PanaVoice Courier Installation Manual 26
3. Windows 98 Banner
The next program to boot is the Windows O/S. During this procedure, the Windows
98 banner will appear, and last for approximately 15 seconds.
4. Windows Desktop
The screen will then change to the desktop background, and will show the cursor
arrow and hourglass icon. After approximately 10 seconds, the Login and Password
are automatically entered for you and you will see 2 programs launching
simultaneously. These programs, PC Anywhere and the Voice Card Driver, will boot
very quickly.
These two programs will not appear on the task bar when they are finished.
5. Choose API Integrated or In-Band
The system will stop at this point and ask you to choose between API Integration
(API card installed in DBS), or In-Band Integration (DBS system without API card).
When you click
YES
or
NO
to this prompt, the Courier is configured appropriately.
Note: If the Courier is activated in API mode, it will expect the API link to be present at all
times. If the link is not present, the Courier will deactivate and reactivate itself approximately
every three minutes in an effort to re-establish the link. For this reason, if you wish to do
setup work on a Courier that will be integrated but is not currently connected to the API link,
you should activate the Courier in non-API mode so that setup can be completed. The mode
can then be changed to API when the system is properly connected to the DBS switch.
Note: Call Forwarding cannot be utilized with In-band Integration.
This boot process for non-API integrated systems is identical to the process as
described above; only the Serial Overlord will not load this time because there is no
API integration in this case.
How to Change Selected Mode
If it is necessary to change the selected mode, (after the entire booting procedure
has been completed), follow the procedure below:
♦
Expand the Service Overlord, and exit.
Once the programs have been stopped,
♦
Go to Windows Explorer Program and double click the Folder: ‘ata’.
Once you have found a file within this folder called
♦
INTEGRATED.TXT, highlight it, and then delete it.
Once the file has been deleted, reinitiate the boot up procedure.
Note: You can initiate the start up of the Service Overlord, Winsock Overlord, and Courier
Engine at this point by clicking the ‘Voice Server Startup’ icon. On a Windows 98 machine,
this icon is in the Quick Launch tray just to the right of the Start button. On a Windows NT
machine, it appears on the Windows desktop.
Содержание PanaVoice Courier
Страница 1: ...m e s s a g i n g m a d e e a s y m e s s a g i n g s y s t e m windows 98 windows n t courier manager...
Страница 15: ...PanaVoice Courier Installation Manual 14 TW O PO RT COURIER SC H EM AT IC...
Страница 16: ...PanaVoice Courier Installation Manual 15 FO U R PO R T COURIER PLUS SCH EM AT I C...
Страница 17: ...PanaVoice Courier Installation Manual 16 FO U R PO R T COURIER UMS SC H EM AT I C...
Страница 80: ...PanaVoice Courier Installation Manual 79 COURIER QUICK REFERNCE CARD...