...trol configuration in an unauthorized status Both In an unauthorized status the packet transmission reception is not executed In In an unauthorized status the packet reception is not executed Transmission Period Displays the number of seconds to wait before requesting the supplicant to reattempt authentication The factory default setting is 30 seconds Supplicant Timeout Displays the timeout for th...

Страница 306: ... Enabled Re authentication is performed periodically Disabled Periodic re authentication is not performed factory default setting Re Auth Timer Mode Displays whether this value is used or not when Session Timeout Attribute was notified by RADIUS server RADIUS The value of Session Timeout is given priority and used factory default setting Local The value of Re auth Period of this device is always u...

Страница 307: ...rized Indicates that the authentication is authorized Unauthorize d Indicates it is in an unauthorized status Re auth Displays the re authentication status for each supplicant Enabled Re authentication is performed Disabled Re authentication is not performed ...

Страница 308: ...name Description port num Specify the target port number Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range port num Switch M24eGi 1 to 24 Switch M16eGi 1 to 16 Switch M8eGi 1 to 9 Instructions Parameter name Instruction None None ...

Страница 309: ...MAC Specify the display range all Displays all the entries single Only displays specified MAC address MAC Specify the target MAC address Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range MAC Forced authentication MAC address Instructions Parameter name Instruction None None ...

Страница 310: ...ecify the target interface name mac Displays in the order of MAC address Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range interface name Switch M24eGi GigabitEthernet0 1 GigabitEthernet0 24 Switch M16eGi GigabitEthernet0 1 GigabitEthernet0 16 Switch M8eGi GigabitEthernet0 1 GigabitEthernet0 9 Abbreviations can be used Example...

Страница 311: ...EAP Request configuration Parameter Parameter name Description None None Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 312: ...since up Specify the type of statistic information displayed since reset Displays the value from the counter reset since up Displays the value from device start up Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range port num Switch M24eGi 1 to 24 Switch M16eGi 1 to 16 Switch M8eGi 1 to 9 Instructions Parameter name Instruction N...

Страница 313: ...cation Note This command is executed from interface configuration mode of each port Parameter Parameter name Description None None Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 314: ...tion both In the unauthorized status transmitting and receiving packets through the target port are not executed on this device in In the unauthorized status receiving packets through the target port is not executed on this device Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Parameter name Instructi...

Страница 315: ...de of each port Parameter Parameter name Description MAC Specify the MAC address of supplicants for which authentication is initialized optional Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range MAC MAC address on the authentication table Instructions Parameter name Instruction None None ...

Страница 316: ...face configuration mode of each port Parameter Parameter name Description MAC Only specify to specific supplicants optional Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range MAC MAC address on the authentication table Instructions Parameter name Instruction None None ...

Страница 317: ...executed from interface configuration mode of each port Parameter Parameter name Description MAC Only specify to specific supplicants optional Factory default setting Parameter name Factory default setting None Periodic re authentication is disabled Value setting range Parameter name Setting range MAC MAC address on the authentication table Instructions Parameter name Instruction None None ...

Страница 318: ...nauthorized MAC address Parameter Parameter name Description sec Configure the transmission interval in minutes of EAP Request Factory default setting Parameter name Factory default setting sec 5 Value setting range Parameter name Setting range sec 1 to 3600 Instructions Parameter name Instruction None None ...

Страница 319: ... Request Note This command is executed from interface configuration mode of each port Parameter Parameter name Description None None Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 320: ...ecified MAC address authorized unauthorized Specify the authentication method authorized Indicates the forced authentication unauthorized Indicates the forced unauthorized authentication portlist Specify the target port list Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range MAC Unicast MAC address mask len 1 to 48 portlist Swi...

Страница 321: ...o which EAP Request is sent Parameter Parameter name Description sec Configure the age timeout in seconds of the unauthorized MAC address table Factory default setting Parameter name Factory default setting sec 300 Value setting range Parameter name Setting range sec 0 to 65535 Instructions Parameter name Instruction None None ...

Страница 322: ...interface name Specify the target interface name Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range MAC Unicast MAC address interface name Switch M24eGi 1 to 24 Switch M16eGi 1 to 16 Switch M8eGi 1 to 9 You can configure multiple ports Example 1 to 3 5 Instructions Parameter name Instruction None None ...

Страница 323: ...e for Port 1 2 Set the IEEE802 1X authentication method for Port 1 to MAC based authentication 3 Enable the transmission function of EAP Request for Port 1 Fig 4 12 2 Configuration example of IEEE802 1X MAC based authentication M24eGi enable M24eGi configure M24eGi config interface gi0 1 1 M24eGi config if dot1x port auth mode mac based 2 M24eGi config if dot1x eap request 3 M24eGi config if end M...

Страница 324: ...t configuration command type of delimiter M24eGi config mac authentication mac format delimiter hyphen colon dot none RADIUS server user name format configuration command number of characters delimited M24eGi config mac authentication mac format delimited char num 2 4 6 RADIUS server password format configuration command M24eGi config mac authentication password mac manual RADIUS server fixed pass...

