Electrical Wiring Work
Caution
*1 : Use the cabtyre cable Power Line.
*2 : Use shielded cable for liquid tube electromagnetic valve line, showcase operation signal line and external Alarm
Line.
The shield Line connect the screw with FIL2-EN-PCB earth line when the shield Line do not ground at the
connected equipment.
*3 : Use shielded twisted pair cable for communication line.
*4 : 50 Hz 220/230/240 V ~ output
Wiring Block Diagram Example
SW1
Showcase
Operation
signal
Power
source
Power source
terminal block
Cabtyre cable (*1)
Shielded cable (*2)
Showcase Operation signal
(Non-Voltage Contact)
STP cable (Shielded Twisted Pair) (*3)
STP cable
(Shielded Twisted Pair) (*3)
User System
User
System
D-
D+
GND
D+
D-
GND
User System
(External alarm)
Shielded cable (*2)
Communication Line
Ground fault
protector
50 Hz 380/400/415V 3N~
Shielded cable (*2)
Coil for Back-up solenoid valve
...
Back-up
solenoid
Valve
signal
L1 L2 L3
External communication
terminal base
Showcase operation
terminal base
Liquid tube electromagnetic
valve terminal base (*4)
External alarm
terminal base
CR2-EN-PCB
N