7.5 The MECHANISM U replacement
1. Remove 4 screws mounting the Body B, then raise the Body B.
2. Remove 8 screws mounting the OUTER TUB COVER.
3. Remove the special screw mounting the PULSATOR.
‧
Do not remove the special screw from PULSATOR completely
then hold the screw head to pull the PULSATOR upward to remove.
4. Remove the SHAFT BUSHING
、
D SHAFT FLANGE NUT and D FLANGE WASHER B,
then pull the TUB upward to remove.
5. Turn the machine upside down.
6. Remove 4 screws(M8) mounting
the SPINNER PLATE B.
7. Remove 4 screws (M13)mounting
the MECHANISM U.
SHAFT BUSHING
D SHAFT FLANGE NUT
D FLANGE WASHER B
SPINNER PLATE B
MECHANISM U
-13-
Содержание NA-FS14G2
Страница 16: ...8 Wiring Diagram 15 ...