Страница 325: ...t setting Colon Indicates that a colon is used Dot Indicates that a dot is used None Indicates that no delimiter is used Delimited Characters Specify the number of characters delimited in MAC address sent to RADIUS server as a user name 2 Indicates delimiting every two characters factory default setting 4 Indicates delimiting every four characters 6 Indicates delimiting every six characters RADIUS...

Страница 326: ...tes using the same string as MAC address factory default setting Manual Indicates using an arbitrary fixed string Manual Password Displays a fixed string sent as a password when RADIUS Password Type is set to Manual ...

Страница 327: ...ntication configuration Parameter Parameter name Description None None Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 328: ...tication Disable the MAC authentication function Parameter Parameter name Description None None Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 329: ... after MAC authentication fails Parameter Parameter name Description sec Specify the time period in seconds before authentication process is accepted Factory default setting Parameter name Factory default setting sec 60 Value setting range Parameter name Setting range sec 1 to 65535 Instructions Parameter name Instruction None None ...

Страница 330: ... is used for MAC authentication Parameter Parameter name Description upper lower Specify upper or lower case upper Indicates upper case lower Indicates lower case Factory default setting Parameter name Factory default setting upper lower upper Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 331: ...name Description hyphen colon dot none Specify the type of delimiter hyphen Indicates that a hyphen is used colon Indicates that a colon is used dot Indicates that a dot is used none Indicates that no delimiter is used Factory default setting Parameter name Factory default setting hyphen colon dot none hyphen Value setting range Parameter name Setting range None None Instructions Parameter name In...

Страница 332: ...ion Parameter Parameter name Description 2 4 6 Specify the type of delimiter 2 Indicates delimiting every two characters 4 Indicates delimiting every four characters 6 Indicates delimiting every six characters Factory default setting Parameter name Factory default setting 2 4 6 2 Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 333: ...cription mac manual Indicates the type of a password string sent to RADIUS server mac Indicates using the same MAC address format string as a user name manual Indicates using an arbitrary fixed string Factory default setting Parameter name Factory default setting mac manual mac Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 334: ... mac authentication password manual Clear the configuration of the fixed string Parameter Parameter name Description string Specify the fixed string Factory default setting Parameter name Factory default setting string None Value setting range Parameter name Setting range string 1 to 32 alphanumeric characters Instructions Parameter name Instruction None None ...

Страница 335: ...ter name Description portlist Specify the target port for MAC authentication Factory default setting Parameter name Factory default setting portlist None Value setting range Parameter name Setting range portlist Switch M24eGi 1 to 24 Switch M16eGi 1 to 16 Switch M8eGi 1 to 9 You can configure multiple ports Example 1 to 3 5 Instructions Parameter name Instruction None None ...

Страница 336: ... XX XX XX to local MAC database to assign it to VLAN 1 4 Specify Port 1 2 as target ports for MAC authentication 5 Enable MAC authentication Fig 4 13 2 Configuration example of MAC authentication local database authentication M24eGi enable M24eGi configure M24eGi config interface GigabitEthernet0 1 2 1 M24eGi config if pvid 100 2 M24eGi config if exit M24eGi config aaa authentication auth mac XX X...

Страница 337: ...nel Private Group Id 1 1 Set Primary Database for MAC authentication to RADIUS 2 Move to the interface configuration mode for Port 1 2 3 Change PVID for Port 1 2 to 100 4 Specify Port 1 2 as target ports for MAC authentication 5 Enable MAC authentication Fig 4 13 3 Configuration example of MAC authentication RADIUS authentication M24eGi enable M24eGi configure M24eGi config aaa authentication mac ...

Страница 338: ...een and HTTP port initialization command M24eGi config no web authentication web port Redirect URL configuration command M24eGi config web authentication redirect URL Redirect URL delete command M24eGi config no web authentication redirect WEB authentication login screen and title configuration command M24eGi config web authentication contents title string WEB authentication login screen and user ...

Страница 339: ...dhcp lease time sec Default router configuration command M24eGi config web authentication dhcp default router IP Default router configuration and delete command M24eGi config no web authentication dhcp default router DNS server address configuration command M24eGi config web authentication dhcp dns IP DNS server address configuration and delete command M24eGi config no web authentication dhcp dns ...

Страница 340: ...iguration display command Virtual IP Address Displays the virtual IP address used in the WEB authentication login screen HTTP Port Number Used in the WEB authentication login screen Redirect URL Displays URL viewed as redirection occurs after successful WEB authentication M24eGi enable M24eGi show web authentication Virtual IP Address 0 0 0 0 HTTP Port Number 80 Redirect URL M24eGi ...

Страница 341: ...actory default User Name String Displays a string in the user name input field factory default setting User Name You can enter the user name in Japanese using Unicode Password String Displays a string in the password input field factory default setting Password You can enter the password in Japanese using Unicode Message Displays the text shown in the Message filed You can enter the text in Japane...

Страница 342: ...342 are disabled a b i u center right left font h1 to h5 div span br p ...

Страница 343: ...use DHCP server is disabled factory default setting DHCP Lease Time Displays IP address lease time in seconds factory default setting 30 Start of Leased IP Address Displays start address of leased IP address Subnet mask is fixed to 255 255 255 0 Number of Leased IP Address Displays the number of leased IP addresses factory default setting 32 Default Router Address Displays the value of default rou...

Страница 344: ...in screen page configuration show web authentication dhcp Displays the temporary use DHCP server configuration Parameter Parameter name Description None None Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 345: ...tication Disable the WEB authentication function Parameter Parameter name Description None None Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 346: ... after WEB authentication fails Parameter Parameter name Description sec Specify the time period in seconds before authentication process is accepted Factory default setting Parameter name Factory default setting sec 60 Value setting range Parameter name Setting range sec 1 to 65535 Instructions Parameter name Instruction None None ...

Страница 347: ...ter name Description portlist Specify the target port for WEB authentication Factory default setting Parameter name Factory default setting portlist None Value setting range Parameter name Setting range portlist Switch M24eGi 1 to 24 Switch M16eGi 1 to 16 Switch M8eGi 1 to 9 You can configure multiple ports Example 1 to 3 5 Instructions Parameter name Instruction None None ...

Страница 348: ...ess used in the WEB authentication login screen Factory default setting Parameter name Factory default setting IP 0 0 0 0 Value setting range Parameter name Setting range IP Arbitrary IP address other than 0 0 0 0 224 0 0 0 to 255 255 255 255 as well as network address actually connected Instructions Parameter name Instruction IP Specify an IP address such as 1 1 1 1 for the network address used f...

Страница 349: ...escription l4 port Specify the HTTP port number used in the WEB authentication login screen Factory default setting Parameter name Factory default setting l4 port 80 Value setting range Parameter name Setting range l4 port 1 to 65535 Instructions Parameter name Instruction l4 port When changing this setting the HTTP port number in the WEB configuration screen is also changed You cannot specify the...

Страница 350: ... URL configuration Parameter Parameter name Description URL Specify the virtual IP address used in the WEB authentication login screen Factory default setting Parameter name Factory default setting URL None Value setting range Parameter name Setting range URL URL starting with http containing 64 characters or less Instructions Parameter name Instruction None None ...

Страница 351: ...tents title Clear the title string Parameter Parameter name Description string Specify the title string Factory default setting Parameter name Factory default setting string None Value setting range Parameter name Setting range string 64 alphanumeric and Unicode UTF 8 characters or less Instructions Parameter name Instruction None None ...

Страница 352: ...e Clear the string in the user name input field Parameter Parameter name Description string Specify a string in the user name input field Factory default setting Parameter name Factory default setting string User Name Value setting range Parameter name Setting range string 32 alphanumeric and Unicode UTF 8 characters or less Instructions Parameter name Instruction None None ...

Страница 353: ...rd Clear the string in the password input field Parameter Parameter name Description string Specify a string in the password input field Factory default setting Parameter name Factory default setting string Password Value setting range Parameter name Setting range string 32 alphanumeric and Unicode UTF 8 characters or less Instructions Parameter name Instruction None None ...

Страница 354: ...ver IP Specify the IP address of TFTP server with the logo data stored filename Specify the logo data file name on TFTP server Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range server IP Unicast IP address filename 39 alphanumeric characters or less Instructions Parameter name Instruction filename You can specify a JPG GIF PNG...

Страница 355: ... Parameter Parameter name Description string Specify a string in the message field Factory default setting Parameter name Factory default setting string None Value setting range Parameter name Setting range string 256 alphanumeric and Unicode UTF 8 characters or less Instructions Parameter name Instruction string You can use the following HTML tags a b i u center right left font h1 to h5 div span ...

Страница 356: ...ield Parameter Parameter name Description string Specify a string in the description field Factory default setting Parameter name Factory default setting string None Value setting range Parameter name Setting range string 256 alphanumeric and Unicode UTF 8 characters or less Instructions Parameter name Instruction string You can use the following HTML tags a b i u center right left font h1 to h5 d...

Страница 357: ...cation dhcp disable Disable temporary use DHCP server Parameter Parameter name Description None None Factory default setting Parameter name Factory default setting None None Value setting range Parameter name Setting range None None Instructions Parameter name Instruction None None ...

Страница 358: ...ress Parameter Parameter name Description IP Specify start address of leased IP address Factory default setting Parameter name Factory default setting IP 0 0 0 0 Value setting range Parameter name Setting range IP Unicast IP address Instructions Parameter name Instruction None None ...

Страница 359: ...dresses Parameter Parameter name Description ip num Specify the number of leased IP addresses Factory default setting Parameter name Factory default setting ip num 32 Value setting range Parameter name Setting range ip num 1 to 64 Instructions Parameter name Instruction None None ...

Страница 360: ... in seconds Parameter Parameter name Description sec Specify IP address lease time in seconds Factory default setting Parameter name Factory default setting sec 30 Value setting range Parameter name Setting range sec 30 to 60 Instructions Parameter name Instruction None None ...

Страница 361: ...guration Parameter Parameter name Description IP Specify default router IP address notified in DHCP Factory default setting Parameter name Factory default setting IP None Value setting range Parameter name Setting range IP Communication capable IP address existing in Guest VLAN Instructions Parameter name Instruction IP Specify IP address actually existing in Guest VLAN ...

Страница 362: ...Clear the configuration of DNS server Parameter Parameter name Description IP Specify IP address of DNS server notified in DHCP Factory default setting Parameter name Factory default setting IP None Value setting range Parameter name Setting range IP Unicast IP address Instructions Parameter name Instruction None None ...

Страница 363: ...n method WEB authentication only 4 Specify Port 1 2 as target ports for WEB authentication 5 Specify virtual IP address to 1 1 1 1 6 Enable WEB authentication Fig 4 14 2 Configuration example of WEB authentication local database authentication M24eGi enable M24eGi configure M24eGi config interface GigabitEthernet0 1 2 1 M24eGi config if pvid 100 2 M24eGi config if exit M24eGi config aaa authentica...

Страница 364: ... Global configuration mode Confirm the configuration information by executing the show led base mode command in Privileged mode Command to show the LED base mode M24eGi show led base mode Command to configure the LED base mode M24eGi config led base mode status l eco ...

Страница 365: ...se mode is shown below Fig 4 8 1 Example of executing the command to show the LED base mode 1 System LED base mode Shows the LED base mode Status Operating in the status mode Eco Operating in the eco mode M24eGi enable M24eGi show led base mode System LED base mode Status M24eGi 1 ...

Страница 366: ...LED base mode configuration Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 367: ...he status mode if the LED display change button is not pressed for 1 minute eco Automatically switches to the eco mode if the LED display change button is not pressed for 1 minute Factory Default Setting Parameter name Factory default setting status eco status Setting Range Parameter name Setting range status eco Either status or eco Note Parameter name Note status eco None ...

Страница 368: ...D base mode 1 Set to the eco mode Fig 4 8 2 Example of the LED base mode configuration Note Change in configuration of the LED base mode is automatically saved M24eGi enable M24eGi configure M24eGi config led base mode eco M24eGi config exit M24eGi 1 ...

Страница 369: ...de Command to show the loop history M24eGi show line loopback history tail line Command to delete the loop history M24eGi line loopback history clear Command to enable the loop detection function M24eGi config if line loopback Command to disable the loop detection function M24eGi config if no line loopback Command to configure the loop detection mode M24eGi config if line loopback mode block l shu...

Страница 370: ... from the shut off state of Port 1 at 6 35 17 on January 1st 3 History display example 3 Shows that loops were detected on Port 2 and Port 3 at 10 39 26 on January 1st and were shut off Note For details of loop history messages refer to the section of system log in chapter 10 M24eGi enable M24eGi show line loopback history Jan 01 06 34 17 kern info LINE PROTOCOL The loop detected on port 1 Jun 01 ...

Страница 371: ...he Switching Hub Parameter Parameter name Description line Set the number of lines to be displayed from the log end Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range line 1 to 64 Note Parameter name Note None None ...

Страница 372: ... Factory Default Setting Parameter name Factory default setting None Switch M24eGi Ports 1 to 22 line loopback Ports 23 to 24 no line loopback Switch M16eGi Ports 1 to 14 line loopback Ports 15 to 16 no line loopback Switch M8eGi Ports 1 to 7 line loopback Ports 8 to 9 no line loopback Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 373: ...e block When the Switching Hub detects loop the ports are blocked Factory default setting shutdown When the Switching Hub detects loop the ports are shut down Factory Default Setting Parameter name Factory default setting block l shutdown block Setting Range Parameter name Setting range block l shutdown Either block or shutdown Note Parameter name Note None None ...

Страница 374: ...auto recovery function Parameter Parameter name Description sec Set the time between the loop shut off and the auto recovery The unit is seconds Factory Default Setting Parameter name Factory default setting sec 60 Setting Range Parameter name Setting range sec 60 to 86400 Note Parameter name Note sec None ...

Страница 375: ...etecting a loop on Port 1 and shutting down the port Fig 4 9 2 Example of configuration of the loop detection shut off and auto recovery functions Note For loop detection a unique frame is used If a loop detection frame is received on a port whose loop detection shut off function is disabled the destination port is shut down M24eGi enable M24eGi configure M24eGi config interface gi0 1 M24eGi confi...

Страница 376: ... function for automatically detecting the port connection status and minimizing power consumption if not connected This Switching Hub supports two modes the Half mode for giving priority to connectivity with other device and the Full mode for minimizing power consumption Command to configure the MNO series power saving mode M24eGi config if line power saving disable full half ...

Страница 377: ... power saving mode is disabled full The MNO series power saving mode is enabled half The MNO series power saving mode that gives priority to connectivity with other device is adopted Factory Default Setting Parameter name Factory default setting disable full half half Setting Range Parameter name Setting range disable full half Either disable full or half Note Parameter name Note disable full half...

Страница 378: ...figuration mode for Ports 1 to 24 2 Enable the MNO series power saving mode on Ports 1 to 24 Fig 4 9 3 Example of executing the command to configure the MNO series power saving mode M24eGi enable M24eGi configure M24eGi config interface gi0 1 24 M24eGi config if line power saving full M24eGi config if end M24eGi 1 2 ...

Страница 379: ...Display Confirm the configuration of loop detection shut off function and MNO series power saving mode in Interface configuration mode Command to show the configuration of MNO series power saving mode M24eGi show line configuration ...

Страница 380: ...ce Status Mode Loop detection Power saving gi0 1 Down Auto Enabled Half gi0 2 Down Auto Enabled Half gi0 3 Down Auto Enabled Half gi0 4 Down Auto Enabled Half gi0 5 Down Auto Enabled Half gi0 6 Down Auto Enabled Half gi0 7 Down Auto Enabled Half gi0 8 Down Auto Enabled Half gi0 9 Down Auto Enabled Half gi0 10 Down Auto Enabled Half gi0 11 Down Auto Enabled Half gi0 12 Down Auto Enabled Half gi0 13...

Страница 381: ...rt is in the 100 Mbps half duplex mode 10 FDx 10F under the Auto mode The port is in the 10 Mbps full duplex mode 10 HDx 10H under the Auto mode The port is in the 10 Mbps half duplex mode 4 Loop detection Shows the status of the loop detection shut off function Enabled The loop detection shut off function is enabled Disabled The loop detection shut off function is disabled 5 Power saving Shows th...

Страница 382: ... can be assigned to multiple port groups Confirm the configuration information by executing the show port group command in Privileged mode Command to show the port group information M24eGi show port group Command to configure port grouping M24eGi config port group ID name Name member Portlist Command to enable port grouping M24eGi config port group ID enable Command to disable port grouping M24eGi...

Страница 383: ...n 1 Group ID Shows the port group ID 2 Group Name Shows the port group name 2 Group Member Shows member ports in the port group 3 Status Shows the status of port grouping Enabled Port grouping is enabled Disabled Port grouping is disabled M24eGi enable M24eGi show port group Total Groups 3 Group ID Group Name Group Member Status 1 Group_1 1 2 Enabled 2 Group_2 2 4 Disabled M24eGi 1 2 3 4 ...

Страница 384: ...port group configuration Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 385: ...tList Set member ports belonging to the port group Factory Default Setting Parameter name Factory default setting ID None Name None PortList None Setting Range Parameter name Setting range ID 1 to 256 Name Up to 15 one byte characters Allowed characters alphanumeric character A Z a z 0 9 symbol _ white space PortList Switch M24eGi 1 to 24 Switch M16eGi 1 to 16 Switch M8eGi 1 to 9 Multiple ports ca...

Страница 386: ...386 Note Parameter name Note ID None Name None PortList None ...

Страница 387: ... Parameter Parameter name Description ID Specify the port group ID Factory Default Setting Parameter name Factory default setting ID port group ID enable Port grouping is enabled at the time of configuration Setting Range Parameter name Setting range ID 1 to 256 Note Parameter name Note ID None ...

Страница 388: ...t group 1 member ports 1 to 3 2 Set up port group 2 member ports 2 to 4 3 Disable the port group 2 Fig 4 10 2 Example of the port group configuration M24eGi enable M24eGi configure M24eGi config port group 1 name Group_1 member 1 3 M24eGi config port group 2 name Group_2 member 2 4 M24eGi config no port group 2 enable M24eGi config end M24eGi 1 2 3 ...

Страница 389: ...e statistical information of packet counters in Privileged mode Command to show the statistical information normal M24eGi show interface counters IFNAME Command to show the statistical information error M24eGi show interface counters error IFNAME ...

Страница 390: ...s 290459 128to255 Octets 19582 256to511 Octets 175625 512to1023 Octets 17739 1024to1518 Octets 21 M24eGi show interface counters error gi0 24 Interface GigabitEthernet0 24 is active which has statistics Inbound FragmentsPkts 0 UndersizePkts 0 OversizePkts 0 DisacrdsPkts 605385 ErrorPkts 0 UnknownProtos 0 AlignError 0 CRCAlignErrors 0 Jabbers 0 DropEvents 0 Outbound Collisions 0 LateCollision 0 Sin...

Страница 391: ... interface counters gi0 24 Interface GigabitEthernet0 24 is active which has statistics Inbound Total Octets 135616937 BroadcastPkts 802649 MulticastPkts 195421 UnicastPkts 5019 Non unicastPkts 998008 Outbound Total Octets 1932746 UnicastPkts 27577 Non unicastPkts 62 Inbound packets distribution 64 Octets 527240 65to127 Octets 290459 128to255 Octets 19582 256to511 Octets 175625 512to1023 Octets 17...

Страница 392: ...r name Setting range IFNAME Switch M24eGi gi0 1 to gi0 24 A range can be specified with a hyphen None All ports are displayed Switch M16eGi gi0 1 to gi0 16 A range can be specified with a hyphen None All ports are displayed Switch M8eGi gi0 1 to gi0 9 A range can be specified with a hyphen None All ports are displayed Note Parameter name Note IFNAME None Note If the specified interface is not conn...

Страница 393: ...ter name Setting range IFNAME Switch M24eGi gi0 1 to gi0 24 A range can be specified with a hyphen None All ports are displayed Switch M16eGi gi0 1 to gi0 16 A range can be specified with a hyphen None All ports are displayed Switch M8eGi gi0 1 to gi0 9 A range can be specified with a hyphen None All ports are displayed Note Parameter name Note IFNAME None Note If the specified interface is not co...

Страница 394: ...on of this Switching Hub to TFTP server or retrieve it from TFTP server in Privileged mode Command to transfer the configuration file M24eGi copy running config tftp ip address filename Command to retrieve the configuration file M24eGi copy tftp ip address filename running config ...

Страница 395: ...ied name from a specified TFTP server Parameter Parameter name Description ip address Specify the IP address of TFTP server filename Specify the configuration file name Factory Default Setting Parameter name Factory default setting ip address None filename None Setting Range Parameter name Setting range ip address 1 0 0 1 to 223 255 254 254 filename 1 to 39 one byte alphanumeric characters Note Pa...

Страница 396: ...hose IP address is 172 16 1 1 2 Save the retrieved configuration information For details refer to chapter 11 To cancel the TFTP transfer process press Ctrl C during transfer Fig 6 2 Example of transferring the configuration information TFTP server this Switching Hub Note The configuration information is not automatically saved in this Switching Hub just by retrieving the configuration file from th...

Страница 397: ...397 7 Firmware Upgrade You can upgrade the firmware version of this Switching Hub in Privileged mode Firmware upgrade command M24eGi copy tftp ip address file_name image ...

Страница 398: ... Set the IP address of the TFTP server filename Set the file name of the firmware Factory Default Setting Parameter name Factory default setting ip address None filename None Setting Range Parameter name Setting range ip address 1 0 0 1 to 223 255 254 254 filename 1 to 39 one byte alphanumeric characters Note Parameter name Note ip address None filename None Note Make sure not to turn off power wh...

Страница 399: ...and saved 4 The system is automatically rebooted when upgrade is successful Fig 7 1 Example of upgrading the firmware version 1 3 4 2 M24eGi enable M24eGi copy tftp 192 168 1 1 pn28240iv10000 rom image This command will proceed system firmware update Y N y Verifying Firmware File PASSED Firmware File Size 1823015 bytes Verifying Checksum 0x4deb Check Firmware Type FIRMWARE Checking Firmware Versio...

Страница 400: ... mode Reboot type can be selected from the following three options Normal Restore to the factory default settings and Restore to the factory default settings except for IP address 8 1 Normal Reboot Reboot of the Switching Hub is executed Reboot command M24eGi reboot normal ...

Страница 401: ...ter name Description normal Specify an option for the reboot type of the Switching Hub normal Reboot Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 402: ... Overview Perform a reboot 1 Execute the reboot command 2 In execution confirmation press y to continue and n to cancel Fig 8 1 1 Example of reboot M24eGi enable M24eGi reboot default Are you sure to reboot the system Y N y 1 2 ...

Страница 403: ...lt Settings You can entirely initialize saved configuration and system information and restore to the factory default settings in Global configuration mode Reboot timer configuration command M24eGi config reboot default default except ip ...

Страница 404: ...ot type of the Switching Hub Default Restores to the factory default settings after reboot default except ip Restores to the factory default settings after reboot except for the IP address setting Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None Note Once initialized the configuration an...

Страница 405: ...tion to restore to the factory default settings 1 Restore to the factory default settings 2 In execution confirmation press y to continue and n to cancel Fig 8 2 1 Example of reboot M24eGi enable M24eGi reboot default Are you sure to reboot the system Y N y 1 2 ...

Страница 406: ...t Timer Configuration You can reboot the Switching Hub after a set time from execution of the reboot command by setting the reboot timer in advance Reboot timer configuration command M24eGi config reboot timer time ...

Страница 407: ... Switching Hub Parameter Parameter name Description time Set the time until the Switching Hub is rebooted by seconds Factory Default Setting Parameter name Factory default setting time 0 Reboot timer is disabled Setting Range Parameter name Setting range time 0 to 86400 Note Parameter name Note time None ...

Страница 408: ...nfirmation 4 The Switching Hub is rebooted after 10 seconds according to the reboot timer To cancel the reboot press Ctrl and C Fig 8 3 1 Example of executing the reboot timer M24eGi enable M24eGi configure M24eGi config reboot timer 10 M24eGi config exit M24eGi reboot normal Are you sure to reboot the system Y N y The system will reboot 10 seconds later You can press CTRL c to cancel it M24eGi 1 ...

Страница 409: ...409 9 Ping Execution You can confirm connectivity using the ping command Ping command All modes ping IP address n count w timeout ...

Страница 410: ...rget host count Set the number of ping requests to send timeout Set the timeout in seconds Factory Default Setting Parameter name Factory default setting IP address None count 3 timeout 3 Setting Range Parameter name Setting range IP address 0 0 0 1 to 223 255 255 255 count 1 to 10 timeout 1 to 5 Note Parameter name Note IP address None count None timeout None ...

Страница 411: ...re displayed Fig 9 2 Example of ping execution 2 M24eGi ping 192 168 1 10 w 2 n 5 M24eGi PING 192 168 1 10 192 168 1 10 56 data bytes 64 bytes from 192 168 1 10 icmp_seq 0 time 10 ms 64 bytes from 192 168 1 10 icmp_seq 1 time 10 ms 64 bytes from 192 168 1 10 icmp_seq 2 time 10 ms 64 bytes from 192 168 1 10 icmp_seq 3 time 10 ms 64 bytes from 192 168 1 10 icmp_seq 4 time 10 ms 192 168 1 10 PING Sta...

Страница 412: ...412 10 System Log Display Display or delete the system log in Privileged mode Command to show the system log M24eGi show syslog tail line Command to delete the system log M24eGi syslog clear ...

Страница 413: ...24eGi show syslog tail 10 Jan 01 09 01 55 kern info SYSTEM Reboot the system Jan 01 09 00 12 kern info PORT Port 1 link up Jan 01 09 00 38 kern info SNTP SNTP first update to 2019 09 30 15 00 53 Jun 28 15 00 55 kern info SYSTEM Login from console Jun 29 19 21 04 kern info SYSTEM Configuration changed Jun 30 10 43 31 kern info PORT Port 17 link up Jun 30 10 43 32 kern info LINE PROTOCOL The loop de...

Страница 414: ... packet over 1518 Bytes Received the error packets Fragments Indicates that receiving Fragment frame Received the error packets Jabbers Indicates that receiving Jabber frame Received the error packets Collisions Indicates the detecting Collision Cannot send the packets Ping Indicate that cannot send the packet Cannot send the packets Telnet Indicate that cannot send the packet Cannot send the pack...

Страница 415: ...RADIUS Info Accept Login via RADIUS Indicates that the login operation was executed via RADIUS and was successful Error Reject Login via RADIUS Indicates that the login operation was executed via RADIUS and was rejected RADIUS Timeout Indicates that the login operation was executed via RADIUS and was timeout SNTP Info SNTP update to yyyy mm dd hh mm ss Indicates the time synchronized with SNTP ser...

Страница 416: ...s broken and was copied the configuration file 1 to 2 Reset configuration 1 2 to default Indicates that detected the configuration file 1 and 2 is broken and the configuration is initialized Copy configuration 2 to 1 is failed Indicates that detected the configuration file 1 is broken the copying the configuration file 2 to 1 is failed Copy configuration 1 to 2 is failed Indicates that detected th...

Страница 417: ...TELNET and was rejected based on TELNET access limitation function System authentication failure Indicates that authentication from the SNMP manager failed Info Set IP via ipsetup interface IP xxx xxx xxx xxx Indicates that IP address was set from the host with IP address xxx xxx xxx xxx via IP setup interface function Error Failed to set IP via ipsetup interface Indicates that IP address setting ...

Страница 418: ... to the factory default Reboot Factory Default Except IP Indicates that Switching Hub was rebooted in the mode to return settings other than IP address to the factory default Start reboot timer xxx sec Indicates that started the reboot timer Stop reboot timer Indicates that stopped the reboot timer Cleared system log Indicates that System log was cleared Error Watch dog timer is expired Indicates ...

Страница 419: ...Alarm Warning on Port x Indicates that SFP module status was changed RX power Indicates that SFP Rx power status was changed TX power Indicates that SFP Tx power status was changed Temperature Indicates that SFP temarature status was changed Votage Indicates that SFP voltage status was changed Bias current Indicates that SFP bias current status was changed Exceeded Indicates that SFP status exceed...

Страница 420: ...hing Hub Parameter Parameter name Description line Set the number of lines to be displayed from the log end Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range line 1 to 256 Note Parameter name Note None None ...

Страница 421: ...ears all logs Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 422: ...ort1 is authorized Jan 01 20 14 34 kern info LINE PROTOCOL The loop detected on port 1 Jan 01 20 16 00 kern info PORT Port1 is authorized Jan 01 20 16 00 kern info LINE PROTOCOL The loop detected on port 1 Jan 01 20 17 06 kern info PORT Port1 is authorized Jan 01 20 17 06 kern info LINE PROTOCOL The loop detected on port 1 Jan 01 22 42 29 kern info SYSTEM Success Reload system default config Jan 0...

Страница 423: ...ation information in Privileged mode Command to show the running configuration information M24eGi show running config Command to show the saved configuration information M24eGi show startup config Command to save the configuration information M24eGi copy running config startup config ...

Страница 424: ...aves the configuration information Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 425: ...n information that is currently running Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 426: ...ved configuration information Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 427: ...g config startup config Configuration saved to startup_config M24eGi show startup config M24eGi start of config file Software Version x x x xx Save date 20xx xx xx xx xx xx enable config ip address 192 168 0 1 255 255 255 0 192 168 0 254 terminal length 0 led base mode status console inactivity timer 0 telnet server inactivity timer 60 password manager 426D5A334B743077674359486F 1D0258C2440A8D19E7...

Страница 428: ... technical support information in Privileged mode It is useful if obtained before making inquiry It is recommended to set the terminal length to 0 because display contents are extremely large Command to show the technical support information M24eGi show tech ...

Страница 429: ...ical support information Parameter Parameter name Description None None Factory Default Setting Parameter name Factory default setting None None Setting Range Parameter name Setting range None None Note Parameter name Note None None ...

Страница 430: ...ystem CPU load BSD Syslog Protocol RFC 3164 System running configuration System information Interface operating status Interface configuration Interface packet counter Interface error packet counter IEEE 802 1Q Virtual Local Area Networks VLAN IEEE 802 3 Link Aggregation System ARP information Dynamic unicast MAC addresses aging time MAC address table System startup configuration M24eGi ...

Страница 431: ...431 Appendix A Specifications Refer to Operation Manual Menu Screens for your Switching Hub to read the specifications ...

Страница 432: ...figured only with the software Easy Config In the software the item is displayed as Camera name Restrictions The time for accepting setting changes is limited to 20 minutes after power on to ensure security However you can change settings regardless of the time limit if the IP address subnet mask default gateway user name and password values are the factory defaults You can check the current setti...

Страница 433: ...r directly uses In addition if a downstream Switching Hub is connected with a device such as a hub without loop detection function and a loop failure occurs under the device the downstream Switching Hub shuts down the corresponding port to prevent the failure from extending to the entire network Fig 1 Example of configuration using loop detection function Downstream Switching Hub 2 Downstream Swit...

Страница 434: ...witching hub causing loop will be blocked You need to examine this type of network configuration and the switching hub settings Fig 2 Precautions in using loop detection function Downstream switching hub 2 Downstream switching hub 1 Upstream switching hub PC 1 PC 2 PC 3 1 2 3 Conditions of occurrence 1 Communications between PC1 and PC2 and between PC1 and PC3 2 A loop occurs in downstream switchi...

Страница 435: ...u RO ifMtu port_num Shows the size without a header 1500 bytes ifSpeed RO ifSpeed port_num Shows the maximum port speed 1 Gbps ifPhysAddress RO ifPhysAddress port_num ifAdminStatus R W ifAdminStatus port_num Supports up and down ifOperStatus RO ifOperStatus port_num ifOLastChange RO ifOLastChange port_num ifInOctets RO ifInOctets port_num ifHCInOctets RO ifHCInOctets port_num ifInUcastPkts RO ifIn...

Страница 436: ...436 ifSpecific RO ifSpecific port_num ...

Страница 437: ...ntAddr ip_address ipAdEntIfIndex RO ipAdEntIfIndex ip_address ipAdEntNetMask RO ipAdEntNetMask ip_address ipAdEntBcastAddr RO ipAdEntBcastAddr ip_address ipAdEntReasmMaxSize RO ipAdEntReasmMaxSize ip_address ipNetToMediaIfIndex RO ipNetToMediaIfIndex ip_address ipNetToMediaPhysAddress RO ipNetToMediaPhysAddress ip_address ipNetToMediaNetAddress RO ipNetToMediaNetAddress ip_address ipNetToMediaType...

Страница 438: ...nmpInGetResponses 0 snmpInTraps RO snmpInTraps 0 snmpOutGetResponses RO snmpOutGetResponses 0 snmpOutTraps RO snmpOutTraps 0 1 7 dot1dBase group MIB object Access Identifier dot1dBaseBridgeAddress RO dot1dBaseBridgeAddress 0 dot1dBaseNumPorts RO dot1dBaseNumPorts 0 dot1dBaseType RO dot1dBaseType 0 dot1dBasePort RO dot1dBasePort port_num dot1dBasePortIfIndex RO dot1dBasePortIfIndex port_num dot1dBa...

Страница 439: ...1dTpPortInDiscards port_num 2 1 Supporting trap Trap description Access Identifier Link Up Down Login Failure Authentication Failure mnoLoopDetection ObjectID 1 3 6 1 4 1 396 5 5 2 1 mnoLoopRecovery ObjectID 1 3 6 1 4 1 396 5 5 2 2 mnoDdmAlarmTrap ObjectID 1 3 6 1 4 1 396 5 5 1 4 0 1 mnoDdmWarningTrap ObjectID 1 3 6 1 4 1 396 5 5 1 4 0 2 ...

Страница 440: ...OOP HISTORY LED blinks in orange This is to notify that there is a port in which a loop is occurring or has been removed within 3 days 2 Communications are slow Communications with all ports are impossible or slow Are the communication speed and mode settings correct If the communication mode signal cannot be properly obtained apply half duplex mode Switch the communication mode of the connection ...

Страница 441: ...n to the shop where you purchased this Switching Hub Product name Model No Product serial No 11 alphanumeric characters labeled on the product Firmware version The number after Ver labeled on the unit package Problem status Please give as concrete information as possible Within the warranty period Repair service will be provided in accordance with the conditions stipulated in the warranty card Ple...

Страница 442: ...racters labeled on the product Shop Sales company Tel Customer service contact Tel You can check the version on the screen described in chapter 3 of this manual Panasonic Life Solutions Networks Co Ltd 2019 2021 Panasonic Life Solutions Networks Co Ltd 2 12 7 Higashi Shimbashi Minato ku Tokyo Japan 105 0021 URL http panasonic co jp ls plsnw english P1019 2101 ...